CMS HCAL RD for Hadron Calorimeter Upgrades Andris

  • Slides: 54
Download presentation
CMS HCAL R&D for Hadron Calorimeter Upgrades Andris Skuja University of Maryland December 5,

CMS HCAL R&D for Hadron Calorimeter Upgrades Andris Skuja University of Maryland December 5, 2003 Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

HCAL Upgrades for SLHC The Super LHC will have a design luminosity of 1035

HCAL Upgrades for SLHC The Super LHC will have a design luminosity of 1035 cm-2/sec This will be achieved by doubling the number of bunches as well as doubling the number of particles or current per bunch The result will be an increase of radiation levels everywhere. The problematic regions are HE above an η of 2 and all of HF The US groups are investigating possible upgrades of both regions Initially, readout electronics will remain as presently designed running at 40 MHz. It is felt that off-line software can sort out the correct beam crossing time to 12. 5 nsec Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Mass Reach vs energy and L VLHC Tevatron Andris Skuja – CMS HCAL Meeting

Mass Reach vs energy and L VLHC Tevatron Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

SLHC Detector Environment LHC SLHC s L 14 Te. V 1034 100 14 Te.

SLHC Detector Environment LHC SLHC s L 14 Te. V 1034 100 14 Te. V 1035 1000 Bunch spacing dt 25 ns 12. 5 ns N. interactions/x-ing ~ 20 ~ 100 d. Nch/d per x-ing ~ 100 ~ 500 Tracker occupancy Pile-up noise Dose central region 1 1 1 5 ~2. 2 10 Bunch spacing reduced 2 x. Interactions/crossing increased 5 x. Pileup noise increased by 2. 2 x if crossings are time resolvable. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

VLHC Detector Environment LHC VLHC s L 14 Te. V 1034 100 Bunch spacing

VLHC Detector Environment LHC VLHC s L 14 Te. V 1034 100 Bunch spacing dt 25 ns 19 ns N. interactions/x-ing ~ 20 ~ 25** d. Nch/d per x-ing ~ 100 ~ 250** Tracker occupancy Pile-up noise Dose central region 1 1 1 2. 5** 5** ** 130 m. B inelastic cross section, <Nch> ~ 10, <Et> = 1 Ge. V Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

CMS HCALs Had Barrel: HB Had Endcaps: HE Had Forward: HF HO HB HE

CMS HCALs Had Barrel: HB Had Endcaps: HE Had Forward: HF HO HB HE HF Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

HCAL : HE and HB HE Andris Skuja – CMS HCAL Meeting at JINR,

HCAL : HE and HB HE Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003 HB

Optical Design for CMS HCALs Common Technology for HB, HE, HO Andris Skuja –

Optical Design for CMS HCALs Common Technology for HB, HE, HO Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

HF detector 5 mm HAD (143 cm) To cope with high radiation levels (>1

HF detector 5 mm HAD (143 cm) To cope with high radiation levels (>1 Grad accumulated in 10 years) the active part is Quartz fibers: the energy measured through the Cerenkov light generated by shower particles. EM (165 cm) Iron calorimeter Covers 5 > h > 3 Total of 1728 towers, i. e. 2 x 432 towers for EM and HAD h x f segmentation (0. 175 x 0. 175) Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

HF Fiber stuffing at CERN Andris Skuja – CMS HCAL Meeting at JINR, Dubna

HF Fiber stuffing at CERN Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Issues for SLHC Radiation Damage Rate Effects Bunch ID determination Activation/access Andris Skuja –

Issues for SLHC Radiation Damage Rate Effects Bunch ID determination Activation/access Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Scintillator - Dose/Damage Current operational limit ~ 5 Mrad Andris Skuja – CMS HCAL

Scintillator - Dose/Damage Current operational limit ~ 5 Mrad Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Radiation damage to scintillators Dose per year at SLHV ECAL HCAL Barrel doses are

Radiation damage to scintillators Dose per year at SLHV ECAL HCAL Barrel doses are not a problem. For the endcaps a technology change may be needed for 2 < |y| < 3 for the CMS HCAL. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Bunch ID: CMS HB Pulse Shape 100 Ge. V electrons. 25 ns bins. Each

Bunch ID: CMS HB Pulse Shape 100 Ge. V electrons. 25 ns bins. Each histo is average pulse shape, phased +1 ns to LHC clock 12 ns difference between circled histo’s no problem with bunch ID Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Timing using calorimeter pulse shape Calculated event time (in clock cycles) 2003 Test Beam

Timing using calorimeter pulse shape Calculated event time (in clock cycles) 2003 Test Beam CMS HE Calculated event time (vertical scale) vs actual event time. CMS HE, 100 Ge. V pions. Watch pile-up though. The faster the calorimeter, the less important pile-up will be. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

HF Cerenkov Calorimeter Pulse Shape CMS HF Calorimeter 2003 Test Beam 25 ns Intrinsically

HF Cerenkov Calorimeter Pulse Shape CMS HF Calorimeter 2003 Test Beam 25 ns Intrinsically very fast Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Activation and Radiation Exposure Limits Andris Skuja – CMS HCAL Meeting at JINR, Dubna

Activation and Radiation Exposure Limits Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Activation in “forward” Region Andris Skuja – CMS HCAL Meeting at JINR, Dubna on

Activation in “forward” Region Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Activation in “endcap” Region Andris Skuja – CMS HCAL Meeting at JINR, Dubna on

Activation in “endcap” Region Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Profitable R&D Directions? Cerenkov calorimeters are rad-hard and fast good candidates for future colliders

Profitable R&D Directions? Cerenkov calorimeters are rad-hard and fast good candidates for future colliders • Quartz fiber or plate • Gas cerenkov New photon detectors low cost, small, radhard • Red-sensitive HPDs • Geiger-mode photodiodes New scintillator materials rad-hard New directions: • A number of new calorimeter concepts, some more realistic for a CMS calorimetry upgrade than others Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Scintillator R&D Approaches A B/C • Blue Tiles • Current materials • Em 408

Scintillator R&D Approaches A B/C • Blue Tiles • Current materials • Em 408 -425 nm • Blue Green WLS • WLS faster than Y 11 • EM 490 -520 nm • Use in muon system and for triggering • Areas of low/moderate radiation Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003 • Blue/Green – Green Tiles • Em 490 -510 nm • Green/Yellow WLS • EM 550 -560 nm • Benefits: • Stays short of the “crevasse” in the transmission curve. • In a region of “better” HPD QE. • Potentially good system response.

Optical Attenuation in Fiber Andris Skuja – CMS HCAL Meeting at JINR, Dubna on

Optical Attenuation in Fiber Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Example of excitation and emission measurement: Standard vs New Materials Andris Skuja – CMS

Example of excitation and emission measurement: Standard vs New Materials Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Averaged PMT pulses for a standard scintillation tile read out with multiclad WLS fibers

Averaged PMT pulses for a standard scintillation tile read out with multiclad WLS fibers Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Readout for Red Scintillator Two Reasonable Choices DEP HPD with red photocathode Advantages Fits

Readout for Red Scintillator Two Reasonable Choices DEP HPD with red photocathode Advantages Fits into existing RBX and Electronics Same power supply and control Small development costs optimize AR coating reduce dark count? Disadvantages ECAL Avalanche Photodiode Advantages 85% quantum efficiency in the red Understood and in use in CMS Cost is only $30/ch No HV, bias is 200 -500 V Disadvantages Only 7% quantum efficiency in red Cost per tube is high ($150/ch) Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003 New fiber attachment system Modified RBX design Interface to QIE Need bias and temperature control

APD & Choice of electronics ECAL electronics? QIE with modifications? Off-Axis detector may use

APD & Choice of electronics ECAL electronics? QIE with modifications? Off-Axis detector may use Pixelated APD (Ray Yarema) Comparison of HPD vs APD must be in the context of the preamplifier (noise and gain) as well as details of the APD operation: Gain, temperature, capacitance, etc… Prisca Cushman has made a number of numerical studies to compare APDs and HPDs Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Rad. Hard Scintillator Readout Upgrade A Number of investigations will be carried out in

Rad. Hard Scintillator Readout Upgrade A Number of investigations will be carried out in 2004 • Compare red sensitive HPD to APD • Design and build fiber interface to APD • Design and build interface of APD to QIE • Optimize APD operating conditions to HCAL Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

New Photodetector: Si. PMs The Silicon Photomultiplier is a Russian invention, reported by Boris

New Photodetector: Si. PMs The Silicon Photomultiplier is a Russian invention, reported by Boris Dolgoshein and colleagues at Moscow Engineering and Physics Institute, Lebedev Physical Institute, and Pulsar Enterprise (Moscow). Ref: NIM A 504 (2003) 48 - 52; NIM A 442 (2000) 187 -192 Si. PM consists of ~10**3 micropixels, size ~30 microns, with very thin (0. 75 micron) high field depletion layer. Pixels are resistively isolated, each working in limited Geiger mode as “binary” devices. The pixels signals are ganged together by aluminum strips and the summed signal is effectively analog, with dynamic range limited by the number of pixels (<~ 60% occupancy for good linearity). Gain ~10**6 Bias voltage ~25 V Broad spectral sensitivity Sees single pe, and resolves adjacent many-pe peaks with low noise Works In high magnetic fields Time resolution ~30 ps for 10 pe Size ~few mm Cost $10 in large lots ($50 in small lots) 5000 are at DESY for TESLA tile-fiber hadron calorimter Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Si. PMs Where might we use (or have used) Si. PMs? ¨ CMS HCAL,

Si. PMs Where might we use (or have used) Si. PMs? ¨ CMS HCAL, except possibly for dynamic range. Present Si. PM: ~100. If possible to increase pixel density to 2500 mm-2 and area to (1 cm)**2 ==> 6 x 10**4 dynamic range. Ease FE electronics (? ). No HV cables or supply. Cheap phototransducer. ¨ Use with Rad. Hard Green/Red tile-fiber calorimeter for ¨ High eta HE ¨ S-CMS for SLHC ¨ TOF for particle ID (a bit far-out) ¨ I will try to use them (with small blocks of scintillator) for source-garaged verifiers for all the installed CMS drivers. A nice minor use of the high-gain, low-voltage and low cost. But hand-held survey meters can do this job adequately, as we do at CDF! ¨ Use our imaginations…. . Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Si. PMs Issues: · How Rad tolerant? (and how much would that matter? )

Si. PMs Issues: · How Rad tolerant? (and how much would that matter? ) · Are pixel / device recovery times adequate for LHC (and SLHC) crossing rates? [higher pixel density ==> smaller C and Q per pixel, shorter RC. So probably worth pursuing. ] · Availability, delivery times. I’m still waiting after nearly 2 months for a few samples @$50 per device from Elena Popova, to whom Dolgoshein referred me. Dolgoshein says PULSAR will do another large production run in April. I might be able to piggyback a certain number on that order. Boris did not say what micropixel count and density. · Will PULSAR develop larger area Si. PM? higher micropixel density? Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

HE: Quartz plate and Matching WLS Fiber HE: Replace HE scintillaor in layers closest

HE: Quartz plate and Matching WLS Fiber HE: Replace HE scintillaor in layers closest to IP with quartz plate for η > 1. 5. We will also need to match the quartz light output to a WLS fiber. Iowa, Fairfield and Mississippi will do a number of trials in 2004 to see if this proposal is viable. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

HF Calorimetry • The HF detector at LHC has high-OH core, high NA, hard

HF Calorimetry • The HF detector at LHC has high-OH core, high NA, hard plastic cladding, QP fibers (quartz core plastic cladding) • Iowa group has tested fibers at LIL CERN 500 Me. V electrons NIM A 490 (2002) 444 • The HF detector will receive about 100 Mrad/year at eta=5 with accumulated dose 1 -2 Grad/10 years Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

HF Calorimetry • The HF region will have much higher doses than LHC environment

HF Calorimetry • The HF region will have much higher doses than LHC environment (1 -2 Grad/year and about 20 Grad/10 years) • For high radiation doses must use no organic materials • We will test special quartz fibers with quartz cladding. These fibers are Silica/Silica, High-OH, UV enhanced, QQ (Quartz core/ Quartz cladding) with different type of buffer materials (Acrylic, Polymide, Aluminum) with different diameters (300, 600, and 800 micron) • Fibers will be given 5 x 1017 n/cm 2, about 20 Grad (neutrons with energy > 0. 1 Me. V) in IPNS (Intense Pulsed Neutron Source) at Argonne National Laboratory • The range of 10 -50 Grad will also be available at this facility. • We will test the induced attenuation vs wavelength, transmission of Xe light in the 350 -800 nm range after irradiation. Also measure the tensile strength before and after the irradiation. • These measurements will be important for SLHC R&D for HCAL, HE, HF, ZDC, & CASTOR forward detectors. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Iowa Polymicro New Rad-hard Quartz fiber/plate project Goals: Determine if optical fibers are capable

Iowa Polymicro New Rad-hard Quartz fiber/plate project Goals: Determine if optical fibers are capable of functioning in a radiation environment 10 times the present CMS detector levels. If yes, then explore what fiber designs would be best for the CMS detector upgrade. Test candidate fiber materials –core, clad and buffer to determine suitable materials. Fabricate/Purchase test fibers with materials from step 3. Test candidate fibers for radiation hardness, mechanical and optical performance before and after irradiation. Develop preliminary fiber specifications Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Iowa Polymicro New Rad-hard Quartz fiber/plate project Fiber Designs – conduct review of the

Iowa Polymicro New Rad-hard Quartz fiber/plate project Fiber Designs – conduct review of the fiber designs suitable for the CMS application. From this review, select the focus of the design and testing activities. Focus should be on the fiber design offering the most chances of success. There are way too many fiber designs to test all. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Gas Cerenkov S/V LHC Forward Calorimeter Oleksiy Atramentov, John Hauptman, Nural Akchurin, Oesa Walker,

Gas Cerenkov S/V LHC Forward Calorimeter Oleksiy Atramentov, John Hauptman, Nural Akchurin, Oesa Walker, Rohit Nabyar • CMS Note-00 -007 “Velocity-of-light Gas …” • Jim Virdee suggested that we design a calorimeter for the SLHC • This work funded by LC R&D consortium (Luminosity monitor, 1. 4 ns, 1 MGy/y, large e/gamma backgrounds) • For SLHC, think of tungsten, hex rods, 1 meter depth, beta butylene, Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003 A t O.

Calorimeter design The Cerenkov light is generated by shower particles that cross gaps between

Calorimeter design The Cerenkov light is generated by shower particles that cross gaps between absorber elements. e- • Shower particles co-move with the Cherenkov light as two overlapped pancakes. The width of these pancakes is about 12 ps. • Inside surfaces must be highly reflective at grazing incidence. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Gas Cherenkov Calorimeter: • The Cherenkov photon signal exits the calorimeter volume at the

Gas Cherenkov Calorimeter: • The Cherenkov photon signal exits the calorimeter volume at the velocity of light Gas has index of refraction n = 1+ , ( 10 -3), therefore Cherenkov angle is small and energy threshold for electrons is high • Decay products from radioactivation of the calorimeter mass are below Eth and therefore invisible • A calorimeter made wholly of gas and metal cannot be damaged by any dose of radiation. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Photon Production of Cherenkov photons by 10 Ge. V electron transversing 2 mm gas

Photon Production of Cherenkov photons by 10 Ge. V electron transversing 2 mm gas conduits in Pb (a simulation) Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Geometries: now being simulated – G 3 and G 4 • Tubes – reflecting

Geometries: now being simulated – G 3 and G 4 • Tubes – reflecting on inside • Hex rods – reflecting on outside • “Lasagna” separated functions of absorber material and reflecting surface • Other geometries … Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

DREAM Calorimetry: DREAM Prototype (Upstream) 16. 2 cm Andris Skuja – CMS HCAL Meeting

DREAM Calorimetry: DREAM Prototype (Upstream) 16. 2 cm Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003 The detector is made from 4 mm X 4 mm copper tubes with a 2. 5 mm dia hole in them. There are 19 hexagonal towers (38 Readout channels). There are 5580 copper tubes total. The detector weighs 1030 kg. 2 m deep copper is ~10 interaction lengths. Effective rad. length is 20. 10 mm and the Moliere rad is 20. 35 mm

Dual. Readout = Scintillator + Quartz 69. 3% Cu, scintillating Quartz fiber 9. 4%,

Dual. Readout = Scintillator + Quartz 69. 3% Cu, scintillating Quartz fiber 9. 4%, Cherenkov 12. 6% and air is 8. 7% 3 scintillating and 4 clear fibers per hole. Scintillator and the quartz fiber bundles are readout separately with R 580 PMTs. There are 270 tubes per tower. Flat-to-flat measures 72 mm and contains >93% EM shower. Scintillating 38 PMTs are housed in a fiber readout box behind the detector. Wratten SCSF-81 J Kuraray, QP Polymicro, PJR-FB 750 Toray. 3 filter on scintillators. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

100 Ge. V Pions Scintillator(rms/mean)=12. 3% Quartz(rms/mean)=19. 0% S(e/pi)=1. 22 Q(e/pi)=1. 56 Andris Skuja

100 Ge. V Pions Scintillator(rms/mean)=12. 3% Quartz(rms/mean)=19. 0% S(e/pi)=1. 22 Q(e/pi)=1. 56 Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003 Q(e/h) ~5 S(e/h) ~1. 4

Energy Resolution (100 Ge. V pions) The scintillating section of the detector measures 100

Energy Resolution (100 Ge. V pions) The scintillating section of the detector measures 100 Ge. V pions with 12. 3% resolution before correction. Once the fluctuations in the EM energy deposition is removed using the information from the quartz section, the hadronic energy resolution improves. After this correction, the energy resolution improves dramatically to 2. 6%. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003 Preliminary

Remarks The combination of scintillator and clear fibers gives a good handle to measure

Remarks The combination of scintillator and clear fibers gives a good handle to measure the electromagnetic fraction for each event which can be used to improve hadronic energy resolutions significantly. If the beam energy is known, like test beams, the energy resolution can be improved by a factor of ~45. But this assumes the particle energy is already known. Beware. If, on the other hand, Ebeam is treated as unknown, the improvement is ~2 -3. Still a big factor. At the limit, the energy resolution for electrons and the pions need to be the same once this source of fluctuation is removed. Analysis continues. Interesting but probably not applicable for a CMS upgrade Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

PPAC – a Rad Hard Detector Hadron The light color is solid metal. Detectors

PPAC – a Rad Hard Detector Hadron The light color is solid metal. Detectors that sample the shower are shown in darker color. Detector near front end is for EM shower Some forward-angle calorimeters for the LHC will receive huge amounts of radiation, ~100 Grad. Need detector to be fast, simple, and radiation hard. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Iowa PPAC - a radiation hard detector Three flat plates, separated by 2 mm

Iowa PPAC - a radiation hard detector Three flat plates, separated by 2 mm Middle plate at high voltage Outer plates hold atmospheric pressure Filled with 10 -40 torr of a suitable gas Timing resolution better than 300 ps Will test energy and time resolution at the Advanced Photon Source (APS) at Argonne A simple and reliable device for sampling showers from hadrons and photons. For highest radiation levels must be made with no organic materials Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Iowa PPAC - a radiation hard detector This PPAC detector concept can be developed

Iowa PPAC - a radiation hard detector This PPAC detector concept can be developed as a candidate for luminosity monitor, HF and ZDC at SLHC. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Iowa PPAC - a radiation hard detector Planned tests with double PPAC • Test

Iowa PPAC - a radiation hard detector Planned tests with double PPAC • Test with EM showers using 80 ps bunches of 7 Ge. V electrons from the Advanced Photon Source, at Argonne National Laboratory • Test with low energy hadron showers using the 120 Ge. V proton test beam at Fermilab Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

PPAC vs. Scintillating tile A radiation hard PPAC could be made as a drop

PPAC vs. Scintillating tile A radiation hard PPAC could be made as a drop in replacement for a scintillating tile in HE. It would fit in the same space and produce a similar (but faster) signal Front End electronics would have to be redesigned Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Iowa/Fairfield Secondary Emission Sensor Modules for Calorimeters Basic Idea: A Dynode Stack is an

Iowa/Fairfield Secondary Emission Sensor Modules for Calorimeters Basic Idea: A Dynode Stack is an Efficient High Gain Radiation Sensor High Gain & Efficient (yield ~1 e/mip for Cs. Sb coating) Compact (micromachined metal<1 mm thick/stage) Rad-Hard (PMT dynodes>100 GRads) Fast Simple SEM monitors proven at accelerators Rugged/Could be structural elements (see below) Easily integrated compactly into large calorimeters low dead areas or services needed. SE Detector Modules Are Applicable to: - Energy-Flow Calorimeters - Polarimeters - Forward Calorimeters Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Iowa/Fairfield Secondary Emission Sensor Modules for Calorimeters Basic SEM Calorimeter Sensor Module Form: “A

Iowa/Fairfield Secondary Emission Sensor Modules for Calorimeters Basic SEM Calorimeter Sensor Module Form: “A Flat PMT without a Photocathode”: - The photocathode is replaced by an SEM film on Metal. Stack of 5 -10 metal sheet dynodes in a metal “window”-ceramic wall vacuum package about 5 -10 mm thick x 10 -25 cm square, adjustable in shape/area to the transverse shower size. Sheet dynodes/insulators made with MEMS/micromachining techniques are newly available, in thicknesses as fine as ~0. 1 mm/dynode Ceramic wall thickness can be ~2 mm, moulded and fired from commonly available greenforms (Coors, etc. ) Outer electrodes (SEM cathode, anode) can be thick metal, serving as absorber and structural elements. Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Iowa/Fairfield Secondary Emission Sensor Modules for Calorimeters Schematic of SEM Calorimeter Sensor Module Andris

Iowa/Fairfield Secondary Emission Sensor Modules for Calorimeters Schematic of SEM Calorimeter Sensor Module Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003

Acknowledgements Thanks to Tiziano Camporesi, Jim Freeman and Dan Green Slides were contributed by

Acknowledgements Thanks to Tiziano Camporesi, Jim Freeman and Dan Green Slides were contributed by many of our US CMS Collaborators • • Prisca Cushman Virgil Barnes Yasar Onel Dave Winn Lucien Crimaldi John Hauptman Nural Akchurin Randy Ruchti and Dan Karmgard I invite all members of CMS HCAL to contribute to the upgrade of our calorimeter for SLHC Andris Skuja – CMS HCAL Meeting at JINR, Dubna on December 5, 2003