The application of GEANT 4 simulation code for brachytherapy treatment Maria Grazia Pia INFN

The application of GEANT 4 simulation code for brachytherapy treatment Maria Grazia Pia INFN Genova, Italy and CERN/IT Maria. Grazia. Pia@cern. ch F. Foppiano 1, S. Agostinelli 1, 2, S. Garelli 1, G. Paoli 1, P. Nieminen 3 1 National Cancer Institute and 2 Physics Dept. of Genova, 3 European Space Agency IXth International Conference on Calorimetry in High Energy Physics Annecy, 10 October 2000 M. G. Pia et al. 1

Outline /Introduction to brachytherapy /Application of Monte Carlo simulation to brachytherapy /The GEANT 4

Outline /Introduction to brachytherapy /Application of Monte Carlo simulation to brachytherapy /The GEANT 4 toolkit and its extension targeted to medical physics /Results /Simulation of the attenuation coefficients for various materials /Simulation of a brachytherapy radioactive source /Description of 192 Ir source geometry used in real treatments /Simulation of the anisotropy function in water /Simulation of isodoses in water /Conclusions and future goals M. G. Pia et al. 2

What is brachytherapy? ] Brachytherapy is a medical therapy used for cancer treatments ]

What is brachytherapy? ] Brachytherapy is a medical therapy used for cancer treatments ] Radioactive sources are used to deposit therapeutic doses near tumors while preserving surrounding healthy tissues ] In HDR endocavitary brachytherapy: • a radioactive source, for example 192 Ir, is used • the source moves along catheters inserted in natural cavities of the body, e. g. vagina or bronchi; this allows the deposition of therapeutic tumor dose right where it is needed • the source track is programmed by an after-loading unit M. G. Pia et al. 3

Brachytherapy treatment set-up A naso-pharynx endocavitary treatment After-loading unit Catheter along which source moves

Brachytherapy treatment set-up A naso-pharynx endocavitary treatment After-loading unit Catheter along which source moves M. G. Pia et al. 4

Brachytherapy treatment planning (1) A typical vaginal treatment plan: source moves along a single

Brachytherapy treatment planning (1) A typical vaginal treatment plan: source moves along a single catheter M. G. Pia et al. 5

Brachytherapy treatment planning (2) A typical intra-uterine treatment plan: source moves along 3 catheters

Brachytherapy treatment planning (2) A typical intra-uterine treatment plan: source moves along 3 catheters M. G. Pia et al. 6

Monte Carlo for brachytherapy Monte Carlo simulation topics for brachytherapy: o Dose calculation n

Monte Carlo for brachytherapy Monte Carlo simulation topics for brachytherapy: o Dose calculation n Computation of dose deposition kernels for treatment planning dose calculation algorithms based on convolution/superposition methods n Separation of primary, first scatter and multiple scatter components for complex dose deposition models /Computation of other model-dependent parameters, e. g. anisotropy function /Accurate computation of dose deposition in high gradient regions (i. e. near sources) o Verification of experimental calibration procedures M. G. Pia et al. 7

GEANT 4 is an Object Oriented Toolkit for the simulation of the passage of

GEANT 4 is an Object Oriented Toolkit for the simulation of the passage of particles through matter The transparency of physics Extensibility to satisfy new user requirements thanks to the OO technology Subject to independent validation by a large user community worldwide Advanced functionalities in geometry, physics, visualisation etc. Geant 4 provides various features relevant for medical applications Adopts standards wherever available (de jure or de facto) M. G. Pia et al. Quality Assurance based on sound software engineering Use of evaluated data libraries User support organization by a large international Collaboration of experts 8

GEANT 4 Low Energy Electromagnetic Physics Geant 4 Low Energy Electromagnetic package extends the

GEANT 4 Low Energy Electromagnetic Physics Geant 4 Low Energy Electromagnetic package extends the coverage of physics interactions down to 250 e. V for electrons and photons • based on the LLNL data libraries • shell effects down to ~ 1 ke. V for hadrons and ions • Bethe-Block above 2 Me. V • Ziegler and ICRU parameterisations (with material dependence) • free electron gas model • quantal harmonic oscillator model • charge dependence (Barkas effect) Further extensions are in progress Relevant for medical, space science, astrophysics etc. applications M. G. Pia et al. 9

Simulation of Simulated water (attentuation coefficient) versus NIST data with Geant 4 Standard electromagnetic

Simulation of Simulated water (attentuation coefficient) versus NIST data with Geant 4 Standard electromagnetic package and Low Energy extension M. G. Pia et al. 10

Description of -Selectron 192 Ir source ] GEANT 4 allows complete flexible description of

Description of -Selectron 192 Ir source ] GEANT 4 allows complete flexible description of the real geometry ] 192 Ir l l energy spectrum currently described as monochromatic at 356 ke. V will soon be described by the new GEANT 4 Radioactive. Decay class M. G. Pia et al. 11

Simulation of dose deposition in water ] The simulated source is placed in a

Simulation of dose deposition in water ] The simulated source is placed in a 30 cm water box ] The dose deposition is investigated in the longitudinal plane ] Plane is partitioned in 1 million 1 mm 3 voxels ] A minimum of 10 millions photons are generated on the 4 solid angle -Selectron 192 Ir source M. G. Pia et al. Longitudinal plane partitioned in cells 12

Investigated quantities: anisotropy ] The dose deposition is not isotropic due to source geometry

Investigated quantities: anisotropy ] The dose deposition is not isotropic due to source geometry and autoabsorption, encapsulation and shielding effects ] Anisotropy can be described by a simple angular function which can be computed by re-sampling our simulated voxels grid calculations M. G. Pia et al. 13

Investigated quantities: isodoses ] The simulated dose deposition data can also be used to

Investigated quantities: isodoses ] The simulated dose deposition data can also be used to derive isodoses M. G. Pia et al. 14

Conclusions and future goals ] Monte Carlo simulation is useful in brachytherapy both to

Conclusions and future goals ] Monte Carlo simulation is useful in brachytherapy both to obtain model-dependent parameters and to verify experimental data ] GEANT 4 offers reliable particle-matter Monte Carlo simulation in a flexible modern object-oriented toolkit ] We have used GEANT 4 to simulate coefficients and a commercial brachytherapy source with full dose deposition /More realistic description of 192 Ir source energy spectrum with the new GEANT 4 Radioactive. Decay class /Simulation of shielded brachytherapy applicators M. G. Pia et al. 15