Outline: 1. Analyze Axial Loading Scenarios a. Determine Live Load b. Analyze/Develop Floor Framing

Outline: 1. Analyze Axial Loading Scenarios a. Determine Live Load b. Analyze/Develop Floor Framing i. ii. Joists Beams/Girders c. Analyze/Develop Supports for Floor Framing 2. Analyze Lateral Loading Scenarios a. Anchored Structure or Free Standing 3. Unanswered Key Questions

Floor Framing Beam A Joist • 2” x 8” Grade No. 2 lumber is

Floor Framing Beam A Joist • 2” x 8” Grade No. 2 lumber is for each joist. • Joists will be suspended using face-mounted joist hangers Beam B • Beams will span the entire width of the garage and be supported using columns underneath each end. • Microllam LVL is assumed to be used at the start of the analysis Beam C Beam D

Floor Framing Dead Load: • Dead Load from ¾” Plywood 2. 5 psf •

Floor Framing Dead Load: • Dead Load from ¾” Plywood 2. 5 psf • Table Look up[1] 2. 4 psf • Validation using generic density calculation 2. 5 psf • Dead Load from 2”x 8” Joist (16” O. C. ) 3. 5 lbs/ft • Validation using generic density calculation • Dead Load from one LVL Beam 6. 1 lbs/ft • Table from Weyerhaeuser Microllam LVL Beam Design and Specification[2] Live Load: • Mezzanine Live Load is categorized as Light Storage [3] 125 psf

Floor Framing Joist Analysis: • Tributary Width[1]: TW = ½(distance to adjacent beam on

Floor Framing Joist Analysis: • Tributary Width[1]: TW = ½(distance to adjacent beam on the right) + ½(distance to adjacent beam on the left) TWjoist = 16 in *(1 ft/12 in) = 1. 33 ft • Dead Load (in lbs/ft) is found by adding the dead load for the Plywood and the Joists DL = (2. 5 psf)* TWjoist +2. 3 lbs/ft DL = 5. 625 lbs/ft • The Live Load (in lbs/ft) is taken at: LL = 125 psf * TWjoist LL = 166. 25 lbs/ft

Floor Framing Joist Analysis: • Assumptions: 1. No Live Load Reductions – Because the

Floor Framing Joist Analysis: • Assumptions: 1. No Live Load Reductions – Because the Live Load is greater than 100 psf, no live load reduction formulas can be used 2. Uniform Load on each joist 3. Joists are created using a roller and pin connection. 4. Length of Joist (L = 5. 64 ft) 5. Joist Material: Hem-Fir Grade #2 Lumber

Floor Framing Joist Analysis: FBD of Joist: w = LL + DL Rj

Floor Framing Joist Analysis: FBD of Joist: w = LL + DL Rj

Floor Framing • Moment, M Shear, V Rj Mmax x L/2

Floor Framing • Moment, M Shear, V Rj Mmax x L/2

Floor Framing •

Floor Framing •

Floor Framing •

Floor Framing •

Floor Framing •

Floor Framing •

Floor Framing • h N. A. b Joist Cross Section

Floor Framing • h N. A. b Joist Cross Section

Floor Framing •

Floor Framing •

Floor Framing •

Floor Framing •

Floor Framing •

Floor Framing •

Floor Framing Joist Analysis: • Analyze Deflection: For a distributed load, the maximum deflection

Floor Framing Joist Analysis: • Analyze Deflection: For a distributed load, the maximum deflection can be found as follows: Deflection, y w L Dead Load Deflection: L/2 x

Floor Framing Joist Analysis: • Analyze Deflection: Live Load Deflection : NOTE: The Live

Floor Framing Joist Analysis: • Analyze Deflection: Live Load Deflection : NOTE: The Live Load Deflection is less than the Live Load Deflection Limit Incremental Long Term Deflection: NOTE: k=Creep Factor = 0. 5 (Chosen assuming Dry Service Conditions) NOTE: ΔTL is less than the Incremental Long Term Deflection Limit Live Load Deflection and Incremental Long Term Deflection were both found to be under their corresponding limits; therefore, the 2” x 8” joist passed the deflection test.

Floor Framing Joist Analysis: • Analyze Bearing Stress: Find the adjusted allowable bearing stress

Floor Framing Joist Analysis: • Analyze Bearing Stress: Find the adjusted allowable bearing stress (or compression stress perpendicular to the grain): Find the minimum required bearing length (Recall, Rmax = Rj = 485 lbs): The design uses face mounted joist hangers where the to of the joist is flush with the top of the beam/girder. Therefore, the team is preparing to use Simpson Strong-Tie joist hangers (LUS 26 for 2 x 8 joists). These joist hangers provide a bearing length of 1. 75” The maximum load these joist hangers can handle is 865 lbs, which is much greater than the reaction force. The 2 x 8 joist passes the bearing stress test.

Floor Framing Beam A Joist Recall: • Beams will span the entire width of

Floor Framing Beam A Joist Recall: • Beams will span the entire width of the garage and be supported using columns underneath each end. Beam B • Microllam LVL is assumed to be used at the start of the analysis (Two LVLs are used for Beams B & C) Beam C • Beam analysis follows same steps as joist analysis Beam D

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment for each Beam A: TWA = 70. 25 in *(1 ft/12 in) = 2. 9 ft w = LL + DL DL = (2. 5 psf)* TWA +2. 3 lbs/ft + 6. 1 lbs/ft = 15. 65 lbs/ft RA L LL = 125 psf * TWA = 362. 5 lbs/ft RA

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment for each Beam A: Moment, M Shear, V RA Mmax x L/2

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment for each Beam B: TWB = 70. 7 in *(1 ft/12 in) = 5. 9 ft w = LL + DL DL = (2. 5 psf)* TWB +2. 3 lbs/ft + 12. 2 lbs/ft = 29. 25 lbs/ft RB L LL = 125 psf * TWB = 737. 5 lbs/ft RB

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment for each Beam B: Moment, M Shear, V RB Mmax x L/2

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment for each Beam C: TWC 1 = 35. 6 in *(1 ft/12 in) = 3 ft TWC 2 = 78 in *(1 ft/12 in) = 6. 5 ft w 2 = LL 2 + DL 2 DL 1 = (2. 5 psf)* TWC 1 +2. 3 lbs/ft + 12. 2 lbs/ft = 22 lbs/ft w 1 = LL 1 + DL 1 DL 2 = (2. 5 psf)* TWC 2 +2. 3 lbs/ft + 12. 2 lbs/ft = 30. 75 lbs/ft LL 1 = 125 psf * TWC 1 = 375 lbs/ft LL 2 = 125 psf * TWC 2 = 812. 5 lbs/ft RC 1 L 2 L RC 2

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment for each Beam C: Moment, M Shear, V RB Mmax L/2 x x L/2

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment for each Beam D: TWD = 42. 4 in *(1 ft/12 in) = 3. 5 ft w = LL + DL DL = (2. 5 psf)* TWD +2. 3 lbs/ft + 6. 1 lbs/ft = 17. 15 lbs/ft RD L LL = 125 psf * TWD = 437. 5 lbs/ft RD

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment

Floor Framing Beam Analysis: • Find the Maximum Shear and the Maximum Bending Moment for each Beam D: Moment, M Shear, V RD Mmax x L/2

Floor Framing Beam Analysis: • Using the values of the maximum moment and the

Floor Framing Beam Analysis: • Using the values of the maximum moment and the maximum shear, an analysis similar to that of joists can be followed to verify/select beams. • • Look at Bending Stress Requirements Look at Shear Stress Requirements Look at Deflection Requirements Look at Bearing Stress Requirements • Comments: • Adding more supports under each beam may allow for different material to be used, but it will limit the space underneath the platform. • The Beam material is currently being optimized for best available usage.

Supports • Columns are used to support the end of each beam • The

Supports • Columns are used to support the end of each beam • The Columns are connected to a 2 x 6 that makes contact with the floor • The Columns are also connected to (2) 2 x 4 that make contact with the beams • Parallam PSL is assumed to be used at the start of the analysis for the columns supporting two LVLs at once (Beam B and Beam C) • This analysis looks at axial loaded columns (Lateral is still needed)

Supports Column Analysis: • Assumptions: 1. No Live Load Reductions – Because the Live

Supports Column Analysis: • Assumptions: 1. No Live Load Reductions – Because the Live Load is greater than 100 psf, no live load reduction formulas can be used 2. Point loads are used axially along the column 3. Both the Top and Bottom of the column are considered pin connected 4. Unbraced Length of Column (L = 5. 3 ft) 5. Joist Material: Parallam PSL

Supports Column Analysis: • First, find the Adjusted Allowable Compression Stress (Parallel to grain)

Supports Column Analysis: • First, find the Adjusted Allowable Compression Stress (Parallel to grain) 1 • To find the adjusted allowable compression stress, you must solve the four equations to the right after verifying the slenderness ratios are less than 50 • Because both ends of the column are assumed to be pinned, the effective Length, le = Ke * L where Ke is equal to one (This is the worst case scenario) • c = 0. 9 for glulam 2 3 4

Supports Column Analysis: • First, find the Adjusted Allowable Compression Stress (Parallel to grain)

Supports Column Analysis: • First, find the Adjusted Allowable Compression Stress (Parallel to grain) Verify each Slenderness Ratio is less than 50 Find Emin’ Find the critical buckling stress

Supports Column Analysis: • First, find the Adjusted Allowable Compression Stress (Parallel to grain)

Supports Column Analysis: • First, find the Adjusted Allowable Compression Stress (Parallel to grain) Find Fc* Find Cp Find Fc’

Supports Column Analysis: • Second, the allowable compression load capacity • Each Parallam PSL

Supports Column Analysis: • Second, the allowable compression load capacity • Each Parallam PSL column can be loaded up to 7891 lbs before buckling occurs due to an axial compressive force. • Similar analysis can be run for the smaller columns to find the most efficient design.

Next Steps/Questions: • Can the mezzanine be anchored into the supporting structure? • Anchors

Next Steps/Questions: • Can the mezzanine be anchored into the supporting structure? • Anchors would be placed into side walls (and potential back wall) to prevent lateral movement and offer stability • If the mezzanine needs to be free standing: • Knee Braces will need to be added to each post. This requires unique analysis. • Sheathing would need to be added to the columns/post to restrict lateral movement. • Although they are not very strong, an analysis needs to be conducted on Lateral Loads to our system. • Fireproofing the structure may be a requirement from the city • A permit may be required (city originally said no, but Subject Matter Experts think one will be needed). • If a permit is required, there is a chance this mezzanine analysis will need to be signed/stamped by a Professional Engineer.

References 1. Aghayere, Abi O. , and Jason Vigil. Structural Wood Design. Boca Raton,

References 1. Aghayere, Abi O. , and Jason Vigil. Structural Wood Design. Boca Raton, FL: CRC, 2017. Print. 2. Http: //www. woodbywy. com/author/kschultz/. "Microllam LVL Beams. " Weyerhaeuser. N. p. , 2016. Web. 07 Dec. 2016. 3. Stalnaker, Judith J. , and Ernest C. Harris. Structural Design in Wood. New York: Chapman & Hall, 1997. Print.