The COMPASS polarized Target The COMPASS polarized target F. Gautheron On behalf of the

The COMPASS polarized Target The COMPASS polarized target F. Gautheron On behalf of the COMPASS collaboration F. Gautheron / Univ. Bielefeld Spin 2004 10 -16 October 2004 Trieste - 1

The COMPASS polarized Target The goal : To measure the gluon polarization ∆G/G by

The COMPASS polarized Target The goal : To measure the gluon polarization ∆G/G by • the open charm lepto-production channel • high p. T hadron pair events D 0 Accessible from the double spin asymmetry: A exp = N ← ← - N + N ← ← = PB PT f A m. N g qq. X PB Beam polarization PT Target polarization Beam polarization orientation f Dilution factor Target polarization orientation N Number of events F. Gautheron / Univ. Bielefeld Spin 2004 10 -16 October 2004 Trieste - 2

The COMPASS polarized Target The challenge: to run the largest solid polarized target for

The COMPASS polarized Target The challenge: to run the largest solid polarized target for a higher statistic to achieve the highest possible polarization to measure the polarization of the nuclei without harming the experiment to reduce the multiple scattering for efficient reconstruction of D 0 to allow the frequent change of the sign of the polarization to fight against false asymmetries from acceptance changes F. Gautheron / Univ. Bielefeld Spin 2004 10 -16 October 2004 Trieste - 3

The COMPASS polarized Target Choice of the material t-1 - The beam time t

The COMPASS polarized Target Choice of the material t-1 - The beam time t to reach a certain statistical accuracy DA shows the dependency r (f P)2 We define the Figure of Merit (Fo. M) Fo. M = k r (f PT)2 SMC COMPASS Material NH 3 D-butanol 6 Li. D Density 0. 85 1. 10 0. 84 Polarization H: ~0. 90 D: ~0. 50 Packing factor k 0. 60 0. 55 Dilution factor f 0. 176 0. 238 ~0. 50 Fo. M 10. 3 6. 7 16. 0 F. Gautheron / Univ. Bielefeld Spin 2004 10 -16 October 2004 Trieste - 4

The COMPASS polarized Target Magnet PSU + instrument. Dilution refrigerator m 3 He pump

The COMPASS polarized Target Magnet PSU + instrument. Dilution refrigerator m 3 He pump line Magnet NMR system F. Gautheron / Univ. Bielefeld Spin 2004 10 -16 October 2004 Trieste - 5

The COMPASS polarized Target Still pumping line 3 He precooling line Magnet : 2.

The COMPASS polarized Target Still pumping line 3 He precooling line Magnet : 2. 5 T solenoid DB/B < 3. 5 x 10 -5 0. 5 T dipole 3 He/4 He Microwave cavity distiller µ beam Twin target cell 60 cm f=3 cm Total target material : 350 g F. Gautheron / Univ. Bielefeld Mixing chamber : 6 L Temperature: ~60 m. K Spin 2004 10 -16 October 2004 Trieste - 6

The COMPASS polarized Target Material Funnel Granules 6 Li. D Target loading Liquid N

The COMPASS polarized Target Material Funnel Granules 6 Li. D Target loading Liquid N 2 Bath Target cell F. Gautheron / Univ. Bielefeld Spin 2004 10 -16 October 2004 Trieste - 7

The COMPASS polarized Target Microwaves system to polarize (DNP) 0. 2 W for both

The COMPASS polarized Target Microwaves system to polarize (DNP) 0. 2 W for both cells Microwave cavity Microwave stopper Mixing Chamber Freq. counter 2 W due to ~20 m waveguide Power attenuators 2 independent microwave generators 10 W output F. Gautheron / Univ. Bielefeld Frequencies concerned for 6 Li. D at 2. 5 T P>0 [~70. 180 –> 70. 238] GHz P<0 [~70. 285 –> 70. 245] GHz Frequencies continuously adjusted Depends on the degree of polarization + Frequency modulation ± 5 MHz at a rate ~500 Hz to improve speed and degree of polarization Spin 2004 10 -16 October 2004 Trieste - 8

The COMPASS polarized Target NMR system for polarization measurement l/2 coax. 8 NMR coils

The COMPASS polarized Target NMR system for polarization measurement l/2 coax. 8 NMR coils measuring simultaneously 6 Li. D Liverpool Q-meter RF generator Yale card material VME bus Splitter Sweep width: 100 k. Hz, 1000 channels Windows 2000 + Labview Control room Subtracting Q curve + Signal F. Gautheron / Univ. Bielefeld Q curve signal Spin 2004 10 -16 October 2004 Trieste - 9

The COMPASS polarized Target Polarization [%] Typical polarization Build up t 40% (D-but)=5 -6

The COMPASS polarized Target Polarization [%] Typical polarization Build up t 40% (D-but)=5 -6 h Day F. Gautheron / Univ. Bielefeld Spin 2004 10 -16 October 2004 Trieste - 10

The COMPASS polarized Target Magnetic field rotation process Only in frozen spin mode Rotation

The COMPASS polarized Target Magnetic field rotation process Only in frozen spin mode Rotation every 8 hours to cancel systematic error: • time dependant variation • spectrometer acceptance 1 rotation takes 33 minutes B never below 0. 5 T The spin behavior during rotation B up up down up F. Gautheron / Univ. Bielefeld down Spin 2004 10 -16 October 2004 Trieste - 11

The COMPASS polarized Target History of target polarization + pol. (%) - pol. (%)

The COMPASS polarized Target History of target polarization + pol. (%) - pol. (%) 54. 18 - - -47. 40 2002 upstream 55. 49 -52. 72 2002 downstream 56. 89 -47. 47 2003 upstream 56. 81 -50. 67 2003 downstream 54. 07 -48. 95 2004 upstream - preliminary 56. 94 -51. 21 2004 downstream -preliminary 53. 90 -49. 52 2001 upstream 2001 downstream F. Gautheron / Univ. Bielefeld Spin 2004 10 -16 October 2004 Trieste - 12

The COMPASS polarized Target Summary … • Mainly reusing SMC target system • good

The COMPASS polarized Target Summary … • Mainly reusing SMC target system • good figure of merit from 6 Li. D • unique system for magnetic field rotation to reverse polarization • stable operation since 2001 (run ~ 6 month/year) … and outlook • new magnet with a larger acceptance + new microwave cavity • D- butanol with new dopant ? new setup to prepare and study F. Gautheron / Univ. Bielefeld Spin 2004 10 -16 October 2004 Trieste - 13

The COMPASS polarized Target Thank You !!! F. Gautheron / Univ. Bielefeld Spin 2004