US LHC Accelerator Research Program bnl - fnal- lbnl - slac Test status of

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Test status of ten-stacks of insulation systems for LQ. R. Bossert March 17, 2010 1

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Ten stacks are

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Ten stacks are being done to compare the amount of insulation between turns for various insulation systems to be used for TQ/LQ coils. Measurements shown represent the space between two turns as shown below. The “nominal” amount of insulation between turns is 10 mils (254 microns). This represents the amount assumed to be taken up by the 5 mil sleeve used traditionally for TQ/LQ coils. 2

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Initially, all 10

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Initially, all 10 stacks were cured in a fixed cavity at 25 MPa. This procedure was meant to replicate the coil curing procedure “ 35 MPa” 10 MPa 25 MPa Curing Cavity 10 stack fixture 3

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Coil and Ten

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Coil and Ten Stack Measuring Fixtures with respective inserts 4

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Double 3 mil

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Double 3 mil eglass with 1/16 gaps 45 % overlap 3 mil eglass 40% overlap 3 mil eglass 5 mil S 2 Sleeve 5

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Machine measures stack

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Machine measures stack size with respect to a steel master. “Insulation between turns” is calculated by: (Measured insulated stack size/10) – bare cable size. Cured coils were also measured on the same fixture with respect to a steel master with a different insert. The insulation between turns for coils is calculated by: [(Measured insulated coil size – metal parts and extra 5 mil glass)/34 turns] bare cable size. Sleeve is specified as 5 mil S 2 glass. All other systems use 3 mil e-glass with various types of wrap as noted in “stack type” 6

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Note: Compression of

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Note: Compression of insulation using sleeve according to these measurements is about 36% (163 / 254). 7

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Measured cable insulation

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Measured cable insulation thickness of Ten Stacks and TQ coils. Nominal uncompressed insulation size Nominal bare cable size Compression of insulation as measured on coils is 2%-10%, but on ten stacks it is 36%. 8

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Due to some

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Due to some anomalies as well as the extremely small differences between samples, a new method of curing stacks was tried. 35 MPa 25 MPa Shim Original method: All stacks cured using the same cavity size. Shim was set by pressing standard “sleeve” stack to 25 MPa. New method: All stacks cured at a pressure of 25 Map without shim (allowing cavity size to vary). 9

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Cable Insulation Thickness

US LHC Accelerator Research Program bnl - fnal- lbnl - slac Cable Insulation Thickness of Various Ten Stacks 10