Siemens Energy Automation Inc sinamics SINAMICS S 120

  • Slides: 18
Download presentation
Siemens Energy & Automation, Inc. sinamics SINAMICS S 120

Siemens Energy & Automation, Inc. sinamics SINAMICS S 120

Automation and Drives Applied Drive of the Future SINAMICS S 120 Overview Stand Alone

Automation and Drives Applied Drive of the Future SINAMICS S 120 Overview Stand Alone Drives Multi-Axis Drives Controllers Safety Integrated SINAMICS S 120 The new drive system for demanding drive applications in machine building and plant construction 2

Automation and Drives A Truly Complete Family SINAMICS S 120 Overview Stand Alone Drives

Automation and Drives A Truly Complete Family SINAMICS S 120 Overview Stand Alone Drives The SINAMICS-Family Multi-Axis Drives Controllers Safety Integrated 3

Automation and Drives SINAMICS Engineering Workbench SINAMICS S 120 Multi-Axis Drives SIZER Project Stand

Automation and Drives SINAMICS Engineering Workbench SINAMICS S 120 Multi-Axis Drives SIZER Project Stand Alone Drives Pre-Sales Overview Workbench (uniform look&feel) Controllers Safety Integrated STARTER Post-Sales stand-alone or STARTER integrated In SCOUT, STEP 7, or Drive ES Parts list n Order

Automation and Drives SINAMICS S 120 System overview AC supply SINAMICS S 120 Overview

Automation and Drives SINAMICS S 120 System overview AC supply SINAMICS S 120 Overview Stand Alone Drives Multi Axis Drive Control Unit Line Modules SINAMICS S 120 Motor Modules Single Axis Drive Control Units Multi-Axis Drives Controllers Safety Integrated D/C components Electronic options Motors

Automation and Drives SINAMICS S 120: product variants / power range SINAMICS S 120

Automation and Drives SINAMICS S 120: product variants / power range SINAMICS S 120 DC/AC drives (Common DC bus) Overview Stand Alone Drives Multi-Axis Drives Controllers for multiple axis applications AC/AC drives for single axis applications 2 – 125 HP in Booksize-Format 0. 25 – 125 HP in Blocksize-Format 125 – 1600 HP in Chassis-Format 125 – 400 HP in Chassis-Format Safety Integrated

Automation and Drives SINAMICS S 120 AC/AC Components SINAMICS S 120 Overview Single-axis drives

Automation and Drives SINAMICS S 120 AC/AC Components SINAMICS S 120 Overview Single-axis drives consist of two components Control Unit + Power Module Stand Alone Drives Multi-Axis Drives CU 310 DP (Profibus) CU 310 PN (PROFINET) Controllers Safety Integrated PM 340 CUA 31 Compatibility of CUs and PM -> reduction in versions

Automation and Drives AC/AC Framesize Overview SINAMICS S 120 Overview Stand Alone Drives Multi-Axis

Automation and Drives AC/AC Framesize Overview SINAMICS S 120 Overview Stand Alone Drives Multi-Axis Drives Controllers Safety Integrated D 18, 5 -30 k. W B 2, 2 -4 k. W A 230: 0, 12 -0, 75 k. W 460 V: 0, 37 -1, 5 k. W C 7, 515 k. W E 37 -45 k. W F 55 -90 k. W FX 110 -132 k. W Starting with a complete Power Range GX 160 -250 k. W

Automation and Drives Multi-axis Drives SINAMICS S 120 Multi-axis drives consist of at least

Automation and Drives Multi-axis Drives SINAMICS S 120 Multi-axis drives consist of at least three components n Line module (supply) Overview n Motor module (power unit) Stand Alone Drives n Control unit for the control of several drives Multi-Axis Drives Controllers Safety Integrated n Only one field bus connection to a higher-level control is required for the whole axis line-up Communication for all components is performed via a uniform interface: DRIVE-CLIQ

Automation and Drives DRIVE-CLi. Q Flexible Backplane SINAMICS S 120 Overview Stand Alone Drives

Automation and Drives DRIVE-CLi. Q Flexible Backplane SINAMICS S 120 Overview Stand Alone Drives Multi-Axis Drives Controllers Safety Integrated SMC 30 SMC 20 Digital/analog periphery Motor with DRIVE-CLi. Q interface Motor without DRIVE-CLi. Q interface DRIVE-CLi. Q encoder Conventional encoder All drive-related components are connected to SINAMICS S 120 via DRIVE-CLi. Q

Siemens Energy & Automation, Inc. Combining booksize and chassis units Production Machines n DRIVE-CLi.

Siemens Energy & Automation, Inc. Combining booksize and chassis units Production Machines n DRIVE-CLi. Q and the unified software architecture enable combined operation of the various SINAMICS S 120 designs Line Module Chassis Motor Modules Chassis Control Unit Single axis w/ CUA 31 Motor Modules Booksize and chassis units may be combined within a single line -up | 12

Automation and Drives Innovative Machine Designs SINAMICS S 120 P 350 Overview Stand Alone

Automation and Drives Innovative Machine Designs SINAMICS S 120 P 350 Overview Stand Alone Drives Multi-Axis Drives Controllers Frame Size A w/ CUA 31 Modular Machine Safety Integrated CU 320 + LM + MM Multi-axis system combined with single axis power modules to form a modular machine

Automation and Drives Line Modules SINAMICS S 120 Basic Line Modules Overview n Non-regulated

Automation and Drives Line Modules SINAMICS S 120 Basic Line Modules Overview n Non-regulated Stand Alone Drives Smart Line Modules Multi-Axis Drives n Non-regulated rectifier/regenerative unit Controllers Safety Integrated Active Line Modules n Regulated DC link rectifier/regenerative unit • Reduced harmonics • Line fault tolerant • Higher performance • Better motor utilization • Rectification of 1. 6 vs. 1. 35 Line Modules supply the energy for the DC-link

Automation and Drives Motor Modules – Booksize Design SINAMICS S 120 Single Motor Modules

Automation and Drives Motor Modules – Booksize Design SINAMICS S 120 Single Motor Modules Overview n for Stand Alone Drives Double Motor Modules Multi-Axis Drives rated output currents up to 200 A n Space saving version for two motors n for rated output currents up to 18 A Controllers Safety Integrated Motor Modules supply the motors with energy from the DC -link

Automation and Drives Example of CU 320 Control Module SINAMICS S 120 Overview Stand

Automation and Drives Example of CU 320 Control Module SINAMICS S 120 Overview Stand Alone Drives CU 320 control unit 8 parameterizable digital inputs 8 parameterizable bi-directional digital inputs/outputs (of which 6 are high-speed inputs) Multi-Axis Drives Fastening lug Integrated side receptacles Controllers Safety Integrated PROFIBUS interface Compact. Flash Card - Stores parameters - Defines performance option Option slot for expanding the interfaces, e. g. TB 30, CBC 10 4 2 -color status LEDs 3 measuring sockets which help you in commissioning Parameterized as either a Servo or Vector Controller

Automation and Drives Commonality between Control Systems SINAMICS S 120 Overview Stand Alone Drives

Automation and Drives Commonality between Control Systems SINAMICS S 120 Overview Stand Alone Drives Multi-Axis Drives Central control unit The control unit is the ONLY difference between the various control systems. Control Units SINAMICS CU 320 Controllers Safety Integrated SIMOTION D 445 D 435 D 425 SINUMERIK NCU 730 NCU 720 NCU 710

Automation and Drives Safe standstill (SH) SINAMICS S 120 Protection against unexpected start-up of

Automation and Drives Safe standstill (SH) SINAMICS S 120 Protection against unexpected start-up of the drive n Impulses of the drive are safely “deleted” Overview n Torque-generating energy supply is safely disconnected Stand Alone Drives n Two-channel control Later also via PROFIsafe Multi-Axis Drives P 24 Safe standstill on power module Controllers Safety Integrated P 24 No torquegenerating energy Safe standstill on CU 320 (one terminal for one or more drives) Checkback signal from CU 320 Advantages: No switching devices for “electric OFF“ or no problematic contactors between converter and motors. n The DC-link “can stay alive“. n

Automation and Drives Safe brake control (SBC) SINAMICS S 120 Brake control directly at

Automation and Drives Safe brake control (SBC) SINAMICS S 120 Brake control directly at the motor module – two-channel, monitored (for Booksize devices) Overview n Both switched between 24 V and ground Stand Alone Drives n Brake cable integrated in motor cable no PLC output required Multi-Axis Drives Controllers Power module Safety Integrated Monitoring and Control If there is a control fault, the brake will remain fully functionable! 24 V supply 24 V B+ +24 V Channel 1 Monitoring M Diagnostics M B- Channel 2 Motor module Motor with integrated brake U 2 V 2 W 2 Power plug Power cable Load