The Art of Flow Cytometry Sandra Hope, Ph. D. Microbiology & Molecular Biology Department

The Art of Flow Cytometry Sandra Hope, Ph. D. Microbiology & Molecular Biology Department College of Life Science Brigham Young University

Flow Cytometry • • The Flow cytometer Selecting antibodies Data interpretation Control samples Flow

Flow Cytometry • • The Flow cytometer Selecting antibodies Data interpretation Control samples Flow cytometry applications Variations on a theme Flow cytometry in the RIC

Flow Cytometry

Flow Cytometry

Hydrodynamic Focusing Sample Core Sheath Fluid Flow Cell

Hydrodynamic Focusing Sample Core Sheath Fluid Flow Cell

Hydrodynamic Focusing Flow Cell

Hydrodynamic Focusing Flow Cell

Hydrodynamic Focusing Laser readings

Hydrodynamic Focusing Laser readings

Flow Cytometry Side Scatter Detector LASER (granularity) Forward Scatter Detector (size)

Flow Cytometry Side Scatter Detector LASER (granularity) Forward Scatter Detector (size)

Flow Cytometry Red Fluorescence Detector (protein expression) LASER Specific Antibody with Fluorescent Tag

Flow Cytometry Red Fluorescence Detector (protein expression) LASER Specific Antibody with Fluorescent Tag

Flow Cytometry LASER

Flow Cytometry LASER

Flow Cytometry Green Detector Blue Detector Red Detector Side Scatter Detector (granularity) LASER Forward

Flow Cytometry Green Detector Blue Detector Red Detector Side Scatter Detector (granularity) LASER Forward Scatter Detector (size)

Flow Cytometry Red Detector Green Detector Blue Detector Mirrors Side Scatter Detector (granularity) LASER

Flow Cytometry Red Detector Green Detector Blue Detector Mirrors Side Scatter Detector (granularity) LASER Forward Scatter Detector (size)

Fluorochrome Fluorescence Emission Wavelength Laser light Absorption Wavelength to PMT

Fluorochrome Fluorescence Emission Wavelength Laser light Absorption Wavelength to PMT

Absorption Wavelengths FITC PE APC

Absorption Wavelengths FITC PE APC

Absorption Wavelengths PE APC LASER FITC

Absorption Wavelengths PE APC LASER FITC

Emission Wavelengths FITC PE APC

Emission Wavelengths FITC PE APC

Emission Wavelengths FITC PE APC

Emission Wavelengths FITC PE APC

Flow Cytometry Red Detector Green Detector Blue Detector Mirrors Side Scatter Detector (granularity) LASER

Flow Cytometry Red Detector Green Detector Blue Detector Mirrors Side Scatter Detector (granularity) LASER Forward Scatter Detector (size)

Flow Cytometry Red Detector Green Detector Filters Blue Detector Mirrors Side Scatter Detector (granularity)

Flow Cytometry Red Detector Green Detector Filters Blue Detector Mirrors Side Scatter Detector (granularity) LASER Forward Scatter Detector (size)

Emission Wavelengths FITC PE APC

Emission Wavelengths FITC PE APC

Antibody Selection • Excitation wavelength (laser compatibility) 488 nm, 633 nm • Emission wavelength

Antibody Selection • Excitation wavelength (laser compatibility) 488 nm, 633 nm • Emission wavelength (detector compatibility) Can the RIC flow cytometer detect the color? RIC website, RIC technicians, Dr. Hope • Fluorochrome combinations Choose different colors! RIC website, RIC technicians, Dr. Hope

Antibody Selection http: //ricfacility. byu. edu Equipment Flow. Cytometers Fluorochromes Detectable by the Cytoflex

Antibody Selection http: //ricfacility. byu. edu Equipment Flow. Cytometers Fluorochromes Detectable by the Cytoflex Laser 488 nm - Blue Laser Fluorescent Channel 533/30 488 nm Blue Channel Names/Dyes 638 nm - Red FL 1, FITC, GFP, Alexa-488, SYBR Green, etc. 561 nm - Yellow 585/40 670 Long Pass FL 2, PE, PI, etc. FL 3, Per. CP-Cy 5. 5, PE-Cy 7, m. Cherry, Ds. Red, etc. 405 nm- Violet 640 nm Red 670 Long Pass FL 4, APC, Alexa-647, APC-Cy 7, etc. Fluorescent Channel Names/Dyes 525/40 BL 1, FITC, GFP, Alexa-488, CFSE, Fluo-3, YFP 690/50 BL 2, Per. CP, PI, PC 5. 5, Per. CP-Cy 5. 5 488/8 Blue SSC FSC 780/60 RL 3, APC-H 7, APC-A 750, APC-Cy 7, APCe. Fluor 780 712/25 RL 2, APC-A 700, Alexa-700 660/20 RL 1, APC, Alexa-647, e. Fluor-660 610/20 YL 2, ECD, m. Cherry, PI, PE-Texas Red, PE-CF 594 585/42 YL 1, PE, PI, d. Tomato, Ds. Red 690/50 YL 3, Per. CP, PI, PC 5. 5, Per. CP-Cy 5. 5, PC 5 780/60 YL 4, PC 7, PE-Cy 7 405/10 Violet SSC (nanoparticle) 450/45 VL 1, Pacific Blue, Brilliant Violet 421, CFP, e. Fluor-450, V 450 525/40 VL 2, CFP-YFP, Krome Orange, Am. Cyan, V 500, Brilliant Violet 510 610/20 VL 3, m. Cherry, Brilliant Violet 605, Violet 610, Qdot 605 Other optional Filters Accuri – Student Use Optional Colors 780/60 For Violet laser 660/20 Brilliant Violet 650, Qdot 655 561/10 FSC, SSC for yellow laser Cytoflex – Technician Use

SSC Flow Cytometry Data FSC

SSC Flow Cytometry Data FSC

PE Flow Cytometry Data GFP

PE Flow Cytometry Data GFP

Flow Cytometry Data PE Scatterplots & Histograms GFP

Flow Cytometry Data PE Scatterplots & Histograms GFP

Flow Cytometry Data PE Regions GFP

Flow Cytometry Data PE Regions GFP

Color Gates SSC Flow Cytometry Data FSC GFP

Color Gates SSC Flow Cytometry Data FSC GFP

Flow Cytometry Data SSC Applying a Gate to another graph FSC GFP

Flow Cytometry Data SSC Applying a Gate to another graph FSC GFP

Flow Cytometry Data Interpretation - Identification of populations

Flow Cytometry Data Interpretation - Identification of populations

Flow Cytometry Data Identification of Populations using color gates

Flow Cytometry Data Identification of Populations using color gates

Multicolor Flow Cytometry Identification of Populations using applied gates

Multicolor Flow Cytometry Identification of Populations using applied gates

Multicolor Flow Cytometry T cell Analysis – 6 colors Immunophenotyping Utilizing 6 Color Flow

Multicolor Flow Cytometry T cell Analysis – 6 colors Immunophenotyping Utilizing 6 Color Flow Cytometry 2012, Ward Medical Laboratory, Volume 22, Number 3 http: //www. wardelab. com/22 -3. html

Fluorescence Intensity Settings What does the technician do with your control samples? Negative Control

Fluorescence Intensity Settings What does the technician do with your control samples? Negative Control Sample Cytoflex Cytometer Negative Control Sample with proper voltage settings on the PMT detecting green PMT 223 Counts Filter for Green Fluorescence General light scatter peak should be here 167 R 1 111 55 0 10 General light scatter LASER 0 10 1 10 2 10 3 Green Fluorescence 10 4

Fluorescence Intensity Settings Negative Control Sample Voltage controls sensitivity Cytoflex Cytometer Negative Control Sample

Fluorescence Intensity Settings Negative Control Sample Voltage controls sensitivity Cytoflex Cytometer Negative Control Sample with voltage set too high on PMT for green PMT 223 Counts Filter for Green Fluorescence Sample should peak here 167 R 1 111 55 0 10 General light scatter LASER 0 10 1 10 2 10 3 Green Fluorescence 10 4

Fluorescence Intensity Settings Negative Control Sample Voltage controls sensitivity Cytoflex Cytometer Negative Control Sample

Fluorescence Intensity Settings Negative Control Sample Voltage controls sensitivity Cytoflex Cytometer Negative Control Sample with voltage set extremely high on PMT for green PMT 223 Counts Filter for Green Fluorescence Sample should peak here 167 R 1 111 55 0 10 General light scatter LASER 0 10 1 10 2 10 3 Green Fluorescence 10 4

Fluorescence Intensity Settings Single-Color Control Sample: (check red sample for a red reading) Cytoflex

Fluorescence Intensity Settings Single-Color Control Sample: (check red sample for a red reading) Cytoflex Cytometer Positive Control Sample with proper voltage settings on the PMT detecting red PMT 223 167 Counts Filter for Green Fluorescence Any unstained cells In the sample are measured here R 1 Any cells stained with green-labelled antibody are measured here 111 55 0 10 1 10 2 10 Red Fluorescence LASER 3 10 4

Fluorescence Overlap Single-Color Control Sample: (check red sample for a green reading) Cytoflex Cytometer

Fluorescence Overlap Single-Color Control Sample: (check red sample for a green reading) Cytoflex Cytometer A small amount of red can pass through the green filter PMT Red Control Sample (reading in green should be negative) Some red fluorescence is able to cross through the green filter 223 R 1 Counts Filter for Green Fluorescence 167 111 55 0 10 1 10 2 10 3 Green Fluorescence LASER 10 4

Fluorescence Overlap FITC Spectral Overlap PE APC

Fluorescence Overlap FITC Spectral Overlap PE APC

Compensation Matrix For proper compensation matrix calculations, each experiment needs: • Negative control •

Compensation Matrix For proper compensation matrix calculations, each experiment needs: • Negative control • Single color positive controls = 1 for each color

Fluorescence Overlap Requires Compensation (digital threshold) A small amount of red can pass through

Fluorescence Overlap Requires Compensation (digital threshold) A small amount of red can pass through the green filter PMT Red Control Sample (reading in green should be negative) Some red fluorescence is able to cross through the green filter 223 R 1 Counts Filter for Green Fluorescence 167 111 55 0 10 1 10 2 10 3 Green Fluorescence LASER 10 4

Compensation subtracts false readings A small amount of red can pass through the green

Compensation subtracts false readings A small amount of red can pass through the green filter PMT Red Control Sample (reading in green should be negative) Instrument controls compensate for “fluorescence overlap” of red 223 R 1 Counts Filter for Green Fluorescence 167 111 55 0 10 1 10 2 10 3 Green Fluorescence LASER 10 4

Flow Cytometry Applications Propidium Iodide stains DNA

Flow Cytometry Applications Propidium Iodide stains DNA

Flow Cytometry Applications Cell Cycle Division Apoptosis Nuclear DNA content

Flow Cytometry Applications Cell Cycle Division Apoptosis Nuclear DNA content

Flow Cytometry Applications Cell Death Live = esterase activity) Dead = DNA binding (compromised

Flow Cytometry Applications Cell Death Live = esterase activity) Dead = DNA binding (compromised membranes) Apoptosis = Annexin V Dead = PI

Flow Cytometry Applications Detecting Proteins in Supernatants Negative control Positive control Beads Cytokine panels

Flow Cytometry Applications Detecting Proteins in Supernatants Negative control Positive control Beads Cytokine panels Phosphorylation p. Stat 5 Cytokine Binding p. Stat 3

Variations on a Theme Dark-field Microscopy Camera Amnis Image. Stream Imaging Cytometer

Variations on a Theme Dark-field Microscopy Camera Amnis Image. Stream Imaging Cytometer

Variations on a Theme FACS to PMT’s Laser Charge droplet as it leaves deflection

Variations on a Theme FACS to PMT’s Laser Charge droplet as it leaves deflection plate - + Sort 1 Waste deflection plate Sort 2 Fluorescence – Activated Cell Sorting

FACS Data A B C F D E G

FACS Data A B C F D E G

RIC Flow Cytometry Equipment Cytoflex Flow Cytometer 4 laser, 13 color Technician-run Fall Semester

RIC Flow Cytometry Equipment Cytoflex Flow Cytometer 4 laser, 13 color Technician-run Fall Semester Flow Class Accuri Flow Cytometer 2 laser, 4 color Fixed-voltage Student-run

RIC Facility website http: //ricfacility. byu. edu

RIC Facility website http: //ricfacility. byu. edu

RIC Facility Scheduler

RIC Facility Scheduler

RIC Facility Scheduler http: //ricfacility. byu. edu

RIC Facility Scheduler http: //ricfacility. byu. edu

The Art of Flow Cytometry

The Art of Flow Cytometry