GIF++ ENVIRONMENTAL AND GAS SENSORS UPDATE August 12, 2015 Contact: stefano. bianco@lnf. infn. it

GIF++ ENVIRONMENTAL AND GAS SENSORS UPDATE August 12, 2015 Contact: stefano. bianco@lnf. infn. it Laboratori Nazionali di Frascati dell’INFN Stefano, Ernesto, Roberto RPC crew: Nicolas, Salvador, Fabiola, Gabriella et al CSC crew: Katerina, Armando Frascati crew: Luciano, Alessandro, Daniele, Luigi, Davide, Saleh Bologna crew: Marino, Alessandro, Davide Bari Crew: Anna et al rs nso e S f i /G c i l b u P : https i. ce k i w t // rn bin / i k i w. ch/t MS C / w /vie 1

 • Monitoring (for both atmospheric and gases) • Pressure p • Temperature T

• Monitoring (for both atmospheric and gases) • Pressure p • Temperature T • Relative humidity H • Modular architecture • Six gas sampling points: • GASBOX 101, 102, 103, 104, 105, 106 • Four atmospheric sampling points • ENVBOX 201, 202, 203, 204 2

 • Twiki page is now in public WEB – • https: //twiki. cern.

• Twiki page is now in public WEB – • https: //twiki. cern. ch/twiki/bin/view/CMSPublic/Gif. Sensors Email helpdesk from a CERN registered email account – gifsensors-helpdesk@cern. SPAMNOT. ch QR code labels to be updated and replaced 3

TEMPERATURE ABSOLUTE CALIBRATION • All GASBOX and ENVBOX tested in Frascati and CERN –

TEMPERATURE ABSOLUTE CALIBRATION • All GASBOX and ENVBOX tested in Frascati and CERN – Compared to reference thermometers (FLUKE and DIGITRON) • Calibration at CERN suggests an offset <TBOX-TREF> ~ 0. 6 o. C attributed to the CAEN ADC. FINAL RESULTS COMING UP 4

HUMIDITY ABSOLUTE CALIBRATION • All GASBOX and ENVBOX tested in Frascati and CERN –

HUMIDITY ABSOLUTE CALIBRATION • All GASBOX and ENVBOX tested in Frascati and CERN – Compared to reference RH hygrometer (DIGITRON) with air • No offset within design resolution • GASBOX 102 compared at CERN by Ernesto with Dew Point Hygrometer flushed with RPC gas – Calibration at CERN suggests a very large scale factor RHBOX / RHDPH ~ 0. 6 • Plan: – Check two more GASBOXEs not in use – Check DPH with air 5

6

6

LABELS (TBD) AND NAMING • GASBOX 101, 102, 103, 104, 105, 106 • ENVBOX

LABELS (TBD) AND NAMING • GASBOX 101, 102, 103, 104, 105, 106 • ENVBOX 201, 202, 203, 204 (no P sensor) 7

GASBOX and ENVBOX (centimeters) The 15 GASBOX 8 CERN grou radia p is go

GASBOX and ENVBOX (centimeters) The 15 GASBOX 8 CERN grou radia p is go ing t tion o pro shiel Desi vide ding gn in s. prog ress 22 22 11 ENVBOX 8

Environmental Sensors: specifications T, H sensor PCMini 70 Michell p sensor TSA Gefran CAEN

Environmental Sensors: specifications T, H sensor PCMini 70 Michell p sensor TSA Gefran CAEN ADC 3801 Stainless steel housing for use with F- 9

Gas & Environmental sensors CAEN ADC INTEGRATED IN DCS SENSORS CONTROL UNIT SENSORS BOX

Gas & Environmental sensors CAEN ADC INTEGRATED IN DCS SENSORS CONTROL UNIT SENSORS BOX 30 m CABLE 10

Some more pictures GIF sensors back (env connectors) GIF sensors Rack Front GIF sensors

Some more pictures GIF sensors back (env connectors) GIF sensors Rack Front GIF sensors CAEN Crate 11