Test Setup – Notes • Input Amplitude: 8 VPP • Input Frequency: 10 Hz,

Test Setup – Notes • Input Amplitude: 8 VPP • Input Frequency: 10 Hz, 40 Hz, 100 Hz • Input Source: Audio Precision, Unbalanced GND output • Samples Collected: 4, 096 • Expected Output: 8 VPP * [102. 88 / (102. 88 + 100 k)] = 8. 22 m. VPP • Hardware: ADS 1298 RECGFE-PDK TI Confidential – NDA Restrictions 2

Test Setup – Register Settings TI Confidential – NDA Restrictions 3

Test Setup – Register Settings TI Confidential – NDA Restrictions 3

S 2 closed, 10 Hz, 8. 23 m. VPP TI Confidential – NDA Restrictions

S 2 closed, 10 Hz, 8. 23 m. VPP TI Confidential – NDA Restrictions 4

S 2 closed, 10 Hz, -39. 75 d. B TI Confidential – NDA Restrictions

S 2 closed, 10 Hz, -39. 75 d. B TI Confidential – NDA Restrictions 5

S 2 closed, 40 Hz, 8. 16 m. VPP TI Confidential – NDA Restrictions

S 2 closed, 40 Hz, 8. 16 m. VPP TI Confidential – NDA Restrictions 6

S 2 closed, 40 Hz, -39. 83 d. B TI Confidential – NDA Restrictions

S 2 closed, 40 Hz, -39. 83 d. B TI Confidential – NDA Restrictions 7

S 2 closed, 100 Hz, 7. 83 m. VPP TI Confidential – NDA Restrictions

S 2 closed, 100 Hz, 7. 83 m. VPP TI Confidential – NDA Restrictions 8

S 2 closed, 100 Hz, -40. 19 d. B TI Confidential – NDA Restrictions

S 2 closed, 100 Hz, -40. 19 d. B TI Confidential – NDA Restrictions 9

S 2 open, 10 Hz, 8. 22 m. VPP TI Confidential – NDA Restrictions

S 2 open, 10 Hz, 8. 22 m. VPP TI Confidential – NDA Restrictions 10

S 2 open, 10 Hz, -39. 76 d. B TI Confidential – NDA Restrictions

S 2 open, 10 Hz, -39. 76 d. B TI Confidential – NDA Restrictions 11

S 2 open, 40 Hz, 8. 45 m. VPP TI Confidential – NDA Restrictions

S 2 open, 40 Hz, 8. 45 m. VPP TI Confidential – NDA Restrictions 12

S 2 open, 40 Hz, -39. 52 d. B TI Confidential – NDA Restrictions

S 2 open, 40 Hz, -39. 52 d. B TI Confidential – NDA Restrictions 13

S 2 open, 100 Hz, 9. 17 m. VPP TI Confidential – NDA Restrictions

S 2 open, 100 Hz, 9. 17 m. VPP TI Confidential – NDA Restrictions 14

S 2 open, 100 Hz, -38. 81 d. B TI Confidential – NDA Restrictions

S 2 open, 100 Hz, -38. 81 d. B TI Confidential – NDA Restrictions 15