Microscale Tensile Tester Update 3 ChengChieh Chao Maryam

  • Slides: 12
Download presentation
Micro-scale Tensile Tester Update # 3 Cheng-Chieh Chao Maryam Ziaei-Moayyed Ranadeep Bhowmick Sujay Bangalore

Micro-scale Tensile Tester Update # 3 Cheng-Chieh Chao Maryam Ziaei-Moayyed Ranadeep Bhowmick Sujay Bangalore Ramachandra ME 342 Spring 2006 Prof. Beth Pruitt

SU-8 dogbones SU-8 5 ( 5 µm) SU-8 2 ( 2 µm) • Mask

SU-8 dogbones SU-8 5 ( 5 µm) SU-8 2 ( 2 µm) • Mask for the dog-bone structure (with the correct polarity/alignment) in hand • Processing: Substrate Pretreat Coat Soft bake [ 65 o. C 1 min; 95 o. C larger time to ensure that wafer does not stick to mask] Expose using Karlsuss Si substrate SU-8 2 ( 2 µm) 8 s; using 4 exposures of 2 sec duration SU-8 5 ( 5 µm) 25 s; using 10 exposures of 2. 5 sec duration Al substrate SU-8 2 ( 2 µm) 7. 2 s; using 3 exposures of 2. 4 sec duration SU-8 5 ( 5 µm) 22. 5 s; using 9 exposures of 2. 5 sec duration Post exposure bake Develop

Images of the Su-8 dog-bones Characterization: 200 µm Thickness Exposure time Stiction 20 µm

Images of the Su-8 dog-bones Characterization: 200 µm Thickness Exposure time Stiction 20 µm

Dog-bone Release 1. Omnicoat Release Steps: Coat release layer (~ 30 nm thickness) Bake

Dog-bone Release 1. Omnicoat Release Steps: Coat release layer (~ 30 nm thickness) Bake @ 200 o. C Coat, expose, post expose bake, develop SU-8 structures Strip SU-8 Immerse in Remover PG (NMP) at 80 o. C Disadvantage: Su-8 peels off but cannot retain its structural integrity and forms a gel like substance

Dog-bone Release 2. Schematic of the set-up for Al dissolution Electrolytic Release cathode anode

Dog-bone Release 2. Schematic of the set-up for Al dissolution Electrolytic Release cathode anode electrolytic solution Pt foil sacrificial Al layer Steps Si wafer SU-8 dog-bone • Al layer of 500 nm thickness deposited on Si wafer • SU-8 is deposited/exposed/developed on top of the Al layer • Place another Si/glass wafer on top of the wafer with the dogbone structure to help prevent disintegration of Su 8 since its hydrophobic • The sacrificial layer of Al removed by anodic dissolution ( 2 M Na. Cl in H 20; 0. 5 V) • Waiting for the results !!

Actuator : Revised Process flow

Actuator : Revised Process flow

Actuator Characterization:

Actuator Characterization:

Cell phone camera Image of the Actuator

Cell phone camera Image of the Actuator

Good exposure(1. 6 µm PR) Bad exposure(7 µm PR)

Good exposure(1. 6 µm PR) Bad exposure(7 µm PR)

Sensing Circuit

Sensing Circuit

Things to be done 1. Testing to be done with AD 7746 Evaluation Board

Things to be done 1. Testing to be done with AD 7746 Evaluation Board 2. Start on the SOI wafers Pad-etch still needs to be characterized 3. Training required on : wire- bonding wafer saw nano-vac 4. Back up plan for CPD for releasing comb drive from the oxide layer

Thank You

Thank You