Sentek Technologies Joining Enviro SCAN Probes Probe Components
Sentek Technologies Joining Enviro. SCAN Probes
Probe Components Locate relevant parts for probe assembly • 20 -way probe cable connector (special order) • Cable spacer (Part No 80015) • Probe rods • Probe rod joiners (special order) • Access tubes • Access Tube joiners (Part No 22200)
Joining probe rods • Locate probe rod with probe joiner attached • Undo screw from end protruding from probe rod • Locate second probe rod with screw hole drilled in end
1 • Slide second probe rod so that the plastic fits between the two metal plates • Push probe rods together until screw holes in plates align with screw hole in plastic. • Insert screw into hole and tighten 2 3
Insert cable spacer
Joining 20 -way cable • Plug 20 -way cable joiner into plugs either side of join. • NOTE: Do not position a sensor above the probe joiner. The metal in the probe joiner may interfere with the performance of the sensor.
Joining access tube • In deep installations, the access tube may be lengthened by joining tubes during the installation procedure • The access tubes are glued together using PVC glue
• Clean the inner surface of the access tube joiner and the outer surface of the access tubes with PVC solvent • Apply PVC glue to the outer surface of one access tube and the inner surface of one end of the access tube joiner and slide together • Hold firmly in place until glue sets
• Repeat process with other access tube • NOTE: It is important to ensure that no glue seeps into the inside of the access tube, as this may hinder the installation of the probe