Surveying Level Loop Civil Engineering and Architecture 2010
- Slides: 17
Surveying Level Loop Civil Engineering and Architecture © 2010 Project Lead The Way, Inc.
Level Loop (or Closed Circuit) Instrument location (TYP) FS 4. 26 ft t S= f 3 7. 1 1 B Elev. 100. 00 ft Turning Point (TYP)
Closed Circuit or Level Loop AUTO LEVEL READINGS STADIA PT (+) BS BM 7. 13 TP-1 HI (-) FS ELEV 107. 13 X 100. 00 4. 26 102. 87 TOP/BOT STADIA DIST /Angle �
Level Loop (or Closed Circuit) = S B Elev. 100. 00 ft 5 1. 7 ft FS = 2. 99 f t 2 Turning Point Elev. 102. 87
Closed Circuit or Level Loop AUTO LEVEL READINGS STADIA PT (+) BS BM TP-1 TBM HI (-) FS ELEV 7. 13 107. 13 X 100. 00 1. 75 104. 62 4. 26 102. 87 2. 99 101. 63 TOP/BOT STADIA DIST /Angle �
Level Loop (or Closed Circuit) BS = 5. 62 ft Elev. 101. 63 ft 5 FS = 4 =6 . 12 ft BS = 0. 94 ft 8 ft 9. 7 FS . 34 =3 BS = 9 . 01 FS ft Elev. 100. 00 ft
Closed Circuit or Level Loop AUTO LEVEL READINGS STADIA PT (+) BS HI (-) FS ELEV BM 7. 13 107. 13 X 100. 00 TP-1 1. 75 104. 62 4. 26 102. 87 TBM 5. 62 107. 25 2. 99 101. 63 TP-2 0. 94 102. 18 6. 01 101. 24 TP-3 9. 12 103. 32 7. 98 94. 20 3. 34 99. 98 POR TOP/BOT STADIA DIST /Angle �
Closure Error The difference between a measured or calculated elevation and the true or established elevation. Closure Error = Final Elev. – Initial Elev.
Closed Circuit or Level Loop AUTO LEVEL READINGS STADIA PT (+) BS HI (-) FS ELEV BM 7. 13 107. 13 X 100. 00 TP-1 1. 75 104. 62 4. 26 102. 87 TBM 5. 62 107. 25 2. 99 101. 63 TP-2 0. 94 102. 18 6. 01 101. 24 TP-3 9. 12 103. 32 7. 98 94. 20 POR 3. 34 99. 98 - 100. 00 CLOSURE ERROR = - 0. 02 ft TOP/BOT STADIA DIST /Angle �
Allowable Error • The allowable error depends on the type and purpose of the surveying. • In this class, we will use
Closed Circuit or Level Loop AUTO LEVEL READINGS STADIA PT (+) BS HI (-) FS BM 7. 13 107. 13 X TP-1 1. 75 104. 62 4. 26 TBM 5. 62 107. 25 2. 99 TP-2 0. 94 102. 18 6. 01 TP-3 9. 12 103. 32 7. 98 POR 3. 34 ELEV TOP/BOT STADIA 100. 00 BS 8. 63 / 5. 63 102. 87 FS 5. 69 / 2. 83 BS 3. 15 / 0. 25 101. 63 FS 4. 44 / 1. 54 BS 6. 67 /4. 57 101. 24 FS 7. 08 / 4. 94 BS 1. 84 / 0. 04 94. 20 FS 8. 94 / 7. 02 BS 10. 42 / 7. 82 DIST /Angle 300 ft 286 ft 290 ft 210 ft 214 ft 180 ft 192 ft 260 ft 248 ft 99. 98 FS 4. 58 / 2. 10 - 100. 00 TOTAL = 2470 ft CLOSURE ERROR = - 0. 02 ft
Level Loop (or Closed Circuit) Instrument location (TYP) 0 29 3 f 00 290 ft 210 ft 286 ft ft t 3 8 24 ft 5 19 2 ft 180 ft 4 21 4 ft Elev. 100. 00 ft 260 ft Elev. 101. 63 ft
Allowable Error Survey data is acceptable
Reducing Errors • Check that bubble is centered for EVERY rod reading. • Keep the rod plumb during each reading. • Establish equal BS and FS reading distances. – Equal reading distances will cancel out any error caused by the line of sight not being parallel with the axis of the bubble tube. – This is not always possible due to terrain.
Common Errors • • Faulty rod reading (verify reading) Rod not fully extended (high reading) Tripod movement during reading Confusion between recording BS and FS entries in the field book
Can You Top That? Courtesy NOAA Photo Library http: //www. photolib. noaa. gov/htmls/theb 1809. htm According to NOAA, this survey party made 329 setups in 7 hours and 55 minutes working in an area of extreme grades in the Western United States in 1934.
Image Sources National Oceanographic and Atmospheric Administration Photo Library http: //www. photolib. noaa. gov/cgs/marks 1. html
- Lv loop
- Civil rights and civil liberties webquest
- Classification of surveying
- Diagram blok oven listrik
- Fifth gear loop the loop
- Open loop vs closed loop in cars
- Manakah yang lebih baik open loop atau close loop system
- Pernyataan do while
- Accidental whorl
- Multi loop pid controller regolatore pid multi loop
- Kambiz farahmand
- Unsw 8621
- Hse in civil engineering
- Civil engineering completed risks
- Tam grouting
- What is formwork in civil engineering
- Introduction to civil engineering
- Role of civil engineering