RD Nicotra Gebhardt Gmb H released Dr Johannes
R&D Nicotra Gebhardt Gmb. H released: Dr. Johannes Anschütz, 19. 05. 2017
Fans for Ventilation and Air conditioning FDP Centrifugal, direct driven fan with scroll casing, forward curved impeller, aluminium Fan Deck application - Double inlet - internal rotor brushless DC („EC“) motor, max. 1 k. W - Er. P 2015 and presumably 2020 compliant new
Fan solutions for industrial and process applications New P 2 M+/P 3 new • Significant price step from P 2 to P 4 P 2 P 3 P 4
Fan solutions for industrial and process applications
P 3 Headline 1: Standard standardisation
The challenge Plug fans ? Centrifugal fans with housing Possibilities for improvement are exhausted. New fan concept maximum efficiency
The challenge Plug fans ? Centrifugal fans with housing Possibilities for improvement are exhausted. New fan concept maximum efficiency
Fan efficiencies RLM – RZR - RQM +15% !
Benchmark Up to 78 % system efficiency • • The RQM Multi. Evo reaches approx. 15 % higher energy efficiency than the best freerunning or traditional fans with EC technology on the market. The measured absolute system efficiency levels reach values of up to 78% depending on the size. (system = fan, motor, frequency converter). And: Depending on the duty point, the noise emissions of the RQM Multi. Evo are up to 4 d. B lower.
Erreichbarer Wirkungsgrad Statischer Systemwirkungsgrad Ventilator, Motor, Frequenzumrichter Headline 1: Standard 78% RQM Bis 68%, mit PM motor Bis 64%, Evo Laufrad (Schaufeln profiliert), EC motor 60%, rückwärts gekrümmt, Schaufeln unprofiliert, EC- Motor
Vergleich RQM Multi. Evo - RLM Headline 1: Standard
Motor code Nominal power P N Nominal torque MN Nominal current I N Impeller speed u 2 Inverter type Inverter power P Inv k. W Nm A m/s min-1 k. W RQM F 3 -3135 -BI-QG-M AZ 150 -45 748. 3. 292 2, 1 9 5 56, 1 2950 OJ-NI-3024 2, 4 3~ / 400 V H 3 max Inverter frame size Motor type RQM… Headline 1: Standard Supply / Voltage Fan type Max. fan speed nmax RQM Typenübersicht mit PM-Motoren und integr. Elektronik RQM F 3 -3135 -BI-IG-M AZ 108 -30 747. 3. 195 1, 4 4 3, 5 42, 8 2250 OJ-NI-3015 1, 5 3~ / 400 V H 3 RQM F 3 -3540 -BI-WT-M AZ 150 -70 748. 3. 492 2, 8 14 7 59, 5 2800 OJ-NI-3030 3 3~ / 400 V H 3 RQM F 3 -3540 -BI-QG-M AZ 150 -45 748. 3. 292 2, 1 9 5 48, 9 2300 OJ-NI-3024 2, 4 3~ / 400 V H 3 RQM F 3 -4045 -BI-WT-M AZ 150 -70 748. 3. 492 2, 8 14 7 56 2350 OJ-NI-3030 3 3~ / 400 V H 3 RQM F 3 -4045 -BI-QG-M AZ 150 -45 748. 3. 292 2, 1 9 5 42, 4 1780 OJ-NI-3024 2, 4 3~ / 400 V H 3 RQM F 3 -4550 -BI-YG-M AZ 220 -55 749. 3. 392 4, 3 24 10 58, 7 2200 OJ-NI-3040 4 3~ / 400 V H 4 RQM F 3 -4550 -BI-WT-M AZ 150 -70 748. 3. 492 2, 8 14 7 46, 7 1750 OJ-NI-3024 2, 4 3~ / 400 V H 3 RQM F 3 -5056 -BI-YN-M AZ 220 -100 749. 3. 694 6, 5 44 16 61, 2 2050 OJ-NI-3055 5, 5 3~ / 400 V H 4 RQM F 3 -5056 -BI-YG-M AZ 220 -55 749. 3. 392 4, 3 24 10 53, 7 1800 OJ-NI-3040 4 3~ / 400 V H 4 RQM F 3 -5056 -BI-WT-M AZ 150 -70 748. 3. 492 2, 8 14 7 38, 8 1300 OJ-NI-3024 2, 4 3~ / 400 V H 3 RQM F 3 -5663 -BI-YN-M AZ 220 -100 749. 3. 694 6, 5 44 16 60, 3 1800 OJ-NI-3075 7, 5 3~ / 400 V H 4 RQM F 3 -5663 -BI-YG-M AZ 220 -55 749. 3. 392 4, 3 24 10 45, 2 1350 OJ-NI-3040 4 3~ / 400 V H 4 RQM F 3 -6371 -BI-YN-M AZ 220 -100 749. 3. 694 6, 5 44 16 52, 6 1400 OJ-NI-3075 7, 5 3~ / 400 V H 4 RQM F 3 -6371 -BI-YG-M AZ 220 -55 749. 3. 392 4, 3 24 10 37, 6 1000 OJ-NI-3040 4 3~ / 400 V H 4
RQM Multi. Evo Kennfeld mit PM Motor Maximale Drehzahl Baugrößen bei stat. Ventilatorwirkungsgrad über 80 % Headline 1: Standard
RQM Multi. Evo – Installation conditions Empfehlung: A/D 2 1. 8 Recommendation: diamaeter of chamber/impeller size 1. 8 Headline 1: Standard D 2 0. 1*D 2 1. 6*D 2 A
RQM installation losses Headline Installation losses = 100 % 1, 6 * D 2 losses = 0 % 2, 2 * D 2 1: Installation Standard
RQM installation conditions Headline 1: Standard • • Up to 78 % system efficiency Easy installation on the floor, wall or ceiling Simple component replacement while servicing and maintenance Easy accessibility, for example, in case of cleaning
Vergleich Schallwerte RLM vs. RQM Headline 1: Standard -1…-4 db
RQM Multi. Evo – Multiple wall configurations Headline 1: Standard
RQM Standard • • Evo impeller without diffusor in „multi“ housing Size range from 280 to 900; direct drive Possible extension up to size 900 and bigger PM motors (Domel) Versions with integrated controller (OJ) Basic version for wall mounting, bigger sizes with feet up to size 630 mm • but generally suitable for all installation positions Standard temperature range -20 to 40°C Ready for future updates of Er. P regulation 327/2011
RQM Anwendungsbeispiele • • Server cooling Control cabinets Generator cooling Replacement for RLM and RLE applications