System Design Network Set Up DCN Next Gen

  • Slides: 6
Download presentation
System Design Network Set Up DCN Next Gen CCU Cat 5 Cobranet Interface è

System Design Network Set Up DCN Next Gen CCU Cat 5 Cobranet Interface è Direct Connection Cross Cable Full duplex Transmit and receive at the same time No Collisions Security Systems 1 Cobranet Interface ST/PRM 3 -EU | 06. Oct. 05 DCNNG CN SD DCN Next Gen | © Robert Bosch Gmb. H reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

CROSS Cable TX+ 1 TX- 2 3 RX+ 6 RX- RX+ 3 RX- 6

CROSS Cable TX+ 1 TX- 2 3 RX+ 6 RX- RX+ 3 RX- 6 n/a 4 n/a 5 n/a 7 n/a 8 1 TX+ 2 TX 4 n/a 5 n/a 7 n/a 8 n/a * Note: Even though pins 4, 5, 7 and 8 are not used, it is mandatory that they be present in the cable. Security Systems 2 ST/PRM 3 -EU | 06. Oct. 05 DCNNG CN SD | © Robert Bosch Gmb. H reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

System Design DCN Next Gen CCU Cobranet Interfaces è Hub Transmits data to all

System Design DCN Next Gen CCU Cobranet Interfaces è Hub Transmits data to all ports Half duplex Cannot transmit and receive at the same time Collision transmission stops Security Systems 3 ST/PRM 3 -EU | 06. Oct. 05 DCNNG CN SD | © Robert Bosch Gmb. H reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Cobranet Interfaces

System Design Network Set Up DCN Next Gen CCU Cobranet Interfaces è Switch Straight

System Design Network Set Up DCN Next Gen CCU Cobranet Interfaces è Switch Straight Cable Can route data from one port to an other port Multiple paths possible Remembers the communication path Security Systems 4 Switch ST/PRM 3 -EU | 06. Oct. 05 DCNNG CN SD DCN Next Gen | © Robert Bosch Gmb. H reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Cobranet Interfaces

Straight Thru Cable TX+ 1 TX- 2 1 TX+ 2 TX- RX+ 3 RX-

Straight Thru Cable TX+ 1 TX- 2 1 TX+ 2 TX- RX+ 3 RX- 6 n/a 4 n/a 5 n/a 7 n/a 8 3 RX+ 6 RX 4 n/a 5 n/a 7 n/a 8 n/a * Note: Even though pins 4, 5, 7 and 8 are not used, it is mandatory that they be present in the cable. Security Systems 5 ST/PRM 3 -EU | 06. Oct. 05 DCNNG CN SD | © Robert Bosch Gmb. H reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.

System Design End of Section Security Systems 6 ST/PRM 3 -EU | 06. Oct.

System Design End of Section Security Systems 6 ST/PRM 3 -EU | 06. Oct. 05 DCNNG CN SD Cobra. Net Menu | © Robert Bosch Gmb. H reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties.