Wire Scanner WS Acquistion System cable tester for
Wire Scanner (WS) Acquistion System cable tester for safe installation R. De Monte, M. Ferianis, S. Cleva, S. Grulja ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019 2
WS ACQ SYS block diagram ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019 3
WS Acquisition System: Wire current readout block diagram ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019 4
Simplified Block Diagram for Analogue Front End (AFE) V 3. 0 Analog Front End TWO IDENTICAL STAGES for Horizontal and Vertical RL 4 @ Low gain RL 1 * Wide range CM filter RL 3 ² + +- 5 VCC_HV +-5 VCC_BF Single End to Differential 1 step variabile gains Differential TX Buffer In vacuum HIGH gain Small range RL 1 * coax cable Triax cable CM Filter + * Var gain 2 pos with relay +-5 VCC_BF RL 2 RL 3 High voltage (+- 100 VDC) Floating Ground ² : RL 3 represent an optional connection in case of troubles with cables connections/impedance matching ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019 Signals and power from Back End unit @: 10 u. A generator RL 4
Back End BLOCK DIAGRAM 5: 1 ATT Differential RX Buffer 5: 1 ATT To ADC board From AFE/OFE Differential RX Buffer 5: 1 ATT ESS BI Forum Warsaw AC main Vout -5 V Sense-5 V +5 VCC_HV Gnd float Vout +5 V Sense+5 V -5 VCC_HV Vout -5 V Sense-5 V -5 Vreg +5 Vreg AC main -5 Vreg Relays Bu. FFER +HV gen 0. 1 XS 5 -P 5 To ADC board From AFE/OFE 5: 1 ATT +5 Vreg REF-02 5: 1 ATT Differential RX Buffer Gnd signal +5 VCC_BF Vout +5 V Sense+5 V To 8 AFE Relays Optional 2 nd Buffer unit in OFE BE mod Differential RX Buffer +5 VCC_BF To AFE/OFE To control various functions like HV control and check, gain and self test controls using an Ethernet port to the CPU, a PIC 18 F 2510 µ controller connected to a XT- PICO –XXL has been choosed. SPI 16 bit DAC -HV gen 0. 1 XS 5 -N 5 PIC 18 F 2510 u. Controller Level translator XT- PICO -XXL ETHERNET adc Raffaele De Monte, oct 22 -24, 2019 6
Analog Front End and Back End This year, in JUNE, we have completed the Site Acceptance Test (SAT) for the Analog Front Ends and associated Back Ends, teaming and training ESS Staff (C. Derrez))). ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019
BLOCK DIAGRAM FOR ACCEPTANCE TEST HTML OUTPUT Agilent 33220 A Generator Opto-coupled current generator EPICS WS Digital acquisition system 1 1 2 3 4 Back End (BE) Analog Front End (AFE) ? DB 25 cable DB 9 cable 05 jul 2018 - Page 8 ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019
Connections in schematics… ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019
Connections in practice… ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019
Cable tester working principle 5 V 1 KΩ 100Ω 1 KΩ 5 V-0 X 13 Pulse 5 V 100Ω X 13 100Ω DB Connector 10 bit ADC X 13 10 bit ADC LONG RUN CABLES 13 x 1 KΩ ESS BI Forum Warsaw 1 KΩ Termination unit Raffaele De Monte, oct 22 -24, 2019
Hardware summary The cable tester is made using: • One PIC 18 F 4455 -I/P µcontroller 40 Pin DIP @ 8 MHz • Two TTL drivers 74 HC 138 • One Lantronix Xport serial to ethernet ESS BI Forum Warsaw Single power supply 9 to 12 VDC 150 m. A Max Raffaele De Monte, oct 22 -24, 2019
Cable Test Flow chart Start test Disable All Outputs All readings off? Y NO Set n out Relative IN value OK? NO Y Others IN off? Y Increment n NO NO Test Failed All pins? (5 or 13) Y Test Passed ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019
The Cable tester hardware Cable tester box front view Cable tester box rear view Cable testing Termination unit ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019
Operation Modes Two modes of operations: Mode 1: Check cables without details: does NOT require other devices (PC) Using a simple push putton, following the steps described on the label, after the first short press, the DB 9 connector check start. The related green LED starts to blink: after the cable test if is passed, the LED reamain in ON state, otherwhise the LED is starting to bilnk fast. At the next short press, the DB 25 check is starting and the results are visible on the associated LED, blinking if failed, ON if check is passed. Mode 2: Check cables with detailed informations, it requires a lan connection and a telnet terminal. It works with push button AND with these commands: ? This Help DF reboot T 9 Automtic test of DB 9 connector T 5 Automtic test of DB 25 connector Sn Select n OUT (for particular, detailed tests) R Read All ADC ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019
User interface outputs ESS Wire Scanner Cables tester V 1. 04 11/10/2019 Elettra Sincrotrone Trieste SCp. A Connect the Termination Board (remote side) with BOTH CABLES Connect ONE CABLE AT ONCE to the tester box (this side) Commands: ? This Help DF reboot T 9 Test DB 9 connector T 5 Test DB 25 connector T 9 Sn Select n OUT Start test on DB 9 Connector R Read All ADC DB 9 Conn pair 9 -4 OK: ADC=2662 DB 9 Conn pair 8 -3 OK: ADC=2657 DB 9 Conn pair 7 -2 OK: ADC=2652 DB 9 Conn pair 6 -1 OK: ADC=2652 DB 9 Conn pair shell-5 OK: ADC=2662 T 5 DB 9 Connector OK Start test on DB 25 Connector DB 25 Conn pair 2 -14 OK: ADC=2667 DB 25 Conn pair 3 -15 OK: ADC=2662 DB 25 Conn pair 4 -16 OK: ADC=2657 DB 25 Conn pair 5 -17 OK: ADC=2657 DB 25 Conn Error: INPUT TOO HIGH (UNCONNECTED? ? ) ON SELECTED CHANNEL Out. Pin=6 In. Pin=18 ADC=4997 DB 25 Conn pair 7 -19 OK: ADC=2662 DB 25 Conn pair 8 -20 OK: ADC=2662 DB 25 Conn pair 9 -21 OK: ADC=2662 DB 25 Conn pair 10 -22 OK: ADC=2672 DB 25 Conn pair 11 -23 OK: ADC=2662 DB 25 Conn pair 12 -24 OK: ADC=2662 DB 25 Conn pair 13 -25 OK: ADC=2662 DB 25 Conn pair 1 -shell OK: ADC=2667 DB 25 Connector NOT OK: 1 errors We will implement some machine readable format to acquire these data also from the ESS EPICS control system ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019
Label on the top box ESS BI Forum Warsaw Raffaele De Monte, oct 22 -24, 2019
Suggestions and comments are welcome! Thank you for your attention ESS BI Forum Warsaw Raffaele De Monte, Oct 23, 2019