SCM HarnessGrounding Plans SCM Harness Sensor Bx Bx
SCM Harness/Grounding Plans SCM Harness : Sensor Bx Bx return Bx signal Bx feedback Bx Bx Return Bx Shield X shield Sensor to Preamplifier : By return 3 signal lines 3 feedback line By SCM Sensors Overall Shielding Y shield AGND Bz return 3 return line Bz 3 shielded line Z shield +10 v + 1 Overall shielding -10 v AGND Preamplifier to DFB 1 K 3 analog lines SCM_CAL 1 n. F 3 power supply lines 1 M 1 Calibration command AGND SCM Pre-amp THEMIS SCM PDR Christophe Coillot DFB CETP April 08, 2004 1
SCM Harness/Grounding Plans Harness : Sensor to Preamplifier (Overall shielding) SCM antenna J 01 1 Signal designation Bx signal Cable n° 1 AWG 26 SCM Preamp J 01 1 2 Bx shld 1 shld 2 3 By signal 2 26 3 4 By shld 2 shld 4 5 N. C. 6 Bz signal 3 26 6 7 Bz shld. 3 shld 7 8 N. C. 9 Bx return 1 26 9 10 Bx feedback 1 26 10 11 By return 2 26 11 12 By feedback 2 26 12 13 N. C. 14 Bz return 3 26 14 15 Bz feedback 3 26 15 THEMIS SCM PDR N. C. Christophe Coillot CETP April 08, 2004 2
SCM Harness/Grounding Plans Harness : Preamplifier J 02 to DFB J 02 Signal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 V+ VBx Y shield By return Bz SCM_CAL N. C. AGND Bx return X shield By Z shield Bz return N. C. Cable number 1 2 2 3 1 1 2 3 3 Wire AWG DFB Connector s 26 tsp 26 shield tsp 26 s 26 1 2 3 N. C. 5 6 7 N. C. 9 10 N. C. 12 N. C. 14 N. C. s 26 tsp 26 shield tsp 26 Harness are defined in ICD according with UCB THEMIS SCM PDR Christophe Coillot CETP April 08, 2004 3
- Slides: 3