Store Summary Avg Init Lumi E 30 Avg

  • Slides: 9
Download presentation
Store Summary Avg Init. Lumi (E 30) Avg Deliv’d Lumi (nb-1) Time (hr) How

Store Summary Avg Init. Lumi (E 30) Avg Deliv’d Lumi (nb-1) Time (hr) How did it end? Comments 7530 289. 1 14. 5 6354 Normal D 17 sep spark @lbseq 22 7533 257. 8 18. 7 7179 Normal 7534 234. 5 16. 4 6166 Normal 7535 204. 4 15. 9 5212 Normal 7536 243. 9 25. 5 5505 Normal 7559 226. 4 3. 5 2060 Quench B 11 sep spark 7562 257. 6 6. 5 3811 Quench B 11 sep spark 7573 238. 5 10. 7 4773 Abort TRF 8 trip + TRF 2 trip = store lost 7576 263. 3 12. 5 5855 Normal 7577 273. 0 5. 3 3362 Abort 7580 264. 1 Store bad cable T: SF Normal 7581 Tevatron Coordinator - FNAL 12/17/2021

The Numbers Store Date Avg Initial Lumi [E 30] Lumi Life time [hr] PNG

The Numbers Store Date Avg Initial Lumi [E 30] Lumi Life time [hr] PNG [E 9] PNG Life ANG Time [E 9] [hr] Eff Emit. Prot Pbar ANG Eff Emit Pbar from RMS Length RMS Life Length Lumi [pi Bunch Life Bunch Time Life mm Length Time Length [hr] time [hr] mrad] [ns] [hr] [ns] 0. 0 ##### Prot Life- Pbar time Life@ 150 time on @ 150 Helix [hr] Prot Ineff Pbar Prot Pbar @ Store Ineff Ineff 150 Length @ 150 Ramp Sqz on [hr] [%] [%] [%] Helix [%] How ended? 7581 2/5/10 6: 26 267. 8 0. 0 9768 0. 0 2561 0. 0 1. 65 0. 0 1. 51 0. 0 7. 0 22. 6 5. 5 1. 0 1. 8 2. 9 2. 0 0. 5 7580 2/4/10 16: 53 264. 1 5. 7 9788 47. 0 2601 17. 6 13. 3 10. 4 1. 66 -22. 7 1. 51 -16. 5 11. 5 12. 2 3. 7 2. 2 1. 8 2. 7 1. 6 0. 4 12. 1 0. 3 Not Completed 7577 2/4/10 4: 43 273. 0 5. 4 9563 43. 0 2653 17. 6 12. 9 9. 6 1. 65 -13. 6 1. 53 -25. 2 9. 8 18. 9 4. 1 1. 7 1. 8 3. 3 2. 5 0. 5 5. 3 Abort 7576 2/3/10 14: 42 263. 3 5. 9 9812 38. 6 2584 19. 1 13. 2 11. 0 1. 67 -19. 6 1. 67 -32. 8 11. 7 19. 5 3. 2 0. 7 2. 0 2. 4 0. 3 12. 5 Normal 7573 2/2/10 16: 22 238. 5 5. 6 9758 51. 3 2352 15. 1 13. 5 10. 9 1. 67 -22. 6 1. 49 -26. 2 14. 6 16. 9 2. 8 0. 5 1. 8 2. 6 2. 0 0. 4 10. 7 Abort 7562 2/1/10 4: 12 257. 6 6. 0 9674 54. 3 2769 17. 7 14. 2 11. 0 1. 68 -17. 0 1. 60 -40. 7 12. 9 19. 9 3. 1 1. 0 1. 9 2. 6 2. 7 0. 1 6. 5 Tev. Quench 7559 1/31/10 12: 14 226. 4 5. 0 10007 76. 0 2440 18. 2 14. 7 7. 6 1. 68 -8. 3 1. 60 -10. 9 12. 1 27. 0 3. 1 0. 6 2. 1 2. 0 1. 5 0. 2 3. 5 Tev. Quench 7536 1/26/10 2: 18 243. 9 2. 6 8140 13. 7 2817 27. 2 12. 9 3. 7 1. 68 -60. 3 1. 63 -37. 4 12. 0 16. 9 3. 3 1. 7 1. 5 3. 3 1. 5 0. 2 25. 5 Normal 7535 1/25/10 8: 44 204. 4 6. 3 9085 68. 1 2196 20. 9 13. 0 10. 5 1. 74 -24. 9 1. 47 -37. 9 12. 1 18. 4 3. 3 0. 2 2. 1 2. 4 2. 0 0. 1 15. 9 Normal 7534 1/24/10 14: 43 234. 5 6. 0 6603 52. 7 2997 18. 2 11. 5 10. 7 1. 70 -24. 5 1. 56 -25. 7 14. 0 15. 9 2. 8 1. 3 1. 7 3. 4 1. 1 0. 2 16. 4 Normal 7533 1/23/10 18: 22 257. 8 6. 0 8196 45. 4 3228 19. 2 11. 3 10. 7 1. 73 -26. 4 1. 54 -23. 7 10. 2 14. 1 3. 8 1. 9 2. 1 3. 9 1. 8 0. 2 18. 7 Normal 7530 1/22/10 22: 56 289. 1 4. 7 9176 28. 8 3194 27. 5 14. 0 6. 9 1. 67 -27. 5 1. 54 -28. 3 13. 5 12. 4 3. 4 2. 5 1. 8 3. 5 1. 2 0. 3 14. 5 Normal 7523 1/21/10 19: 04 253. 7 6. 0 9460 75. 4 3086 15. 4 15. 6 11. 4 1. 68 -21. 4 1. 50 -67. 5 9. 5 15. 5 4. 6 2. 0 1. 9 4. 6 1. 6 0. 5 7. 0 Abort 7521 1/21/10 0: 30 281. 9 5. 3 9685 27. 5 2855 18. 3 13. 3 10. 3 1. 68 -21. 49 -19. 4 8. 4 16. 5 5. 0 1. 5 1. 8 3. 8 2. 7 0. 3 12. 2 Normal 7520 1/20/10 0: 01 267. 4 5. 8 9792 31. 9 2798 15. 5 13. 9 13. 2 1. 69 -22. 1 1. 66 -28. 4 12. 1 16. 1 3. 7 1. 9 2. 0 3. 2 3. 4 0. 3 22. 6 Normal 7516 1/19/10 3: 35 270. 3 5. 9 9120 40. 8 2930 17. 8 13. 4 11. 3 1. 68 -22. 8 1. 55 -23. 5 5. 2 15. 7 6. 9 1. 7 1. 8 4. 1 2. 4 0. 3 13. 5 Normal 7512 1/18/10 4: 35 241. 5 6. 3 9531 24. 6 2822 25. 7 15. 1 12. 4 1. 66 -20. 9 1. 88 -55. 2 9. 5 14. 8 4. 0 1. 7 3. 9 2. 1 0. 4 17. 2 Normal 7511 1/17/10 10: 27 265. 4 5. 9 9254 30. 0 2904 17. 9 13. 8 12. 4 1. 65 -14. 5 1. 76 -28. 8 8. 1 16. 2 4. 6 2. 0 1. 8 4. 2 3. 0 0. 5 16. 5 Normal 7510 1/16/10 16: 53 269. 3 5. 7 8680 30. 2 2997 17. 1 12. 8 12. 1 1. 77 -26. 2 1. 53 -18. 6 6. 0 19. 3 6. 6 3. 0 2. 2 3. 7 2. 8 0. 2 15. 8 Normal 7509 1/15/10 18: 37 251. 2 5. 8 9695 32. 9 2636 16. 6 13. 6 12. 4 1. 75 -25. 0 1. 38 -21. 6 11. 0 15. 4 3. 8 1. 6 2. 6 3. 2 2. 2 0. 2 20. 6 Normal

Lum vs Particles Initial Luminosity vs (Proton Intensity * Pbar Intensity) 400 Average Initial

Lum vs Particles Initial Luminosity vs (Proton Intensity * Pbar Intensity) 400 Average Initial Luminosity [1030 cm-2 s-1] 350 300 Last 200 Stores Last 20 Stores 250 Last Store 200 150 100 50 0 0 5 10 15 20 # Prot [109] * # Pbar [109] / [106] 25 30 35

D 0 losses Tevatron Coordinator - FNAL 12/17/2021 4

D 0 losses Tevatron Coordinator - FNAL 12/17/2021 4

CDF losses Tevatron Coordinator - FNAL 12/17/2021 5

CDF losses Tevatron Coordinator - FNAL 12/17/2021 5

Problems • • • • • C: BQn MADC failure (bad readings) Orbit file

Problems • • • • • C: BQn MADC failure (bad readings) Orbit file 262 overwritten B 1 QPM scaler bad C 4 quench during studies D 0 Q 6 ground fault (quench during dry squeeze) Abort on ramp (DA lead failure) Quench before squeeze (pbar abort kicker prefire) Leaking Kautzky @ A 11 (twice) A 2 dump breaker problem (replaced) Quench during squeeze (B 11 sep sparked twice) Stuck Katzky E 1 Cold compressor seized up (replaced) A 4 air pressure leak Quench in squeeze (B 0 losses) Store lost due to bad T: sf cable T: HF 24 noise (regulator) TRF trips (2&4) – conditioned • • Losses in squeeze and at collisions (seems to be better) Pbar blowup at collisions (seems to be almost gone) Tevatron Coordinator - FNAL 12/17/2021 6

B 0 Q 6 Tevatron Coordinator - FNAL 12/17/2021 7

B 0 Q 6 Tevatron Coordinator - FNAL 12/17/2021 7

Studies/Work Completed • Pbar only store (initial BPM & SBD issues. quench on abort:

Studies/Work Completed • Pbar only store (initial BPM & SBD issues. quench on abort: kickers not charged) • Plenty of proton onlys (orbits, tunes coupling, bumps) • • Tried new helix closure corrections Crystal collimator test Bumps through S 4 corrector elements TEL tests • Abort kicker inspections – bad crimp connectors found • Vacuum pumps replaced • 460 firmware upgrade Tevatron Coordinator - FNAL 12/17/2021 8

Studies • • • T-980 (EOS 2 -3 hours, Still) Investigate horz tune mult

Studies • • • T-980 (EOS 2 -3 hours, Still) Investigate horz tune mult (Ron) Tune space study at collisions (source of differential coupling) Bumper magnet studies. TEL 2 optimizations for abort gap cleaning (EOS 1 hr) Tevatron Coordinator - FNAL 12/17/2021 9