Tyco Fire & Security Technical Trainings DSC Power. Series Intruder Panels Chapter 1: Overview

Tyco Fire & Security Technical Trainings DSC Power. Series Intruder Panels Chapter 1: Overview

Objectives • After successfully completing this training the student should be able of: –

Objectives • After successfully completing this training the student should be able of: – Know the Power. Series Intruder Panels the main features – Know the Power. Series Intruder Panels specification – Know the compatible Devices and their specifications

Product Categories Control Panels, Keypads & Modules Sensors & Accessories Communications

Product Categories Control Panels, Keypads & Modules Sensors & Accessories Communications

DSC range of Panels Wireless panels Hybrid panels Alexor 1. 2 EN Power 1616

DSC range of Panels Wireless panels Hybrid panels Alexor 1. 2 EN Power 1616 Alexor V 1. 2 EN Power 1832 SCW-9045 Power 1864 SCW-9047 Maxsys PC- 4020

Panels approvals DSC Panels Certifications SCW-9045 Grade 1 SCW-9047 Grade 1 Alexor 1. 2

Panels approvals DSC Panels Certifications SCW-9045 Grade 1 SCW-9047 Grade 1 Alexor 1. 2 Grade 2 Alexor V 1. 2 Grade 2 Power 1616 Grade 2 Power 1832 Grade 2 Power 1864 Grade 2 Maxsys Grade 1

Device approvals DSC Products Certifications Wireless devices Grade 2 GS-2060 Grade 2 TL-260 GS

Device approvals DSC Products Certifications Wireless devices Grade 2 GS-2060 Grade 2 TL-260 GS Grade 2 Keypads Grade 2 Keypad with wireless receiver Grade 2 LC-Series indoor Grade 2 LC-Series outdoor Grade 1

Power. Series – Capacities PC 1616 PC 1832 PC 1864 9045 Alexor On-Board Zones

Power. Series – Capacities PC 1616 PC 1832 PC 1864 9045 Alexor On-Board Zones 6 8 8 2 2 Hardwired Zones 16 32 64 2 2 Wireless Zones 32 32 32 2 way wireless devices No No Yes Keypad Zone Support Yes Yes No No On-Board PGM 2 2 4 2 2 Keypads Supported 8 8 8 No 4 Partitions 2 4 8 1 1 User Codes 47 +Master Codes 71 +Master Codes 94 +Master Codes 16 16 Voice Dialer No No Yes IP/GPRS compatible Yes Yes No Yes AUX Current 700 m. A 200 m. A

Specifications • Zone Configuration: • • • 6 on-board zones (PC 1616) 8 on-board

Specifications • Zone Configuration: • • • 6 on-board zones (PC 1616) 8 on-board zones (PC 1832/PC 1864) 34 different zone definitions 3 different zone configurations – Normally Closed, Single EOL, Double EOL Hardwired zone expansion – Method#1 – Zone Expanders (PC 5108) – Method#2 – Keypad Zones – Method#3 – Addressable (PC 5100) Not sold in the EU. • Wireless Zone Expansion (RF 5132 -433, RF 5108 -433, RFK 55 XX Keypads) • Partitions: • 2 Partitions – PC 1616 • 4 Partitions – PC 1832 • 8 Partitions – PC 1864

Specifications • User Access Codes: • PC 1616 – 48 Access Codes • PC

Specifications • User Access Codes: • PC 1616 – 48 Access Codes • PC 1832 – 72 Access Codes • PC 1864 – 95 Access Codes • 2 Duress Codes • 1 System Master Code • 2 Supervisory Codes • Programmable access code attributes • Bell Output: • • Rated at 12 vdc, 700 ma (2 A Max. , short term) PTC Protected Supervised Steady or Pulse Output

Specifications • Memory: • CMOS EEPROM • Retain system programming and status even after

Specifications • Memory: • CMOS EEPROM • Retain system programming and status even after AC and battery loss • Bell Circuit: • Rated at 12 vdc, 700 ma (2 A Max. , short term) • PTC Protected • Supervised • Steady or Pulse Output • Communicator: – • • • Support of current major alarm communication format including: SIA Contact ID Pulse

Power. Series Control Panels PC 1616, 1864 & 1832 Platform: • Full hybrid systems

Power. Series Control Panels PC 1616, 1864 & 1832 Platform: • Full hybrid systems (wireless, wired and loop detectors) • Single architecture for global feature set and module expansion • Backward compatibility of all Power. Series modules • Conventional Power programming retained (*8) required No retraining • Revised Installation manual for ease and speed of install • GPRS & IP alarm transmission compatibility. • 2 different programming way (LCD keypad)

Power. Series Control Panels PC 1616, 1864 & 1832 Platform: • Same programming for

Power. Series Control Panels PC 1616, 1864 & 1832 Platform: • Same programming for all the panels (Alexor and 9045 included) • DLS 2002, DLS 4 and DLS 5 compatibility. • All the range of keypads, RS-232, PSTN, IP and GPRS programming. • One way Wireless devices full compatibility with all the panels. • Possibility to program one zone like Key switch to set/unset the panel. • Possibility to install up to 8 different keypads. – Mix LED, Programmable LCD and Fixed LCD on the Same System

Power. Series Control Panels • Communications • Automatic SIA Format, Automatic Contact ID and

Power. Series Control Panels • Communications • Automatic SIA Format, Automatic Contact ID and Pulse, fast format • Pager Format, residential format • Supports T-LINK LAN/WAN IP Communicator • Supports GPRS communicators. • Supports SMS reporting. • Phone Line and Siren Circuit Supervision • Fuseless Design • PTC Protection for Bell, Battery and AUX Output

Common Features • 700 m. A Auxiliary supply • 37 zone types including night

Common Features • 700 m. A Auxiliary supply • 37 zone types including night arming, day zone, auto-verify fire • 32 PGM types (added zone follow and true partition support) • 12 communication formats • Delinquency Code – Non Activity Code • 500 Event buffer • 8 keypad support • Programmable Day Light Savings • CP-01/Ro. HS EN grade 2 Compliant • PDD 6662 compliant version 4. 13

Keybus • All Modules Connect to Panel Via 4 Wire Bus • Modules can

Keybus • All Modules Connect to Panel Via 4 Wire Bus • Modules can be Home Run, Daisy Chained or T-Tapped • Modules can be Connected up to 1, 000 Feet(300 mtrs) from the Panel • Less Wire, Less Wire Pulls, Less Cost

False Alarms • Cross Zoning: 2+ alarms required • Auto Verified Fire Zone, Delayed

False Alarms • Cross Zoning: 2+ alarms required • Auto Verified Fire Zone, Delayed Fire Zone – 2 Detections to Generate Alarm – Zone type 29 – PGM type 03 • Exit Delay Restart • Transmission Delay: Delays alarm transmission • Additional Reporting Codes – Alarm Cancelled: Opening After Alarm – Recent Closing: arming with alarm in memory

PC 1616 • PC 1616 supports: – 2 partitions – 16 hardwired: 1 PC

PC 1616 • PC 1616 supports: – 2 partitions – 16 hardwired: 1 PC 5108 plus Keypads zones – 32 wireless zones (v 4. 2 and above). If hardware is also used 32 zones is the maximum. – 2 on-board PGMs (14 Max) – 47 user codes – 12 communication formats – 6 digit account code – TL/GS modules support

PC 1832 • PC 1832 supports: – 4 partitions – 32 Zones maximum between

PC 1832 • PC 1832 supports: – 4 partitions – 32 Zones maximum between Hardwired and Wireless – 2 on-board PGMs (14 Max) – 71 user codes – 12 communication formats – 6 digit account code – No activity delay arming – TL/GS modules support – Exceptional False Alarm Prevention

PC 1864 • PC 1864 supports: – 8 partitions – 64 Zones: all Hardwired

PC 1864 • PC 1864 supports: – 8 partitions – 64 Zones: all Hardwired or with up to 32 WLS zones (Zones 1 to 32) – 4 on-board PGMs (14 Max) – 94 user codes – 12 communication formats – 6 digit account code – No activity delay arming – TL/GS modules support – Exceptional False Alarm Prevention

Introducing V 4. 5 for Power. Series PC 1616/1832/1864 • Please note V 4.

Introducing V 4. 5 for Power. Series PC 1616/1832/1864 • Please note V 4. 5 is only supported by DLS IV, a new driver is now available. – CO Support – Hardwired and Wireless Detectors • For wireless CO detector WS 4913, use either V 5. 1 of the wireless receiver RF 5132 -433 or V 1. 2 of the keypads with built-in wireless receiver RFK 5500, RFK 5501, RFK 5516 or RFK 5508. – Alternate Communicator call direction options – Automatic Contact ID over GPRS – Automatic Sync for alternate communicators (account code and reporting format) – Added System Reset reporting code

Power. Series Keypads DSC KEYPAD REDESIGN Keypad Concept Refinements

Power. Series Keypads DSC KEYPAD REDESIGN Keypad Concept Refinements

Power. Series Keypads - PK 55 xx Family • Replaces the Power PC/LCD 55

Power. Series Keypads - PK 55 xx Family • Replaces the Power PC/LCD 55 xx Family • Retains all features of old Power with the following additions: – Backward compatibility of all Power. Series control panels – Wire channel – Added I/O for either PGM or Zone – AC indicator – Improved installation – 32 character zone labels (PK 5500 Z) – Global Partition Status Option (PK 5500 Z) • RF versions available on all styles of keypads • The keypad is working like wireless receiver.

Power. Series Keypads - PK 55 xx Family LED Keypads PK 5516 16 zone

Power. Series Keypads - PK 55 xx Family LED Keypads PK 5516 16 zone PK 5508 8 zone LED 5511 Z 8 zone Touch Screen PK 5590 CL Colour Touch Screen Interface • Modern, slim-line landscape keypad • Large, backlit keypad buttons • 5 programmable function keys • Input/Output terminal LCD Keypads PK 5500 Full Message Keypad RFK 5500 Full Message Keypad with Integrated Receiver

Modules – Hardwire Expansion PC 5108 8 Hardwire Zone Expander AMB-300 PIR PC 5100

Modules – Hardwire Expansion PC 5108 8 Hardwire Zone Expander AMB-300 PIR PC 5100 Addressable Expander Module AMB-500 Ceiling Mount PIR AMP-700/AMP-701 Door/Window Contacts AMS-220 Smoke Detector • Addressable 2 Wire Polling Loop • Up to 32 Zones • Detectors can be Home Run, Daisy Chained, T-Tapped AMB-600 Pet Immune PIR AMA-100 Glassbreak

Modules – Wireless Expansion RF 5132 Wireless Receiver RFK 5500 LCD with Built-In Wireless

Modules – Wireless Expansion RF 5132 Wireless Receiver RFK 5500 LCD with Built-In Wireless Receiver PC 4920 1 -Way Wireless Repeater • Increased 1 -way wireless range • Supports up to 32 Zones • Supports up to 16 Wireless Key fobs • All Detectors Fully Supervised for Communication and Low Battery • Improved signal quality between device and receiver • Interference Detection Feature • Support for maximum of 4 repeaters per system PC 5320 Multiple Wireless Receiver Module • Connect up to 4 Wireless Receivers for Larger Coverage Area • Combine both RF 5132 and RFK 5500 on the Same System • Each Receiver Supervised

Wireless PIRs 1 -way 433 MHz 868 MHz WS 4904 PW WS 8904 PW

Wireless PIRs 1 -way 433 MHz 868 MHz WS 4904 PW WS 8904 PW Wireless Pet Immune PIR detector WS 4904 W WS 8904 W Wireless PIR detector

Wireless contacts 1 -way 433 MHz 868 MHz WS 4945 W WS 8945 W

Wireless contacts 1 -way 433 MHz 868 MHz WS 4945 W WS 8945 W WS 4965 WS 8965 Tri-Zone Door/Window Contact WS 4975 W WS 8975 W Vanishing Door Contact WLS 912 L-433 W Door Contact Glassbreak Detector

Wireless life safety 1 -way 433 MHz 868 MHz WS 4913 WS 8913 WS

Wireless life safety 1 -way 433 MHz 868 MHz WS 4913 WS 8913 WS 4916 EU WS 8916 W WS 4985 WS 8985 Wireless CO Sensor (on Alexor only!) Wireless Smoke Detector Wireless Flood Sensor

Wireless fobs 1 -way 433 MHz 868 MHz WS 4938 W WS 8938 W

Wireless fobs 1 -way 433 MHz 868 MHz WS 4938 W WS 8938 W WS 4938 -2 W WS 4939 EU 1 -button panic button 2 -button panic button WS 8939 W 4 -button Key WS 4949 2 -button key WS 4969 4 -Button With Built-In Flashlight

Modules – Output Expansion PC 5200 PC 5204 PC 5208 Power Supply/Output Module Low

Modules – Output Expansion PC 5200 PC 5204 PC 5208 Power Supply/Output Module Low Current Output Module • Provides 1 Amp • Fully Supervised for AC Failure, Low Battery and AUX Output Trouble • PTC Protected • Connect up to 4 Power Supply modules in total (maximum 1 PC 5204) • Provides 1 Amp. Provides 4 Programmable, High Current Outputs. Output #1 Supervised for Siren or Strobe Connection • Fully Supervised for AC Failure, Low Battery and AUX Output Trouble. PTC Protected • Connect up to 4 Power Supply modules in total (maximum 1 PC 5204) • Provides 8 Low Current PGM Outputs

Modules – 2 way Audio Module Audio Stations PC 5961 Stand-Alone Audio Station PC

Modules – 2 way Audio Module Audio Stations PC 5961 Stand-Alone Audio Station PC 5950 Universal 2 -Way VOX Audio Verification Module PC 5964 Large Speaker Station • PC 5962 Contoured Audio Station • • • Supports both 2 -way audio VOX and push-totalk verification Supports 4 microphones and 4 speakers Silent/Listen-in functionality on hold-up alarms (activates only when an alarm occurs) User call-in feature

Modules – Communicators GS 2060 • GPRS Wireless Alarm Communicator TL 260 GS •

Modules – Communicators GS 2060 • GPRS Wireless Alarm Communicator TL 260 GS • Internet and GSM/GPRS Dual. Path Alarm Communicator

IT-100 – Features • Compatible with all Power. Series control panels • Bi-directional RS-232

IT-100 – Features • Compatible with all Power. Series control panels • Bi-directional RS-232 interface • Real-time zone status • Fully programmable • 4 -wire hook-up to KEYBUS • Enables third parties to perform virtual keypad functions • Integrated with Kantech and C·CURE 9000 access control Systems.

Kantech Embedded DSC Integration • Easy installation and integration: • Connect the IT-100 into

Kantech Embedded DSC Integration • Easy installation and integration: • Connect the IT-100 into the KT-400 for maximum integration • Connect the IT-100 into the serial port of the corporate gateway • Simple programming and uploading

Kantech Embedded DSC Integration • Receive events in real time from the intrusion panel

Kantech Embedded DSC Integration • Receive events in real time from the intrusion panel • Generate historical and quick reports • Video triggers based on intrusion panel events • Alarm acknowledgements • Graphic integration • View status of zones and partitions • Operations on partitions • Use virtual keypad for programming • Single or multiple partition arming and disarming • From single reader or multiple readers and a KT-400 • From manual operators from workstation

Summary 1. How many zones can be programmed on each power panel? 2. How

Summary 1. How many zones can be programmed on each power panel? 2. How many wireless? 3. What zone number must be used for the Wireless zones? 4. Name some modules compatibles with the Power. Series panels? 5. How is the Keybus wiring?