RF Conditioning Test Bench for New Ceramic Coupler
RF Conditioning @Test Bench for New Ceramic Coupler Every result is very preliminary! A. Yamamoto, Kirk, Charles Julie, Eric Montesino, Toshihiro Matsumoto, Eiji Kako 1/Mar/2016 ILC TB Meeting Kirk 1
Specification of 40 mm Couplers Coupler (TOSHIBA) Product No. Serial No. Ceramic company Ceramic Color Coating Plating Warm #1, #2 E 42130 14 L 001 14 L 002 NGK/NTK White Ti. N Copper Cold #3, #4 E 42130 14 L 003 14 L 004 KYOCERA Gray free Copper 1/Mar/2016 ILC TB Meeting 2
Coupler Test Stand Cooling water @Dummy Load downstream upstream Warm Vac Arc #1 Pforward Pbackward Arc #2 Arc down Arc up e− #2 (peak, Q) e− #1 (peak, Q) Cold Vac 1/Mar/2016 ILC TB Meeting 3
Norma for each RF condition RF Pulse Width [μsec] RF Repetition Rate [Hz] Max. Power [k. W] 10 30 100 500 1650 (TDR spec. ) 5 5 5 1200 800 1/Mar/2016 ILC TB Meeting 4
List of Signals and I/L level Signal name I/L threshold Pfor@up, Pback@up, Pfor@down Pfor@up < 1. 3 MW, Pback@up < 10 k. W Cold / Warm Vacuum 1 ~ 2 x 10 -4 [Pa] Arc #1, #2 @waveguide 2000/6500, 2000/7000 Arc Up, Arc Down 2000/6090, 2000/6550 Electron peak-hold #1, #2 Electron charge #1, #2 Temperature #1 ~ #12 1/Mar/2016 VSWR @up, down < 1. 4 Cooling water <? ILC TB Meeting 5
Auto-conditioning Module by CERN Courtesy of Charles Julie 1/Mar/2016 We connected RFin, RFout and Vacuum output (only one ch. ) to this module. ILC TB Meeting 6
Daily Status of conditioning (1/Mar) 1/Mar/2016 ILC TB Meeting Pulse width : 10 [μsec] Repetition rate : 5 [Hz] 7
Comparison of RF Conditioning History for Both Couplers 1/Mar/2016 Date Result for Normal Ceramic Date Result for New Ceramic 18/Jan 43. 0 k. W @10μsec/5 Hz 24/Feb 56. 0 k. W @10μsec/5 Hz 19/Jan 61. 0 k. W @10μsec/5 Hz 25/Feb 66. 0 k. W @10μsec/5 Hz 20/Jan 149 k. W @10μsec/5 Hz 26/Feb 156. 0 k. W @10μsec/5 Hz 21/Jan 207 k. W @10μsec/5 Hz 29/Feb 342. 0 k. W @10μsec/5 Hz 22/Jan 312 k. W @10μsec/5 Hz 1/Mar 930. 0 k. W @10μsec/5 Hz 25/Jan 500 k. W @10μsec/5 Hz 2/Mar 26/Jan 861 k. W @10μsec/5 Hz 3/Mar 27/Jan 1200 k. W (1 hour keep) @10μsec/5 Hz 4/Mar 28/Jan 1211 k. W (1 hour keep) @30μsec/5 Hz 7/Mar 29/Jan 1215 k. W @100μsec/5 Hz 8/Mar 1/Feb 1216 k. W (1 hour keep) @100μsec/5 Hz, 604 k. W @500μsec/5 Hz 9/Mar 2/Feb 1200 k. W (1 hour keep) @500μsec/5 Hz 10/Mar 3/Feb 818 k. W (1 hour keep) @1500μsec/5 Hz 11/Mar 4/Feb 607 k. W @1650μsec/5 Hz 14/Mar 5/Feb 708 k. W (1 hour keep) @1650μsec/5 Hz 15/Mar ILC TB Meeting 8
Summary Ø Very good collaboration between CERN and KEK for this work Ø Thank you very much for Eric and Charles! Ø Auto-conditioning Module by CERN showed excellent performance (No problem!) Ø New ceramic coupler conditioning is on-going without problem Ø Necessary for Vacuum distribution module for much more convenient system How about 2 nd cycle and 3 rd cycle for coupler conditioning? Maybe we can take chance in this autumn. 1/Mar/2016 ILC TB Meeting 9