This is a photographic template – your photograph should fit precisely within this rectangle. Electrical Solutions & Services LVS Product Overview Wim Porte Manager Product Marketing Electrical Sector EMEA Region October 2012 © 2008 Eaton Corporation. All rights reserved.

Capitole 40 MCC - Features & Benefits • Proven reliability, verified by testing according

Capitole 40 MCC - Features & Benefits • Proven reliability, verified by testing according to IEC-61439 • Easy to modify during operation • Suitable to communicate with Process Control Systems • Arc Free protection of your personnel • Type tested according to IEC 61641 2 2

Capitole 40 MCC - Product program • Air Circuit Breakers • Magnum • NRX

Capitole 40 MCC - Product program • Air Circuit Breakers • Magnum • NRX • Moulded Case Circuit Breakers Air Circuit Breaker NRX • Series G • NZM • Fused Combination Switches Switch Disconnector Dumeco • QSA • QP • Switch Disconnector • Dumeco 3 3

Capitole 40 MCC - Applications • Petrochemical industry • Gas and oil exploration •

Capitole 40 MCC - Applications • Petrochemical industry • Gas and oil exploration • Process industry • Power stations • Critical Power - Data Centers • Water treatment plants 4 4

Capitole 40 MCC - Technical data Operating voltage, max. : Frequency: 690 V 50/60

Capitole 40 MCC - Technical data Operating voltage, max. : Frequency: 690 V 50/60 Hz Main busbar system Rated insulation voltage, max. : Rated current, max. : Rated short-time current, max. : Rated peak withstand current, max. : 1000 V 6300 A 100 k. A-1 s 220 k. A Distribution busbar system Rated insulation voltage, max. : Rated current, max. : Rated short-time current, max. : Rated peak withstand current, max. : 1000 V 1420 A 80 k. A-1 s 176 k. A 5 5

Capitole 40 MCC - Features & benefits • Type Tested Designs according to IEC

Capitole 40 MCC - Features & benefits • Type Tested Designs according to IEC 61439 • Fixed, Plug-In and Withdrawable offering • Both Fused (QSA) and with MCCB’s (NZM, PKZ) for motor starters and feeders • Designed around Eaton devices • Optional Arc. Free design with insulation and segregation of the bus bars – following criteria's 1 -7 of the IEC 61641 • Using quotation tool “Bid Manager” to generate single line, arrangement drawing and complete bill of material 6 6

Capitole 40 P – Features and Benefits • Plug-in technology • Compact design •

Capitole 40 P – Features and Benefits • Plug-in technology • Compact design • Form 4 a • High Density due to natural ventilation • With ACB’s, MCCB’s and fused solutions 7 7

Capitole 40 P - Applications • Hospitals • Universities • Data Centers • Commercial

Capitole 40 P - Applications • Hospitals • Universities • Data Centers • Commercial Buildings • Industry 8 8

Capitole 40 P – Technical data Main Busbar Data Rated current Rated short-time withstand

Capitole 40 P – Technical data Main Busbar Data Rated current Rated short-time withstand A k. A/s 6300 100/1 Vertical distribution busbar data Rated current Rated short-time withstand A k. A/s 2000 50/1 IP 31 or 41 Form 4 a/ 4 b Plug-in Degree of protection Form of separation Outgoing Units 9 9

Clink II i-MCC – Features & benefits • Intelligent MCC • Less downtime •

Clink II i-MCC – Features & benefits • Intelligent MCC • Less downtime • Less expensive (reduced hardware and wiring costs) • Reduced costs (more efficient engineering, testing and maintenance) • Better authorization (no screwdrivers but passwords) • Proven technology (large installed base) 10 10

Clink II i-MCC – System configuration SCU = Starter Control Unit FCU = Feeder

Clink II i-MCC – System configuration SCU = Starter Control Unit FCU = Feeder Control Unit LCU = Local Control Unit CIU 1 = Central Interface Unit CIU 2 = Redundant Central Interface Unit --- = Redundant network 11 11

Clink II i-MCC – Applications • Petrochemical industries • Gas and oil exploration •

Clink II i-MCC – Applications • Petrochemical industries • Gas and oil exploration • Process industries • Power stations • Critical Power - Data Centers • Water treatment plants 12 12

Clink II i-MCC – Open System • Open interface: contactor brand independent • Open

Clink II i-MCC – Open System • Open interface: contactor brand independent • Open internal network: Device. Net (ODVA certified) • Open communication to process control: Modbus/Profibus/Ethernet 13 13

Power Xpert® CX – Features & Benefits • Operator Friendly • Verified by testing

Power Xpert® CX – Features & Benefits • Operator Friendly • Verified by testing • Ergonomical innovative design • Focused on safety of personnel • Mechanical test position • Modular design • Easy to upgrade/ exchange 18 18

Power Xpert® CX – Product program • Air Circuit Breakers • Magnum • NRX

Power Xpert® CX – Product program • Air Circuit Breakers • Magnum • NRX • Moulded Case Circuit Breakers • NZM • Motor Starter Units • PKZ / PKE Motor-protective circuit-breakers • DILM Contactors 19 19

Power Xpert® CX - Applications • Water Industries • Food and Beverage • Infrastructure

Power Xpert® CX - Applications • Water Industries • Food and Beverage • Infrastructure • Industrial Facilities • Steel Industries 20 20

Power Xpert® CX – Technical data Main Busbar Data Rated current Rated short-time withstand

Power Xpert® CX – Technical data Main Busbar Data Rated current Rated short-time withstand A k. A/s 5000 100/1 Vertical distribution busbar data Rated current Rated short-time withstand A k. A/s 2000 80/1 IP 31 / 55 Form 3 b/ 4 b Fixed / Withdrawable Degree of protection Form of separation Outgoing Units 21 21

M 2 L distribution board – Features & Benefits • MV, LV and Transformer

M 2 L distribution board – Features & Benefits • MV, LV and Transformer integrated solution • Minimizing expensive LV cabling • Reduction in energy losses • Reduction of dedicated switchrooms • Reduction in assembly time 22 22

M 2 L distribution board – Product Program • Low Voltage Systems • Capitole

M 2 L distribution board – Product Program • Low Voltage Systems • Capitole 20 • Capitole 40 • Medium Voltage Systems • Magnefix • Xiria • SVS • Transformers • Dry type up to 1600 k. VA 23 23

M 2 L-distribution board - Applications • Hospitals • Universities • Data Centres •

M 2 L-distribution board - Applications • Hospitals • Universities • Data Centres • Commercial Buildings • Industry 24 24

Otonet – Features & Benefits Automatic Transfer System • Monitoring main voltage(s) • Reliable,

Otonet – Features & Benefits Automatic Transfer System • Monitoring main voltage(s) • Reliable, flexible and “easy to use” • Controls LV or MV breakers • Generator brand/type independent Standard transfer schemes for switching over: • Reliable hardware • Through dark / or with sync check • Transformer / Generator Incomer (+Bus tie) • Including generator control (start / stop) 25 25

Otonet - Applications • Hospitals • Universities • Data Centres • Commercial Buildings •

Otonet - Applications • Hospitals • Universities • Data Centres • Commercial Buildings • Industry 26 26

Busbar LP, MP & XP – Features & Benefits • Ranges for low power

Busbar LP, MP & XP – Features & Benefits • Ranges for low power (LP), medium power (MP) and high power (XP) • Range from 25 – 6300 A • Comply with IEC 61439 -2 • Flexible and easy to install • Highly styled design 27 27

Busbar - Applications • Hospitals • Universities • Data Centres • Commercial Buildings •

Busbar - Applications • Hospitals • Universities • Data Centres • Commercial Buildings • Industrial Facilities 28 28

Eaton Low Voltage Systems Capitole 20 Clink II Power Xpert® CX Otonet Capitole 40

Eaton Low Voltage Systems Capitole 20 Clink II Power Xpert® CX Otonet Capitole 40 Busbars LP, MP & XP 29 29