TriTech Genesys Can fulfill all of your manifold

  • Slides: 13
Download presentation
Tri-Tech & Genesys Can fulfill all of your manifold requirements Designed for today, ready

Tri-Tech & Genesys Can fulfill all of your manifold requirements Designed for today, ready for tomorrow

Tri-Tech Medical Manual, Mechanical and Analog Auto Changeover n n Manual – TSD, RSP,

Tri-Tech Medical Manual, Mechanical and Analog Auto Changeover n n Manual – TSD, RSP, RWP, TMD manual manifolds TMC Series Analog cyl x cyl – U. S. TML Series Analog pbv x pbv (vapor) – U. S. Auto. Switch Series Analog cyl x cyl – U. S.

Why Manifolds?

Why Manifolds?

Because Jim Says So? n n n n Safety Uninterrupted supply of gas Cost

Because Jim Says So? n n n n Safety Uninterrupted supply of gas Cost Regulatory requirement Increase flow of liquid to vapor or limited flow gas i. e. N 2 O/CO 2 to necessary volume 50 SCFH per cylinder at room temperature Liquid cylinders N 2 & Oxy - 375 SCFH, N 2 O 80 SCFH, CO 2 – 110 SCFH Simplified ordering and delivery for both the gas supplier and end user

Tri Tech Manual Manifolds TSD – Simple Duplex. Light industrial, Dental And Veterinary applications

Tri Tech Manual Manifolds TSD – Simple Duplex. Light industrial, Dental And Veterinary applications RSP/RWP – Simplex. Industrial, Dental, Veterinary, High Pressure Backup to NFPA Liquid Cyl. System TMD – Manual Duplex. Industrial, Dental, Veterinary.

New Auto. Switch – Fully Automatic Manifold n n n Works with high or

New Auto. Switch – Fully Automatic Manifold n n n Works with high or low press. 3. 5” Wide X 6” High Fully automatic changeover controlled and indicated mechanically Optional remote alarm capable Delivery range up to 400 psi (dependent on regulator) Ideal veterinary & limited dental clinic applications

Genesys™ Manifolds TMCU TMLU Fully Automatic Changeover Manifold System for Medical or Industrial Use

Genesys™ Manifolds TMCU TMLU Fully Automatic Changeover Manifold System for Medical or Industrial Use Priced at Semi-Automatic Changeover Cost.

New Analog Fully Automatic Industrial & Medical Manifolds n n Model TMCU cylinder x

New Analog Fully Automatic Industrial & Medical Manifolds n n Model TMCU cylinder x cylinder Industrial (single line regulator) Medical NFPA 99 compliant (with dual line regulators) Circuit board triggers secondary in use alarm (only). Pressure switches may be used for additional 2 required master alarms (if for level 1 or 2 medical installation)

Portable Bulk? We can handle it!

Portable Bulk? We can handle it!

New Analog Fully Automatic Industrial & Medical Manifolds n n Model TMLU portable bulk

New Analog Fully Automatic Industrial & Medical Manifolds n n Model TMLU portable bulk x portable bulk (vapor withdrawl) Industrial (single line regulator) Medical NFPA 99 compliant (with dual line regulators) Circuit board triggers secondary in use alarm (only). Pressure switches may be used for additional 4 required master alarms (if for level 1 or 2 medical installation)

How to Order exactly what you need TMCU SERIES - FULLY AUTOMATIC CHANGEOVER SYSTEM

How to Order exactly what you need TMCU SERIES - FULLY AUTOMATIC CHANGEOVER SYSTEM FOR HIGH PRESSURE CYLINDERS HOW TO ORDER Final Line Regulation TMCU = HP Cylinders 1 = Single line regulator 2 = Dual line regulators Cabinet Type 1 = standard Gas Service AI = Air / Medical Air AR = Argon CD = Carbon Dioxide HE = Helium NT = Nitrogen NO = Nitrous Oxide OX = Oxygen Delivery Pressure 1 = 50 psi 2 = 125 psi 3 = 180 psi # of Cylinders or Vessels on Left Bank Header Configuration S = Staggered B – Standard V - Vertical Crossover Flow & Heater Options # of Cylinders L = Standard flow or Vessels on Right Bank H = High flow W = With heaters (see chart above for flow capacities)

How to Order exactly what you need TMLU SERIES - FULLY AUTOMATIC CHANGEOVER SYSTEM

How to Order exactly what you need TMLU SERIES - FULLY AUTOMATIC CHANGEOVER SYSTEM FOR LIQUID CYLINDER/PORTABLE BULK TANKS HOW TO ORDER Final Line Regulation TMLU = Portable Bulk Delivery Pressure 1 = Single line regulator 2 = Dual line regulators Cabinet Type 1 = standard Gas Service AI = Air / Medical Air AR = Argon CD = Carbon Dioxide HE = Helium NT = Nitrogen NO = Nitrous Oxide OX = Oxygen 1 = 50 psi 2 = 125 psi 3 = 180 psi # of Cylinders Vessels on Left Bank Flow & Heater Options L = Standard flowor H = High flow W = With heaters Header Configuration S = Staggered B – Standard V - Vertical Crossover # of Cylinders Vessels on Right Bank

Tri Tech, a full line of manifolds for most common gas applications Tri Tech

Tri Tech, a full line of manifolds for most common gas applications Tri Tech would like to be your full time manifold supplier. Our products, service and innovations are second to none. So whatever your next project may be, or an opportunity to sell a manifold to compliment your gas sales arises, call us!