PROFIBUS - Token Ring logical token ring between the master stations active stations, master

PROFIBUS - Token Ring logical token ring between the master stations active stations, master devices PLC PLC PROFIBUS M Sensor Drive Actuator Sensor passive stations, slave devices M T Drive Transmitter

Open Configuration with PROFIMAP f on c m te Sys ion t a r

Open Configuration with PROFIMAP f on c m te Sys ion t a r igu Profimap PROFIBUS configuration tool PLC Device Data Base Files GSD-file PROFIBUS - DP Field device M I/O Sensor Drive Transmitter Field device

Open Configuration with PC Sy Based Control st PROFIBUS configuration tool em co nfi

Open Configuration with PC Sy Based Control st PROFIBUS configuration tool em co nfi PC Based Control gu on Device Data Base Files GSD-file PROFIBUS - DP Field device M I/O Sensor ra ti Drive Transmitter Field device

A 1 SJ 71 PB 92 D Module Details Hardware Configuration A 1 SJ

A 1 SJ 71 PB 92 D Module Details Hardware Configuration A 1 SJ 71 PB 92 D Melsec Profi. Map Configuration Software #### ### #### Mode Profi. Map Cable Mode Selection – 0 = On-Line * – 1 = PRM Set – 2 = Test – E = Online # RS-232 -C To Profibus DP Network Profibus I/F Bus Termination On Off * 32 I/O byte mode #244 I/O byte mode (version BE or later) Bus Terminator Resistance

AJ 71 PB 92 D Module Details Hardware Configuration AJ 71 PB 92 D

AJ 71 PB 92 D Module Details Hardware Configuration AJ 71 PB 92 D Melsec Profimap Ver 2. 0 up #### ### #### Mode Profi. Map Cable RS-422 To Profibus DP Network Profibus I/F Bus Termination On Off Mode Selection – 0 = On-Line * – 1 = PRM Set – 2 = Test – E = Online # * 32 I/O byte mode #244 I/O byte mode Bus Terminator Resistance

DP Master Module Configuration 4 Has the capability to support 60 Slave Units 4

DP Master Module Configuration 4 Has the capability to support 60 Slave Units 4 Each Slave can address 32 Bytes Input Data / 32 Bytes Output Data 4 Extended capacity up to 244 I/O bytes * per slave 4 Diagnostic Area for Slave fault Information 4 Diagnostic Buffer for master module faults 4 On-Board Termination resistor 4 Supports Global Functions * On An. S module versions BE or later, all AJ 71 PB 92 D versions

Profi. Map Configuration Software

Profi. Map Configuration Software

Many devices can be added, as shown

Many devices can be added, as shown

The “Create POU” button is a direct link to MM+

The “Create POU” button is a direct link to MM+

A POU is created as an ascii file

A POU is created as an ascii file

The ascii file can be imported from the Project menu, as shown. Page 118

The ascii file can be imported from the Project menu, as shown. Page 118

A POU has been created, in Melsec IL, containing, TO/FROM statements, for all stations

A POU has been created, in Melsec IL, containing, TO/FROM statements, for all stations on the Profibus network. Buffer memory is allocated in ascending station number order. Page 119

The information filled in at this stage, are the source/destination for the TO/FROM instructions

The information filled in at this stage, are the source/destination for the TO/FROM instructions in the POU.

Mitsubishi and Profibus DP 4 Mitsubishi have the following devices that support the Profibus

Mitsubishi and Profibus DP 4 Mitsubishi have the following devices that support the Profibus DP Protocol: – – – – – FX 0 N/FX 2 N PLC with FX 0 N-32 NT-DP add on block FX 2 N-32 DP-IF I/O adaptor interface E range of Operator Interfaces FR-PBM Inverter Drive Interface (A 024/A 044/A 140/A 240) A 500 Inverter Drives (with FR-A 5 NP interface) Remote I/O AJ 95 TB 3 -16 D 16 way input AJ 95 TB 2 -16 T 16 way trans output AJ 95 TB 32 -16 DT 8 way input / 8 way output MT Series I/O digital and analogue I/O

Mitsubishi Profibus DP Connections Profibus I/F 9 Pin 3 Profibus DP A(1 S)J 71

Mitsubishi Profibus DP Connections Profibus I/F 9 Pin 3 Profibus DP A(1 S)J 71 PB 92 D Master Module 8 RS 422/485 Earthing not shown see earlier slides . . 3 8 FR - PU 02 E Pr 7 . . 3 8 . . . Up to 32 Nodes per Master Module without repeaters . 3 8 FR-PBM 7 8 9 4 56 1 23 A 500 Drives + FR-A 5 NP FR - PU 02 E Pr 7 7 8 9 4 56 1 23 Digital/ Remote Analogue I/O Remote I/O A 024/A 044 A 140/A 240 Drives FX 0 N/FX 2 N PLC + FX 0 N-32 NT-DP Remote I/O FX 2 N 32 DP-IF MAC E range + standard I/O, + IFC PBDP analogue, high speed I/P Blocks

Mitsubishi I/O Options Fixed Digital I/O Blocks Remote I/O AJ 95 TB 3 -16

Mitsubishi I/O Options Fixed Digital I/O Blocks Remote I/O AJ 95 TB 3 -16 D 16 way input AJ 95 TB 2 -16 T 16 way transistor output AJ 95 TB 32 -16 DT 8 way input / 8 way output

Mitsubishi I/O Options MT Series Flexible I/O Blocks Analogue Module - 4 inputs and

Mitsubishi I/O Options MT Series Flexible I/O Blocks Analogue Module - 4 inputs and 4 outputs are available. 12 bit resolution Digital Module - 8/16 inputs and 4/8/16 outputs are available. Outputs in relay or transistor types Base Module - 16 modules (up to 8 analogues) can be connected

Mitsubishi I/O Options FX 2 N 32 DP-IF - Interface Solution FX 2 N

Mitsubishi I/O Options FX 2 N 32 DP-IF - Interface Solution FX 2 N 32 DP-IF allows standard FX 0 N/2 N extension blocks to be coupled together as a Profibus DP I/O station FX 2 N 16/32/48 Digital I/O blocks FX 0 N 8/16 Digital I/O blocks FX 2 N 4 DA/AD 4 channel analogue output/input blocks FX 2 N 4 AD-PT 4 channel PT 100 sensor input FX 2 N 4 AD-TC 4 channel thermocouple input Standard FX blocks can be used with an adapter cable

Questions?