Store Summary Store Avg Init. Lumi (E 30) Avg Deliv’d Lumi (nb-1) Time (hr)

Store Summary Store Avg Init. Lumi (E 30) Avg Deliv’d Lumi (nb-1) Time (hr) How did it end? 7286 280. 8 7616 17. 2 Normal 7289 272. 5 7138 15. 7 Normal 7290 273. 2 7022 15. 0 Normal 7291 250. 2 7012 17. 0 Normal 7292 277. 9 6262 12. 4 Normal 7293 279. 9 8100 17. 7 Normal TEL trips, pbar long blowup 7294 251. 5 8026 23. 0 Normal TEL trips 7295 255. 0 7041 15. 9 Normal TEL trips 7296 274. 6 3534 5. 3 Quench 7306 123. 6 Tevatron Coordinator - FNAL Comments CDF lumi readback problems Small stash 12/12/2021

The Numbers Avg Initial Lumi [E 30] Lumi Life time [hr] PNG [E 9]

The Numbers Avg Initial Lumi [E 30] Lumi Life time [hr] PNG [E 9] PNG Life Time [hr] ANG [E 9] Prot Eff Prot Pbar Life. ANG Emit. Eff Emit RMS Length time Life from Life Bunch Life @ 150 Time Lumi Time Length time on [hr] [pi mm [hr] [ns] [hr] Helix mrad] [hr] Prot Pbar Ineff Pbar Life. Prot Pbar @ Ineff time Ineff 150 @ @ Ramp on 150 [%] Helix [%] [hr] [%] Prot Pbar Store Ineff Length Sqz [hr] [%] How ended? Avg Deliv'd Lumi [nb-1] Store Date 7306 10/30/09 0: 38 126. 6 6. 4 10518 66. 3 1264 18. 6 13. 6 11. 4 1. 68 -26. 8 1. 51 -36. 8 19. 2 27. 8 2. 4 -0. 4 1. 9 2. 8 0. 0 0. 7 3. 0 Not Completed 1061 7296 10/29/09 3: 04 274. 6 6. 3 9809 47. 2 2920 19. 1 14. 5 11. 64 -17. 0 1. 81 -33. 9 8. 9 13. 1 4. 5 0. 9 2. 0 4. 1 1. 1 -0. 1 5. 3 Tev. Quench 3534 7295 10/28/09 8: 26 255. 0 6. 7 9323 34. 0 2918 21. 4 14. 3 13. 5 1. 70 -23. 9 1. 90 -35. 4 9. 9 20. 7 4. 4 0. 6 2. 2 4. 0 1. 2 0. 3 15. 9 Normal 7041 7294 10/27/09 7: 37 251. 5 6. 2 9187 45. 8 2977 20. 3 13. 7 11. 1 1. 65 -24. 8 1. 62 -24. 7 5. 4 23. 0 6. 7 1. 0 1. 7 3. 9 1. 0 0. 2 23. 0 Normal 8026 7293 10/26/09 11: 25 279. 9 6. 5 9581 46. 6 2916 22. 4 13. 7 11. 2 1. 69 -27. 2 1. 65 -27. 5 7. 0 18. 8 5. 7 0. 8 2. 1 4. 0 1. 2 0. 3 17. 7 Normal 8100 7292 10/25/09 21: 28 277. 9 6. 2 9445 34. 7 2960 19. 8 13. 5 12. 1 1. 66 -22. 2 1. 68 -25. 1 6. 8 21. 5 5. 9 1. 1 2. 1 4. 0 1. 0 0. 0 12. 4 Normal 6262 7291 10/25/09 1: 41 250. 2 6. 4 8975 40. 5 2805 20. 1 13. 3 12. 2 1. 70 -28. 7 1. 69 -27. 1 6. 5 28. 8 5. 9 1. 1 2. 0 4. 4 1. 0 0. 2 17. 0 Normal 7012 7290 10/24/09 8: 30 273. 2 6. 2 9185 44. 6 2959 20. 0 13. 5 11. 1 1. 62 -25. 9 1. 58 -22. 2 5. 9 20. 0 6. 3 1. 0 1. 9 4. 0 0. 9 0. 4 15. 0 Normal 7022 7289 10/23/09 14: 51 272. 5 6. 1 9816 46. 2 2781 20. 0 13. 4 10. 9 1. 68 -29. 1 1. 54 -21. 8 10. 9 18. 1 3. 7 0. 9 2. 1 3. 8 1. 0 0. 3 15. 7 Normal 7138 7286 10/22/09 13: 20 280. 8 6. 0 9510 49. 7 2911 19. 0 13. 3 10. 6 1. 63 -25. 6 1. 56 -21. 9 7. 3 24. 6 5. 2 1. 1 2. 1 4. 6 1. 1 0. 4 17. 2 Normal 7616 7285 10/21/09 20: 45 271. 2 6. 4 9462 40. 3 2924 20. 1 13. 8 12. 1 1. 60 -27. 0 1. 55 -24. 6 6. 8 18. 0 5. 8 1. 0 2. 4 4. 2 1. 4 0. 4 14. 7 Normal 6925 7284 10/21/09 2: 07 249. 8 6. 9 8786 35. 4 2955 20. 4 12. 3 14. 9 2. 08 -47. 2 1. 68 -26. 8 6. 7 23. 0 5. 4 1. 3 2. 6 4. 7 2. 8 0. 1 16. 4 Normal 7041 7283 10/20/09 6: 47 269. 3 6. 5 9385 43. 4 2858 20. 3 13. 4 12. 1 1. 64 -26. 9 1. 53 -28. 7 4. 6 15. 3 8. 1 1. 1 2. 3 4. 4 1. 5 0. 4 16. 9 Normal 7233 7282 10/19/09 12: 54 172. 7 6. 8 9775 36. 8 1806 20. 4 12. 1 14. 3 2. 29 -72. 3 1. 42 -23. 6 10. 6 29. 0 3. 1 -0. 7 2. 0 2. 5 0. 7 0. 1 16. 2 Normal 4847 7277 10/18/09 8: 56 270. 8 6. 3 9318 50. 5 2859 19. 0 13. 4 11. 4 1. 62 -25. 7 1. 54 -20. 7 6. 4 17. 5 6. 0 1. 1 2. 1 3. 7 1. 8 0. 2 16. 0 Normal 7106 7276 10/17/09 15: 06 267. 4 6. 1 8830 43. 4 2925 19. 8 13. 0 11. 1 1. 64 -28. 1 1. 54 -20. 8 7. 2 21. 7 5. 8 0. 8 1. 9 3. 9 2. 5 0. 2 16. 2 Normal 7109 7275 10/16/09 20: 39 236. 2 6. 8 9353 41. 4 2732 19. 3 12. 3 14. 2 2. 23 -65. 9 1. 52 -22. 4 11. 9 12. 4 3. 4 1. 0 1. 9 4. 5 2. 2 0. 4 16. 6 Normal 6588 7270 10/16/09 1: 20 264. 3 6. 4 9715 26. 7 2846 21. 1 14. 2 14. 1 1. 65 -28. 6 1. 58 -23. 1 6. 5 14. 9 6. 0 1. 1 2. 2 4. 1 1. 5 0. 4 4. 9 Tev. Quench 3261 7269 10/15/09 4: 22 228. 4 5. 8 9833 32. 6 2234 19. 4 12. 9 11. 1 1. 66 -18. 9 1. 49 -20. 8 12. 4 17. 4 3. 2 0. 1 2. 0 3. 8 1. 3 0. 2 19. 3 Normal 6617 7265 10/14/09 6: 47 237. 8 6. 6 9562 42. 0 2417 19. 1 12. 9 13. 3 1. 64 -26. 2 1. 52 -25. 1 5. 8 19. 9 6. 3 0. 2 1. 8 3. 7 1. 6 -0. 4 16. 1 Normal 6434 7264 10/13/09 18: 04 280. 5 5. 2 9510 47. 0 2946 20. 4 13. 4 8. 2 1. 67 -26. 3 1. 67 -30. 8 11. 3 26. 5 3. 8 0. 6 2. 1 4. 9 2. 0 0. 1 10. 8 Normal 5626 7261 10/12/09 20: 49 257. 7 6. 2 9217 26. 9 2716 19. 3 13. 2 13. 8 1. 64 -26. 6 1. 61 -23. 8 9. 6 16. 5 4. 2 0. 8 1. 9 4. 4 1. 9 -0. 2 15. 7 Normal 6498

The lumi chart Initial Luminosity vs (Proton Intensity * Pbar Intensity) 400 Average Initial

The lumi chart Initial Luminosity vs (Proton Intensity * Pbar Intensity) 400 Average Initial Luminosity [1030 cm-2 s-1] 350 300 Last 200 Stores Last 10 Stores 250 Last Store 200 150 100 50 0 0 5 Tevatron Coordinator - FNAL 10 15 20 25 # Prot [109] * # Pbar [109] / [106] 12/12/2021 30 35 3

Problems • • Pbar long blowup at the beginning of stores RF pond water

Problems • • Pbar long blowup at the beginning of stores RF pond water pressure – cleaned strainers CDF lumi readback problems TEL trips (swapped IP power supply) A 2 lead flow - orifice changed A 4 quench (St# 7296) due to cryo control power E 4 Quanch @160 Ge. V, not understood (adjusted chroms) Tevatron Coordinator - FNAL 12/12/2021 4

Studies/Work Completed • • Tune, coupling & chromaticity adjustments for ramp and squeeze Separator

Studies/Work Completed • • Tune, coupling & chromaticity adjustments for ramp and squeeze Separator scans (+1% Lumi at CDF) D 0 IP moved, orbit stab corrector change reverted Direct chromaticity measurements on ramp & squeeze Tevatron Coordinator - FNAL 12/12/2021 5

D 0 IP Tevatron Coordinator - FNAL 12/12/2021 6

D 0 IP Tevatron Coordinator - FNAL 12/12/2021 6

Ghost line quench? Tevatron Coordinator - FNAL 12/12/2021 7

Ghost line quench? Tevatron Coordinator - FNAL 12/12/2021 7

IPM work • Changed to new HV ON routine with better diagnostics • By

IPM work • Changed to new HV ON routine with better diagnostics • By code archeology, found that measurements which failed HV test were not properly discarded – Fixed, but it seems this was not the cause of the fluctuating signal • Added automatic front-end hard reset if persistent front-end error detected • Added hard abort after 10 consecutive HV timeouts – To save MCP, and avoid constant HV ON cases. – Caused issue with proton injection, fixed temporarily with special “injection wait” SPEC • Timing scan (see pic) – Seems bad timing may be the cause of the correlation between detected signal strength and sigma • Found one board off by one sample, causes cut profiles. – To be addressed Tevatron Coordinator - FNAL 12/12/2021 8

IPM timing scan Tevatron Coordinator - FNAL 12/12/2021 9

IPM timing scan Tevatron Coordinator - FNAL 12/12/2021 9

Board sync issue Related to new timing delay value? Race condition? Tevatron Coordinator -

Board sync issue Related to new timing delay value? Race condition? Tevatron Coordinator - FNAL 12/12/2021 10

Studies • Redo IPM EOS with better vacuum datalogging (15 mins) • T 980

Studies • Redo IPM EOS with better vacuum datalogging (15 mins) • T 980 (2 h, daytime) • Tune Mult (2 h) • B 48 separator flourinert re-fill (between stores) Tevatron Coordinator - FNAL 12/12/2021 11