Pure IP PBX KXTDE 600 MPR 2 00
Pure IP PBX KX-TDE 600 MPR 2. 00 Panasonic Communications CO. , LTD.
Pure IP-PBX KX-TDE Series “ Product Line Up TDE 100/200 MPR 1. 00 Version TDE 100/200 (MPR 1. 0) TDE 100/200 (MPR 2. 0) TDE 600 (MPR 2. 0) TDE 100/200 MPR 2. 00 Main Function TDE 600 MPR 2. 00 - Peer to Peer Communication - KX-NT 300 Series IP-PT - SIP Phone Compatible - KX-TDA 0177 (CSLC 16) - Improved Built-in SVM 2 - KX-TDA 0192/4 (ESVM) - 8 Digits VM Integration - Support T 38 (ITU standard for sending FAX) The same as TDE 200 MPR 2. 0/TDA 600 MPR 5. 0 New activation key.
KX-TDE 600 System Highlights “ Build - up system (Flexible system: same as TDA 600) Inherent TDA 600 MPR 5. 0 Features. Inherent TDE 100 MPR 2. 0 Features. Easy upgrade from TDA 600 to TDE 600 (Change EMPR card to IPCEMPR card) TDA 600 Hardware products compatible with TDE 600. TDE 100 Activation keys compatible with TDE 600. CA (NCP) feature is not supported. TDE 600 does not support build-in SVM. New activation key for TDE 600. Support KX-NT 3 xx Series Support KX-DT 3 xx Series PA: TDE 600 supports PA 1. 8 only. (Do not use PA 1. 7 or early version. )
“ KX-TDE 600 System Highlights NT 300 TDE 100/200 Series Activation Key NT 136 Vo. IP/SIP Router TDA 0470 DLC DHLC IPCEMPR DSP MPR 2. 0 PCMC T 7600 DT 300 TDA 600 MPR 5. 0 Features TDE 100 MPR 2. 0 Features NT 300
KX-TDE 600 Shelf KX-TDE 600 Basic Shelf Difference from TDA 600 - MPR Card - Front cabinet “ KX-TDE 620 Expansion Shelf Difference from TDA 620 - Front cabinet
KX-TDE 600 Shelf (Build up) The same concept as the TDA 600 KX-TDE 620 KX-TDE 620 KX-TDE 600 Entry Medium-1 Medium-2 Full
“ KX-TDE 600 Shelf The same as the TDA 600 4 x Physical Shelf 1 x Virtual Shelf
“ KX-TDE 600 Virtual Slot 4 x Virtual Slot Trunk 4 x Virtual Slot Extension The same as TDE 100/200. Total Max 8 x Virtual Slot
“ KX-TDE 600 Max. Slot TDE 600+ TDE 620 x 1 TDE 620 x 2 TDE 600+ TDE 620 x 3 System Max 18 29 40 51 Trunk Max 14 24 34 40 10 20 30 40 4 4 4 4 10 21 32 43 Physical Slot Virtual Slot Extension Max. Physical Slot Virtual Slot Physical Slot
“ KX-TDE 600 Terminals (Trunk) TDE 600 Trunk Max. TDA 600 640 32 (2 x SIP G/W-16) - 0 - 32 (2 x V-G/W-16) - 640 (40 Slots) LCOT/BRI Traditional 640 (40 Slots) PRI 30/E 1 Traditional 600 (20 Slots) PRI 23 Traditional 460 (20 Slots) T 1 Traditional 480 (20 Slots) SIP G/W Virtual (MPR) Traditional Max. H. 323 G/W Virtual (MPR) Traditional Max.
KX-TDE 600 Terminals (Trunk) TDE 600 + TDE 620 x 1 TDE 620 x 2 TDE 620 x 3 192 (*1) 352 (*2) 512 (*3) 640 32 32 32 160 320 480 640 150 300 450 600 115 230 345 460 120 240 360 480 160 320 480 640 TDE 600 Trunk Max. Virtual Max SIP IP-G/W Traditional Max. Analogue BRI PRI 30/E 1 PRI 23 T 1 IP-G/W “ (*1) 192: 160 (BRI x 10) + 32 (Virtual) (*2) 352: 320 (BRI x 20) + 32 (Virtual) (*3) 512: 480 (BRI x 30) + 32 (Virtual)
“ KX-TDE 600 Terminals (Extension) TDE 600 TDA 600 1152 640: TDA 0172 x 20 128: SIP (32 x 4 Slot) 384: TDA 6178 x 16 Slot Virtual (MPR) 64 (2 x V-IPExt-32) 1120 640 (40 Slot) 672 640 128 (4 x V-SIP-32) - 0 - Max. 128 - PT Traditional 640 SLT Traditional Extension Max IP-PT (MGCP) Traditional Max. SIP Ext. Virtual (MPR) Traditional PS (w/o MEC / w/ MEC) - 960 (40 Slots x SLC 24) 512/512 256/512
“ KX-TDE 600 Terminals (Extension) TDE 600 System Max. w/ DXDP w/o DXDP Virtual Max SIP IP-PT Traditional Max. w/ DXDP w/o DXDP SLT Max PT Max. PT w/ DXDP PT w/o DXDP IP-PT CS PS (w/o MEC/ w/ MEC) 432 368 128 64 304 240 256 160 TDE 600+ TDE 620 x 1 TDE 620 x 2 TDE 620 x 3 736 1008 1152 608 848 992 128 128 128 64 64 64 608 880 1120 480 720 960 512 640 640 320 480 640 32 64 96 128 512/512
“ KX-TDE 600 Compatibility - Compatibility with TDA 600 option cards. (Trunk/System) Card TDE 600 TDA 600 Card ELCOT-16 (TDA 6181) E 1 (TDA 0188) CID/PAY 8 (TDA 0189) CID (CO: TDA 0193) BRI-8 (TDA 0288) BRI-4 (TDA 0284) PRI (TDA 0290) IP-GW 4 (TDA 0480) IP-GW 4 E (TDA 0484) IP-GW 16 E (TDA 0490) Yes Yes No Yes Bus-Master (TDA 6110) Yes Master-Sub (TDA 6111) Yes Yes EMEC (TDA 6105) IPCMEC (TDE 0105) No Yes No PSU-M (TDA 0104) PSU-L (TDA 0103) Yes Yes Yes Yes TDE 600 TDA 600 TDE 600 does not support. - LCOT-4 (TDA 0183) - LCOT-8 (TDA 0180)
“ KX-TDE 600 Compatibility - Compatibility with TDA 600 option cards. (Extension) Card TDE 600 TDA 600 DHLC-8 (TDA 0170) DLC-8 (TDA 0171) DLC-16 (TDA 0172) SLC-8 (TDA 0173) CSLC-16 (TDA 0177) ESLC-16 (TDA 6174) EMSLC-16 (TDA 6175) ECMSLC-24 (TDA 6178) CS-I/F (TDA 0144/0143) Echo-16 (TDA 6166) CTI-LINK (TDA 0410) IP-Ext-16 (TDA 0470) Ext. CID (TDA 0168) Yes Yes Yes No (*1) Yes Remote (TDA 0196) Yes OPB-3 (TDA 0190) DPH-4 (TDA 0161) DPH-2 (TDA 0162) MSG (TDA 0191) E-SVM-2 (TDA 0192) E-SVM-4 (TDA 0194) Yes Yes Yes Yes Yes Yes Yes *1: IPCEMPR Card has the CTI link port. TDE 600 does not support. - SLC-16 (TDA 0174) - SLC-16 (TDA 0175) - ECHO-16 (TDA 0166)
“ KX-TDE 600 Compatibility - Compatibility with TDE 100/200 Activation keys. Activation key TDE 600 TDE 100 2 -IP Trunk (NCS 4102) 4 -IP Trunk (NCS 4104) Yes No (*1) Yes 1 -IP Soft-/IP-PT (NCS 4201) 8 -IP Soft-/IP-PT (NCS 4208) Yes No (*1) Yes 1 -IP-PT (NCS 4501) 8 -IP-PT (NCS 4508) Yes No (*1) Yes 1 -SIP Phone (NCS 4701) 16 -SIP Phone (NCS 4716) Yes No (*1) Yes Feature Enhancement (NCS 4910) Feature Enhancement (NCS 4950) No Yes No *1: TDE 100/200 MPR 2. 01 will support. New activation keys.
“ KX-TDE 600 Compatibility - Compatibility with TDE 100/200 options. TDE 600 TDE 100 DSP-16 (TDE 0110) DSP-64 (TDE 0111) Vo. IP Encryption SD card (TDES 01) Vo. IP Encryption SD card (TDES 61) Yes No Yes Yes No
“ KX-TDE 600 Compatibility - Compatibility with NCP 500/1000 TDE 600 NCP All Hardware of TDE 600 All Hardware of NCP Yes No No Yes All Activation products of TDE 600 All Activation products of NCP Yes No No Yes
System Connection TDE 600 & TDE 620 A cable is packed in BUS-M (TDA 6110), BUS-M-Sub (TDA 6111) TDE 620/TDA 620 Software should be 2. 000 or later. TDE 620/TDA 620 Cable TDE 600 Power unit LPR Cards TDE 600 TDA 6111 (BUS-M-Sub) TDA 6110 (BUS-M)
Activation Key
Activation Key “ - Issuing TDE 600 activation key procedure is the same as TDE 100/200. URL: https: //eww. netreg. panasonic. co. jp/kms/
KX-TDE 6101 IPCEMPR KX-TDE 0105 IPCMEC
KX-TDE 600 IPCEMPR (TDE 6101) - KX-TDE 6101: MPR card for TDA 600. (KX-TDE 600 has KX-TDE 6101) -KX-TDE 0105 Memory Expansion Card for IPCEMPR “ Build-in Memory Card
“ KX-TDE 0105 (IPCMEC) Feature TDE 600 MPR 2. 0 Items 4 Party Conference With Broadcasting. System Speed Dial Station Speed Dial 100/Ext. Hotel-SMDR for check out. TDA 600 MPR 5. 0 W/o TDE 0105 W/o MEC W/MEC Yes No Yes 1000/Tenant x 32 Yes No Yes 4000 Calls 8000 Calls No 8000 Calls 1000 Calls 4000 Calls Quick Dial 8 Digit, 4000 entries Yes Yes Max. Number of PS 512 256 512 SDMR buffer
Procedure adding IPCMEC “ The procedure detailed below is for your reference regarding the addition of a IPCMEC card to a previously installed TDE 600. 1. Save the current system data from the TDE to the SD card 2. Save the current system data from the SD card to your PC. 3. Power off the TDE and remove the preinstalled MEC card. 4. Install an IPCEMEC to the TDE. Important 5. Power on with initializing steps. 6. Connect the PCMC and initialize the TDE. 7. Upload the system data to the TDE. Note: When the preinstalled memory card is removed, all recorded SMDR data will be lost. Therefore, it is recommended to output the SMDR data before removing the preinstalled memory card.
TDE 600 Software
TDE 600 Software TDE 600 supports, TDA 600 MPR 5. 0 Features. - KX-TDA 0158 (8 ch-CS) - KX-TDA 6178 (24 -SLT) - 8 digits VM integration - KX-TDA 0192/4 (ESVM) - Moving From SVM to DISA - High Quality OGM Record to ESVM TDE 100 MPR 2. 0 Feature. - T. 38 “
TDE 600 Software Modified/New Functions/Features “ Modified/New Functions/Features 1 VM-Group Ext. number can be assigned as transfer re-call destination. 2 Intercept function performs an extension which set call forward to CO. 3 Auto recovery function for Busy-out (Analogue line). 4 Two CLIP on an Extension. 5 Check-OUT not ready mode (Hotel feature) is supported. 6 System error activates an external relay. 7 PRI CNIP with the name of extension.
“ Software Enhancement Plan Transfer re-call to VM-Group. Intercept for Call. FWD to CO. Busy-out Auto recovery function. Two CLIP on an Extension. Check-OUT not ready mode. System error activates an external relay. PRI CNIP TDE 600 NCP 500 NCP 1000 TDA 30 2. 0 1. 0 (5. 0) (? ) (3. 0) 2. 0 (? ) (5. 0) (? ) (3. 0) 2. 0 1. 0 (5. 0) (? ) (3. 0) 2. 0 1. 0 N/A (5. 0) (? ) (3. 0) ( ) = Planed MPR version TDA 100 TDE 100 TDA 600 TDA 200 TDE 200
PCMC for TDE 600
PCMC for TDE 600 Please use U-PCMC Ver. 4 “
PCMC for TDE 600 Now file “
PCMC for TDE 600 Connect “
Upgrade TDA/TDE to TDE 600
“ Upgrade to TDE 600 Update from TDA 600 The following items are necessary for the upgrade: Model/Name Description KX-TDE 6101 (IPCEMPR) IP Convergence Main Processing Card The main processing card for controlling the Pure IPPBX (KX-TDE 600). This card comes with an SD Memory Card and 2 ferrite cores included. KX-TDE 0110 (DSP 16) 16 -Channel Vo. IP DSP Card Digital signal processor (DSP) cards to be mounted on the IPCMPR/IPCEMPR card. Depending on the number and the type of IP trunks and IP telephones you wish to use, either the DSP 16 or DSP 64 card is selected to be installed. Note The following activation keys are pre-installed: 4 -Channel IP Trunk Activation Key: 1 for DSP 16; 4 for DSP 64 8 -Channel IP Proprietary Telephone Activation Key: 1 for DSP 16; 4 for DSP 64 KX-TDE 0111 (DSP 64) 64 -Channel Vo. IP DSP Card
“ Upgrade to TDE 600 System data converter (By PCMC) We can upgrade from TDA 100/200/600/TDE 100/200 to TDE 600. The origin PBX System data is only versions of TDA 100/200 TDA 600 (MPR 5. 0 xxx), TDE 100/200 (MPR 2. 0). TDA 600 MPR 5. 0 TDE 100/200 MPR 2. 0 PCMC Data Converter TDE 600 System Data
“ Upgrade to TDE 600 Upgrade from TDA 100/200 MPR x. x, TDA 600 MPR 1. 0, TDE 100/200 MPR 1. 0 to TDE 600. TDA 100/200 MPR x. x TDA 600 MPR 3. 0 TDE 100/200 MPR 1. 0 Not Possible PCMC Data Converter Data Convert PCMC Data Converter TDA 600 MPR 5. 0 TDE 100/200 MPR 2. 0 TDE 600 System Data
Upgrade to TDE 600 “ PCMC data convert conditions - SLC 16 is converted to ESLC 16 automatically. - MSLC 16 is converted to EMSLC 16 automatically. - LCOT 16 is converted to ELCOT 16 automatically. The following card has to be removed and the card data has to be deleted before system data convert. - LCOT-4 (TDA 0183) - LCOT-8 (TDA 0180) - Vo. IP-4 (TDA 0480) - ECHO-16 (TDA 0166) - CTI Link card (TDA 0410) - Any card in Slot 11 TDE 600 requirements - Card configuration of TDE 600 should be same as TDA/TDE. - If the MEC card is installed in the TDA, IPCMEC should be install.
Upgrade to TDE 600 “ Note: The TDA SD memory card (TDA 30/100/200: 32 M, TDA 600: 64 M) used in the TDA cannot be used TDE 600 (128 M). The SD memory card contains software for all the processes of the PBX and all the customer data. It can be easily removed and taken away from the PBX by a third party. Therefore, do not allow un-authorized access to prevent data leakage. To prevent data leakage, render the SD Memory Card physically unusable before disposal.
Upgrade to TDE 600 Data Reset After Upgrade • Incoming Call Log • Outgoing Call Log (including Last Number Redial) • Message Waiting • SMDR • Advice of Charge (AOC)/Pay Tone • Hospitality guest billing data • ICD Group monitor log for supervisor • PBX date and time • Timed Reminder • LPR Timed Update time • Daily test start time • PT handset/headset volume • PT SP-PHONE volume • PT ring volume • PT display contrast • ICD Group login status “
Upgrade to TDE 600 “ • ICD Group login status (All extensions are set to Login by default. ) • ICD Group Ready/Not Ready status (All extensions are set to Ready by default. ) • Live Call Screening (LCS) On/Off • Hands-free Answerback status • Absent Message status of extensions (Absent Message data itself is not cleared. ) • FWD/DND status (FWD destinations are not cleared. ) • Extension Lock/Remote Extension Lock • Extension PIN Lock/Extension PIN Lock counter • Verified Code PIN Lock/Verified Code PIN Lock counter • Password Lock counter for Remote System Programming • PBX Error Log • Digital Trunk Error Report data
Upgrade Steps
Upgrade to TDE 600 “ 1 - Back up the current system data. 2 - Back up the current OGM files 3 - Open the current system data by batch mode. 4 - Delete the following card from the system data - LCOT-4 (TDA 0183) - LCOT-8 (TDA 0180) This steps is operated by the - Vo. IP-4 (TDA 0480) PCMC, but PCC recommends - ECHO-16 (TDA 0166) this step by manually. - CTI Link card (TDA 0410) - Any card in Slot 11 5 - Save the system data.
Upgrade to TDE 600 “ 6 - Convert the saved system data file for use with the TDE 600. 6. 1 - Open U-PCMC 4. 0. 6. 2 - Click 6. 3 - Select “PBX” - TDA 600 → TDE 600 - TDE 100/200 → TDE 600 6. 4 - Select “By file” 6. 5 - Click “Next”
Upgrade to TDE 600 “ 6. 6 - Select source file (TDA 600 MPR 5. 0 or TDE 100/200 MPR 2. 0) and click “OK” 6. 7 - Select destination file and click “OK” The source file is automatically converted the TDE 600 system data. 7 - Set up a new TDE 600, or TDA 600 [TDA 600] Remove the current MPR card from the TDA 600 and Install the IPCEMPR Card with either the DSP 16/DSP 64 Card mounted, in the TDA 600. 8 - Slide the System Initialize Switch to the "SYSTEM INITIALIZE" position. 9 - Turn on the power to the PBX. 10 - Connect the U-PCMC to the TDE 600. 11 - Quick set up. 12 - Transfer the converted TDE 600 data to the TDE by U-PCMC.
“ Upgrade to TDE 600 13 - Activate the user DGSYS from the PC. Select “Utility” - ”System Reset” - “Reset by the Command”. 13. 1 - Select Important 13. 2 - Click “OK”
“ Upgrade to TDE 600 [ Final settings ] SD Card - PGMPR 2. 0 - DGSYS (2. 0 User) - DGSYS_SUB (2. 0) MPR. 2. 0 TDA Flash ROM - PGMPR 2. 0 - DGSYS (2. 0 User)
Upgrade Steps (TDA 620 to TDE 620)
Upgrade from TDA 620 to TDE 620 -1 1 - Check the present BUS-S software version. Should be 2. 0 xx “
Upgrade from TDA 620 to TDE 620 -2 “ 2 - Transfer the BUS-S software (2. 0 xx) to the SD card. pbuss_v 02 xx. bin SD Card - PGMPR 2. 0 - DGSYS (2. 0 User) - PBUSS 2. 0 MPR. 2. 0
Upgrade from TDA 620 to TDE 620 -3 3 - Set the TDA 620 to “OUS” mode. Click to “OUS” “
Upgrade from TDA 620 to TDE 620 -4 4 - Transfer the BUS-S software (2. 0 xx) to the TDA 620. 4 -1 Select 4 -2 Click 4 -4 Click 4 -3 Select “
Upgrade from TDA 620 to TDE 620 -5 “ 4 -5 Click 4 -6 Click Present Software version
Upgrade from TDA 620 to TDE 620 -6 “ 4 -7 Click 4 -8 Click “OUS”
Upgrade from TDA 620 to TDE 620 -7 4 -9 Click “
Upgrade from TDA 620 to TDE 620 -8 5 - Set the TDA 620 to “INS” mode. Click to “INS” “
Upgrade from TDA 620 to TDE 620 -9 6 - Check the present BUS-S software version. Should be 2. 0 xx “
Thank you very much !
- Slides: 58