Q 2 2014 What’s New? Hardware & Software

Q 2 2014 What’s New? Hardware & Software

What’s New? Introducing: SAMBA™ Series New 24 V Power Supply Models Uni. Logic™ Software

What’s New? Introducing: SAMBA™ Series New 24 V Power Supply Models Uni. Logic™ Software Updates

SAMBA™

SAMBA™

SAMBA™ What is Samba™? Samba is a price oriented product. Color-touch, all in one,

SAMBA™ What is Samba™? Samba is a price oriented product. Color-touch, all in one, low cost PLC. The main traits of Samba: Ø Low cost - High Performance Ø 3. 5’’ 16 bit color touchscreen Ø On Board I/Os (not expandable) Ø Programmed in Visi. Logic™ Ø Communication: Ports: supplied with 1 RS 232; 2 ports may be added: 1 Serial (RS 232/RS 485)/Ethernet & 1 CANbus Note - Unlike V 350, SAMBA™ does not support the following features: § Programmable Keys § Webserver § Profibus Slave § I/O expansion § Buzzer § Micro SD

SAMBA™ A highly compact controller with a 3. 5" graphic touch-screen and onboard I/O.

SAMBA™ A highly compact controller with a 3. 5" graphic touch-screen and onboard I/O. Samba is especially suited for small machine applications. Who are the customers for Samba™? Step up to Samba. Like Jazz, Samba is designed to give an optimal price/performance for low-end PLC and even to Smart Relay customers. These are OEMs who make small machines that have low I/O requirements. Samba is a step up for them – allowing OEMs to offer a color touch screen instead of their current text display; in a price similar to what they pay today for PLC + simple display.

SAMBA™ Are there a new marketing materials for Samba™? Yes! Ready Ø Flyer about

SAMBA™ Are there a new marketing materials for Samba™? Yes! Ready Ø Flyer about Samba™ (1 page), please order part number: DOC 17006 -A 8 Ø Magazine ad file (we can translate & add logo per request) Ø Poster file (80 X 200 cm, we can translate & add logo per request) Ø Email signature Ø Web banner Translation will be available per request Where can I find them? At Unitronics Distributors' info zone http: //www. unitronics. com/marketing/Distributers' info. zone. htm Materials soon to come: Ø 90 seconds video Ø Plexiglas display stand

Hardware SAMBA™

Hardware SAMBA™

SAMBA™ Comparison table: JAZZ-20 vs SAMBA vs V 350 Communication: Feature Jazz 20 SAMBA-SM

SAMBA™ Comparison table: JAZZ-20 vs SAMBA vs V 350 Communication: Feature Jazz 20 SAMBA-SM 35 V 350 On Board USB Port (programming) 1 x RS 232/RS 485 Add on one port: 1 x RS 232/RS 485 or Ethernet or Cloning module Add on COM 2: V 100 -17 -RS 4 (1 x. RS 485/RS 232) V 100 -17 -RS 4 -X (1 x. RS 485/RS 232 isolated) V 100 -17 -ET 2 (Ethernet) Add on COM 2: V 100 -17 -RS 4 (1 x RS 485/RS 232) V 100 -17 -RS 4 -X (1 x. RS 485/RS 232 isolated) V 100 -17 -ET 2 (Ethernet) V 100 -17 -PB 1 (Profibus slave) CANbus Add on (V 100 -17 -CAN) No Yes

SAMBA™ Comparison table: JAZZ-20 vs SAMBA vs V 350 Hardware: Feature Jazz 20 SAMBA-SM

SAMBA™ Comparison table: JAZZ-20 vs SAMBA vs V 350 Hardware: Feature Jazz 20 SAMBA-SM 35 V 350 Screen STN LCD 2 lines x 16 characters 3. 5" Touch, 320 x 240 Touch No Yes Colors (BW) 63556 Keys 61 No 5 I/O expansion No No Yes DIN Rail Mount Yes Unit is supplied without Din Rail mount clip Yes Micro SD No No Yes Buzzer No No Yes Screen STN LCD 2 lines x 16 characters 3. 5" Touch, 320 x 240

SAMBA™ Comparison table: JAZZ-20 vs SAMBA vs V 350 Software: Feature Jazz 20 SAMBA-SM

SAMBA™ Comparison table: JAZZ-20 vs SAMBA vs V 350 Software: Feature Jazz 20 SAMBA-SM 35 V 350 Programing via U 90 Ladder Visi. Logic Application Logic Size 24 K(virtual) 112 Kb 1 Mb Number of displays 60 24 1024 Images Memory size Not supported 1 Mb 6 Mb Trends & Curves Not supported 4 Trends x 2 Curves 8 Trends x 8 Curves PID Up to 4 (model dependent) 2 Up to 24 Data tables Not supported RAM 32 Kb/ Flash 16 Kb RAM 120 Kb/ Flash 256 Kb Alarms Not supported 16 64 String Library Not supported Up to 8 Libraries Up to 16 Libraries

SAMBA™ Comparison table: JAZZ-20 vs SAMBA vs V 350 Software: Feature Jazz 20 SAMBA-SM

SAMBA™ Comparison table: JAZZ-20 vs SAMBA vs V 350 Software: Feature Jazz 20 SAMBA-SM 35 V 350 Operands - MB 256 512 8192 Operands - MI 256 4096 Operands - ML Not supported 32 512 Operands - MF Not supported 24 64 Operands - DW Not supported 32 256 Operands - Timers 64 32 384 Operands - Counters Not supported 16 32 Operands - XB Not supported 64 1024 Operands - XI Not supported 32 512 Operands - XL Not supported 16 256 Operands - XDW Not supported 16 64

Quick Review SAMBA™

Quick Review SAMBA™

HMI & General Info SAMBA™

HMI & General Info SAMBA™

NEW 24 V Power Supply New DIN-rail Power Supplies UAP-24 V 24 W UAP-24

NEW 24 V Power Supply New DIN-rail Power Supplies UAP-24 V 24 W UAP-24 V 60 W UAP-24 V 96 W P. SUP, 120 -370 VDC-24 V/1 A, DIN. R P. SUP, 120 -370 VDC-24 V/2. 5 A, DIN. R P. SUP, 120 -370 VDC-24 V/4 A, DIN. R

Software Updates - Uni. Logic This release introduces support for: Ø The new UIS-04

Software Updates - Uni. Logic This release introduces support for: Ø The new UIS-04 PTN I/O temperature module Ø New Long-range Local Expansion Adapters enabling you to link up to 85 I/O modules to a single Uni. Stream controller Ø Additional HMI languages, and much more Note that you must update the Uni. Stream OS to support the features. Known Issue - Only one *. gif may be placed on a screen. If there is more than one, Uni. Logic will display a compilation error

Software Updates - Uni. Logic New Temperature I/O Module - UIS-04 PTN provides 4

Software Updates - Uni. Logic New Temperature I/O Module - UIS-04 PTN provides 4 RTD inputs supporting PT 100, NI 120, and Resistance UIS-04 PTN

Software Updates - Uni. Logic New Long-Range Local Expansion Adapters - UAG-XKPLxxx: New Long

Software Updates - Uni. Logic New Long-Range Local Expansion Adapters - UAG-XKPLxxx: New Long Range Local Expansion adapter. (Available with 6 or 12 meter [20 or 40 feet cable) You can use Short or Long Range Local Expansion Adapters to connect a Uni. Stream™ controller to a row of I/O modules located on a DIN-rail. Daisy-chain up to 5 Local I/O Expansion Adapters to one controller to further increase the number of I/O modules up to 85 Short Range Powered Adapter Long Range Expansion Adapter Short Range Powered Adapter

Software Updates - Uni. Logic New Languages - Now, supports 10 new languages: Ukrainian,

Software Updates - Uni. Logic New Languages - Now, supports 10 new languages: Ukrainian, Romanian, Hungarian, Georgian, Slovenian, Slovak, Serbian, Latvian, Lithuanian, Estonian, Filipino and Swedish. In addition, you can edit Language strings directly in the Language table. You can also export a Language file, translate or edit it in Excel, and then import it back into the project

Software Updates - Uni. Logic Data Tables: Direct Edit- Within Uni. Logic, you can

Software Updates - Uni. Logic Data Tables: Direct Edit- Within Uni. Logic, you can now click on a Data Table cell to directly enter or edit values This version also supports Export and Import from Excel

Software Updates - Uni. Logic HMI Screen Jumps: Ø Displays now load faster Ø

Software Updates - Uni. Logic HMI Screen Jumps: Ø Displays now load faster Ø You can select whether to Show Hourglass in a Screen's Properties to display an hourglass during screen transitions New HMI Editor features - This version supports a number of new features: Ø Apply Layout: Select multiple HMI elements of the same type/ list of text/range, and then right-click to apply font, font alignment, and other attributes Ø Copy & Paste of object now retains the object’s location Ø Changing font properties causes all future elements to use the new setting Ø Duplicate Screens via right-click on the screen in Solution Explorer

Software Updates - Uni. Logic Firmware Management - When you download a project, Uni.

Software Updates - Uni. Logic Firmware Management - When you download a project, Uni. Logic now checks to see if the firmware in the controller is compatible with the Uni. Logic version In addition, the PLC tab on the program ribbon offers Firmware Management tools: Ø The Firmware Manager which locates all firmware files on your PC Ø Update Firmware, which to connects to the Unitronics website and downloads any new firmware releases

Software Updates - Uni. Logic Ethernet Favorites - When you select Ethernet PC-PLC Communications,

Software Updates - Uni. Logic Ethernet Favorites - When you select Ethernet PC-PLC Communications, you can use IP Favorites. This is a global file that is available in all of your Uni. Logic projects

Software Updates - Uni. Logic New Sound Library- Actions now offer a System Sound

Software Updates - Uni. Logic New Sound Library- Actions now offer a System Sound Library Keep last Communication method - When you establish PC-PLC communications, Uni. Logic will continue to use the last communication channel you used, whether via Ethernet or USB, for as long as that channel is valid. You can change the channel by selecting Communications from the PLC tab on the ribbon

Software Updates - Uni. Logic New Ladder Functions - This version includes a number

Software Updates - Uni. Logic New Ladder Functions - This version includes a number of new Ladder functions: Ø Reset Numeric Ø Set Date/Time from Ladder Ø Copy Byte Ø String compare 8 -16 -32 Ø Find and replace in array/buffer Ø Swap: 16/32 bit tags Ø Swap Array/Buffer Toggle Online Test Mode - Press F 9 to toggle On-Line Mode on and off

Software Updates - Uni. Logic Data Tables - Indexed Data Tables (DTIs) offer new

Software Updates - Uni. Logic Data Tables - Indexed Data Tables (DTIs) offer new Ladder functions: Ø Find Value in DTI Column Finds a value in a column and writes the row index number into a data tag Ø Copy Array to Column in DTI Copies an array, or part of an array, into a specified column in a Data Table column Ø Copy DTI Column into Array Copies data from a Data Table column into an array Ø Copy Column to Column in DTI Reads data from one DTI column and writes it into another column. The columns may be in different Data Tables Ø Write value to DTI Column Writes values into a column in a DTI. You can use it to initialize a column Ø Find Values in DTI Row Searches a range of rows for data that matches the current contents of a struct In addition, you can find all locations where a Data Table is referenced by right-clicking the Data Table in the Solution Explorer.

Software Updates - Uni. Logic State Machine Button - This button enables you to

Software Updates - Uni. Logic State Machine Button - This button enables you to use the value of a register to display variable text within a button, and to drive multiple Actions via the button

Software Updates - Uni. Logic Keyboard on Screen - A new system tag, Keyboard

Software Updates - Uni. Logic Keyboard on Screen - A new system tag, Keyboard Bit is ON when the keyboard is displayed on the Uni. Stream Panel. Keyboard Bit is located in the System> General> struct Top of Region - A new icon enables you to jump to the top of the region you are editing

Software Updates - Uni. Logic Download Media changes - As of this version, project

Software Updates - Uni. Logic Download Media changes - As of this version, project media Audio files will download to SD card. Note that in older projects, audio was stored in Flash memory. When these projects are edited in this version and up, any previous audio files will continue to be stored in Flash; however any added audio files will download to SD card.

Software Updates - Uni. Logic Initial Values at Download - When you check Retain,

Software Updates - Uni. Logic Initial Values at Download - When you check Retain, you have the option of entering an Initial Value, If you: Ø Enter a value, that value will be downloaded with the application first time the tag is downloaded to the PLC Ø Do not enter a value, the tag value will be initialized to 0 the first time the tag is downloaded to the PLC Note that if you change a tag's Data Type, the tag will be initialized to 0 at download

Software Updates - Uni. Logic Rx Terminator - You can use the members of

Software Updates - Uni. Logic Rx Terminator - You can use the members of the struct of COM Modules, the CPU RS 485 port or the struct of the USB port (set to Serial Communications) to monitor incoming strings for terminators such as length, silence, and ETX characters

Thank You!

Thank You!