Recycler Operations and studies May 15 -21, 2009 Meiqin Xiao

Recycler Operations and studies May 15 -21, 2009 Meiqin Xiao

Cooling and Shooting for Tev stores Shot for Store # Ave. Lum. (E 30)

Cooling and Shooting for Tev stores Shot for Store # Ave. Lum. (E 30) R: SHLIFE (Hr) Stash size (E 10) Left over beam (E 10) Mining Effici. (%) Final Long. Emitt. (e. Vs) Shocttky Emiit. (H/V) pi-mmmrad) FW Emitt. (H/V) (pi-mmmrad) 7054 181. 2 500 -1100 162. 787 2. 073 98. 7 49. 7 2. 42/2. 37 1. 28/1. 32 7055 318. 2 50 -104 380. 334 10. 696 97. 2 60. 4 3. 07/3. 20 1. 23/1. 14 7056 318. 8 52 -79 378. 435 10. 988 97. 1 62. 4 3. 01/3. 18 1. 25/1. 19 7057 327. 5 90 -114 380. 219 12. 212 96. 8 64. 1 2. 80/2. 89 1. 72/1. 57 7061 203. 4 147 -348 181. 345 2. 311 98. 7 49. 0 2. 73/2. 69 1. 08/1. 08 7062 0 77 -130 386. 841 16. 761 95. 7 69. 8 3. 13/3. 22 1. 79/1. 72 7066 168. 7 >2000 153. 510 1. 700 98. 9 46. 3 2. 50/2. 61 0. 99/0. 99 7074 198. 5 1046 -2399 179. 115 1. 639 99. 1 48. 0 1. 95/1. 99 1. 23/1. 10 (Sampled every 10 min. ) After last Pbar transfer

Operation Issues • We dumped 165 E 10 beam due to the MI-access to

Operation Issues • We dumped 165 E 10 beam due to the MI-access to look at Lam 52 klixon fault • RR 129 kicker was top off with fluorinert during the MI access • R: FQC devices errors has build-up close to +/-10000(alarm limit), they were reset to 0 during Monday’s shutdown • Lost 100 E 10 of stash around 21: 15 last night with no cause found • There were 2 transfers from MI to RR with low efficiency(05/19 02: 08 2 nd transfer, 41%, 05/20 01: 55 1 st transfer , 68%) • Lost a transfer to recycler due to KPS 2 A pre-fire failed to fire. Also lost 17 E 10 of stash around 7: 35 am Wendsday morning due to KPS 2 A. • We dumped 218 E 10 beam due to the MI quad replacement

Studies 1. Cooling rate measurement with 350 E 10 beam (Lionel). • without stochastic

Studies 1. Cooling rate measurement with 350 E 10 beam (Lionel). • without stochastic cooling (but in otherwise our normal conditions, i. e. beam at 2 mm and so on) • in 3 different bunch lengths (nominal (308 bckts), nominal - 60 buckets and nominal + 60 or 120 buckets). • take data (flying wire and Schottky) for 30 minutes each time. In the case of the nominal bunch length, it would be parasitic. For the two other cases, the following transfer from the Accumulator would have to be delayed some (by max 30 minutes) since the beam would have to be squeezed or expanded before making the measurement and needs to wait to reach the appropriate beam conditions. 2. Drag rate measurement before the summer shutdown (Sasha&Lionel). • • to try (one more time) to understand the reason why we do not obtain higher drag (and cooling) rates for higher electron beam currents. ~8 hours total is needed , beams needs to be scraped to 1. 0 E 10