Agenda ● Overview ● Detailed presentation ● Features ● Security ● Protocols ● Products

Agenda ● Overview ● Detailed presentation ● Features ● Security ● Protocols ● Products supported ● Demonstration ● Summary Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 2

Power. SCADA Expert solution ● A fully integrated, reliable, flexible, secured and high performance

Power. SCADA Expert solution ● A fully integrated, reliable, flexible, secured and high performance real-time power monitoring and control solution ● Designed to monitor and control electrical distribution where electrical energy availability and reliability is critical: ● HV / MV / LV / MCC ● Large sites with safety requirements ● Continuous or sensitive processes Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 3

Power. SCADA Expert solution ● Custom-engineered to fit user needs ● Designed as an

Power. SCADA Expert solution ● Custom-engineered to fit user needs ● Designed as an operatordedicated system ● Large protocol support Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 4

Power. SCADA Expert solution ● Improves power reliability and operation efficiency ● Controls up

Power. SCADA Expert solution ● Improves power reliability and operation efficiency ● Controls up to +2000 devices, +200 k tags ● High performance ● 1 s response time and Sequence Of Event recording ● Alarming ● 1 ms resolution ● Data and waveform collection for adequate actions ● Outstanding reliability via redundant and modular architecture Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 5

Modular and Scalable by design ● Server Modules ● IO Server: Collects device data

Modular and Scalable by design ● Server Modules ● IO Server: Collects device data and alarms, handles the control commands ● File Server: Stores the data collected ● Alarm server: Processes alarms and presents them to the client interface ● Trend server: Computes and provides trends ● Report server: prepares some data for display. It is not a full reporting tool ● Web server: Provides the web pages for the web clients ● Fat Clients (running the client application) ● Control Client: Allows to view and control the Power. Logic application ● View only client: Allows to view only the application ● Web clients (connecting to the Web server) ● Web control client: Allows to view and control the Power. Logic application ● Web View only client: Allows to view only the application th Schneider Electric - Power BU – Denis Arnaud – September 15 2011 High performance: Ø Controls up > 2000 devices, > 200 k tags Ø Can support 1 s response time Ø Sequence Of Event recording & alarming with 1 ms resolution. With external hardware for timing 6

User Interface ● Customizable ● To align with other tools, reduce training. ● To

User Interface ● Customizable ● To align with other tools, reduce training. ● To simplify navigation via tab browsing ● Devices combination ● Alarming ● Alarm banner ● Line & device status indicator ● Click for easy data access ● Click to drill through sub-sections ● Displays selected data ● Display waveforms and trends ● Controls ● Authentication for security ● Export/import ● Faster roll out for multiple sites and/or devices ● capacity to replicate a set up, or the interface Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 7

Controls ● Real time ● Any command is immediately sent ● Status changes reported

Controls ● Real time ● Any command is immediately sent ● Status changes reported graphically ● Failure to execute results in an alarm ● Security ● Based on user’s privileges ● Depends on the device and potential controls ● Control logging for auditing purposes ● Pop-up confirmation to ensure safety ● Increased security using Windows Security Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 8

Device customization ● Composite devices ● Creates a graphical representation of several devices ●

Device customization ● Composite devices ● Creates a graphical representation of several devices ● Allows the “combined device” to act as a single device ● Device concentration ● Combines device data points to provide a meaningful business related measurement point ● Export/Import ● Allows to re-use customized devices Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 9

Security ● Windows Security ● Microsoft Active Directory capable ● Uses company policies ●Password

Security ● Windows Security ● Microsoft Active Directory capable ● Uses company policies ●Password renewals ●De-activating an account ● Multi level Security ● Console access ● Device level ● NERC document ● To help ensure NERC compliant solution Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 10

Protocols supported ● Native device protocol support ● IEC 61850 Edition 1 (New) ●

Protocols supported ● Native device protocol support ● IEC 61850 Edition 1 (New) ● DNP 3 ● Mod. Bus TCP/IP ● RS-485 Modbus via Gateway ● SNMP ● Optional support ● IEC 80750 -5 -104 as a client ● Data Access (Other protocols support) ● OPC DA Version 1 & 2 Client Server ● ODBC Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 11

Why IEC 61850? What is it? ● IEC 61850: ● Design standard for electrical

Why IEC 61850? What is it? ● IEC 61850: ● Design standard for electrical substation automation ● Single protocol, high interoperability, fast data transfer ● Impact on installations ● Multiple vendors can be supported through 1 protocol (device interoperation) ● Normalized mapping and naming to facilitate integration of new devices and evolution of the site ● Cost effective ● Please refer to IEC 61850 documentation Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 12

Devices supported ● Schneider Electric (Embedded support) ● Protective relays ●Micrologic 5. 0 P

Devices supported ● Schneider Electric (Embedded support) ● Protective relays ●Micrologic 5. 0 P and 6. 0 P, A & A fw 2, H ●SEPAM Series 20, 40, 80 & 2000 (s 36) ● Branch Circuit/Power Monitors ●BCPM/BCM 42 ●CM 4 Series ●PM 7 & PM 8 Series ●ION 7650 ● PLCs ●Quantum (only one to pass time and date stamp) ●Momentum ●Premium ●M 340 ● Motor Management System ●Tesys T ● Easy integrations of 3 rd party Mod. Bus devices for real-time support Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 13

Operating Systems supported ● Server ● Windows 2003 Server SP 2(32 bit) ● Windows

Operating Systems supported ● Server ● Windows 2003 Server SP 2(32 bit) ● Windows XP Professional SP 3 (32 bit) ● Windows Server Standard Edition 2008 SP 2 (32 and 64 bit) ● Windows Server 2008 R 2 SP 1 had not been fully tested and is not recommended. On-going CE project may change this ● Network Communications ● Self-healing rings and multiple-ring support ● Ethernet TCP/IP ● Network Time Protocol (NTP time synchronization) ● Client ● Windows Vista Business SP 2 (32 AND 64 bit) ● Windows 7 (32 and 64 bit) Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 14

Demonstration of a project Schneider Electric - Power BU – Denis Arnaud – September

Demonstration of a project Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 15

Key Points to Remember ● Power. SCADA Expert is a Power SCADA ● Support

Key Points to Remember ● Power. SCADA Expert is a Power SCADA ● Support drivers and protocols for power control and monitoring ● Supports IEC 61850 natively ● Power. SCADA Expert ● Is a proven solution ● Is Custom engineered to fit your needs ● Can be expanded, modified to adapt to your needs and site changes ● Power. SCADA Expert is þSecure þModular þScalable þReliable Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 16

Make the most of your energy Schneider Electric - Power BU – Denis Arnaud

Make the most of your energy Schneider Electric - Power BU – Denis Arnaud – September 15 th 2011 17