Thermionic emission If a tungsten filament is heated
- Slides: 35
Thermionic emission • If a tungsten filament is heated to about 2000 o C, some of the electrons have sufficient kinetic energy to escape from the surface of the wire. • This effect is called thermionic emission. • It is quite easy to imagine this if we think about a metal wire as a lattice of ions in a sea of free electrons. In effect we are boiling the electrons off.
Thermionic Diode • In the vacuum tube there are two electrodes • Cathode -ve Anode +ve • When the filament is switched on electrons start to flow from the cathode the tungsten filament and are attracted to the anode • You need a vacuum as the electrons would collide with the gas particles. Also the filament would burn up
Deflection tube • The electron gun consists of a heated filament/cathode and an anode with a hole in it. • This produces a narrow beam of electrons • The screen is coated with a fluorescent material which glow when electrons strike it.
Deflection Tube
Defection by an electric field • The negatively charged electrons are attracted towards the positive plate.
Deflection tube • In a magnetic field the electron is deflected depending on the direction of the magnetic field - Use Lenz’s left hand rule.
Cathode Ray Tubes Thermionic emission was the starting point for Joseph John Thomson to produce his cathode ray tube (CRT) in 1897, the descendants of which we used to see every day, before TFT (thin film transistor) TV sets became more common. • Now do question 1 page 243
Using an Oscilloscope
Learning Objectives n To know what an oscilloscope is and how it works. n To know how to measure the pd of alternating current and direct current. n To know how to measure the frequency of an alternating current.
Cathode Ray Oscilloscope
Definition n From the specification book: - n An oscilloscope consists of a specially made electron tube and associated control circuits. n The electron gun emits electrons towards a fluorescent screen light is emitted when electrons hit the screen this is what we see.
Tube Photograph
Electron Gun Photograph
Tube Diagram y plates - amplifier anode x plates - timebase heater supply - + H. T. supply fluorescent screen
Cathode Ray Oscilloscope (CRO) Time base Display Y-gain My tie Channel 1 Channel 2
How does it work? n An oscilloscope consists of a specially made electron tube and associated control circuits. n An electron gun at one end of the glass tube emits electrons in a beam towards a fluorescent screen at the other end of the tube. n Light is emitted from the spot on the
How does it work? n When no p. d. is applied across the plates the spot on the screen is stationary. n If a pd is applied across the X-plates the beam of electrons is deflected horizontally and the spot moves across. n pd across Y-plates spot moves up and down.
Reading the CRO 1 Peak-to. Peak voltage Time Period (ms) To get the time period you need to measure this distance and convert it to time by multiplying by the time base setting
Oscilloscope Controls n The x-plates are connected to a time base circuit which is designed to make the spot move across the screen in a given time then back again much faster. a bit like a trace on a heart monitor. n The y-plates are connected to the Y-input and this causes the spot to move up or down depending on the input pd.
electron gun produces a beam of electrons summary y plates anode heater supply light produced on the screen by electron beam x plates a p. d. across the y - + deflects the plates vertically H. T. trace supply a p. d. across the x plates deflects the phosphor trace horizontally screen
Oscilloscope Controls n The gain sets the scale for the y-axis, normally in volts per cm. n The time base sets the scale for the x-axis, normally in ms per cm. n Recall that frequency can be calculated from the period from the graph using:
Displaying a waveform 1. The time base • The X-plates are connected to the oscilloscope’s time base circuit. • This makes the spot move across the screen, from left to right, at a constant speed. • Once the spot reaches the right hand side of the screen it is returned to the left hand side almost instantaneously. • The X-scale opposite is set so that the spot takes two milliseconds to move one centimetre to the right. (2 ms cm-1). NTNU Oscilloscope Simulation KT Oscilloscope Simulation
Gain and Time-Base Controls
Displaying a waveform 2. Y-sensitivity or Y-gain • The Y-plates are connected to the oscilloscope’s Y-input. • This input is usually amplified and when connected to the Yplates it makes the spot move vertically up and down the screen. • The Y-sensitivity opposite is set so that the spot moves vertically by one centimetre for a pd of five volts (5 V cm-1). • The trace shown appears when an alternating pd of 16 V peakto-peak and period 7. 2 ms is connected to the Y-input with the settings as shown. NTNU Oscilloscope Simulation KT Oscilloscope Simulation
Peak Voltage Peak p. d. = 3 Divisions x 1. 0 m. V/div = 3. 0 m. V
Period & Frequency period = 4. 0 divisions x 1. 0 ms/div = 4. 0 ms frequency = 1 / period frequency = 1 / 0. 004 s frequency = 250 Hz
Measuring d. c. potential difference All three diagrams below show the trace with the time base on and the Y-gain set at 2 V cm-1. Diagram a shows the trace for pd = 0 V. Diagram b shows the trace for pd = +4 V Diagram c shows the trace for pd = -3 V. NTNU Oscilloscope Simulation KT Oscilloscope Simulation
Measuring a. c. potential difference Let the time base setting be 10 ms cm-1 and the Y-gain setting 2 V cm-1. In this case the waveform performs one complete oscillation over a horizontal distance of 2 cm. Therefore the period of the waveform is 2 x 10 ms period = 20 ms as frequency = 1 / period frequency = 1 / 0. 020 s = 50 Hz. NTNU Oscilloscope Simulation KT Oscilloscope Simulation The peak-to-peak displacement of the waveform is about 5 cm. Therefore the peak-to-peak pd is 5 x 2 V Peak-to-peak pd = 10 V
Self Test
The oscilloscope ‘graph’ scales Y-AXIS Potential difference +V Scale determined by the ‘Y-GAIN’ control 0 V Typical setting: 1 V / cm -V cm squares X-AXIS Time Scale determined by the ‘X-GAIN’ or ‘TIME-BASE’ control Typical setting: 0. 1 s / cm
Question 1 Measure the approximate period, frequency and peakto-peak pd of the trace opposite if: Time base = 5 ms cm-1 Y-gain = 5 V cm-1 period = 50 ms / 6 ≈ 8. 7 ms frequency ≈ 115 Hz peak-to-peak pd ≈ 20 V
Question 2 Measure the approximate period, frequency and peak pd of the trace opposite if: Time base = 2 ms cm-1 Y-gain = 0. 5 V cm-1 period = 20 ms / 12 ≈ 1. 7 ms frequency ≈ 600 Hz peak pd ≈ 1. 3 V
Question 3 The trace shows how a waveform of frequency 286 Hz and peak-to-peak pd 6. 4 V is displayed. Suggest the settings of the time base and Y-gain amplifier. The period of a wave of frequency 286 Hz = 1/285 = 0. 0035 s = 3. 5 ms One complete oscillation of the trace occupies 7 cm. Therefore time base setting is 3. 5 ms / 7 cm ≈ 0. 5 ms cm-1 The peak-to-peak displacement of the trace is about 3. 7 cm. Therefore the Y-gain setting is 6. 4 V / 3. 7 cm ≈ 2 V cm-1
Application n Measuring the speed of ultrasound. n Set up the oscilloscope so that the time base circuit triggers a transmitter to send out a pulse of ultrasonic waves. n The receiver can be connected to the Yinput of the oscilloscope so that the waveform can be seen on the screen when it is detected.
Internet Links • Oscilloscope - basic display function NTNU • Oscilloscope Simulation - by KT • Lissajous figures - Explore Science • Lissajous figures - by KT
- Thermionic emission current
- Deflection of electron in electric field formula
- Why filament is heated in cro
- Thoriated tungsten filament
- A certain light bulb has a tungsten filament
- Power-law (gamma) transformation
- Spektrometer massa
- When an iron ring is heated the hole becomes
- Calcium carbonate carbon dioxide
- In an industrial process nitrogen is heated to 500k
- Water expands when heated
- How many times can thermoplastics be heated and shaped
- Specific heat of sugar solution
- Heated attendant parking meaning
- Political demonstrations on american campuses have abated
- Gelatinisation
- Why is ceramic wool heated in cracking
- A piece of metal is heated then submerged in cool water
- Heated hollow glass
- Phenol + fecl3
- The triatomic gas is heated isothermally
- Thermal expansion in liquids
- Tungsten fabric
- Tungsten-186
- Introduction of gas welding
- Tungsten inclusion in rt film
- Wave superposition worksheet
- Kode warna untuk elektroda tungsten tipe ewla-1 adalah
- Tungsten replicator open source
- Tungsten streak
- Tungsten melting pot
- Tungsten invoice portal
- Tungsten atomic structure
- Tungsten replicator
- Welding positions
- Tungsten replicator