Precautious -> After well informed, use this device. Keeping after use -> Check the

Precautious -> After well informed, use this device. Keeping after use -> Check the battery size. -> When keeping, keep the product after take out needle&puff. -> Assigned needle, ONLY. ->Don’t wipe with chemical substance, cleaner. -> Healthy, and no trouble skin use, ONLY. ->Keep in area well ventilated. -> Don’t use on dermatitis, acne, allergic trouble skin etc. ->Don’t use on status of high temperature, humid and direct sun light. ->If you are in doubt on your skin status, show the doctor before use. ->Keep this product where children & pets cannot reach. -> Before use, clean hands and skin area to use. -> Use assigned solution to absorb, outside of that, consult with doctors or pharmacist before use. -> While using, if seeing skin rash, inflammation, allergy etc. , stop to use promptly, and then take treatment from doctors or pharmacist. -> Scrap used needle certainly, the needle is disposable. ->Shouldn’t discompose or remodel. ->Strong pressure while using can make speed down or stop. -> Don’t use around eyes. -> Don’t use by teenager or children. ->Don’t push the button with strong power. ->Don’t use with wet hands, and don’t put the device on wet area. For Use Cleansing-Straighten Skin with Toner after washing- Spread Solution- Needling- Mask Pack- Message with Jelly Puff. Rejuvenation Cream-Sun screen.

Needle Change 1. Push and put locking loop of needle set fitting with the

Needle Change 1. Push and put locking loop of needle set fitting with the right direction. 2. Lock the needle set into the arrow direction. 3. Grab and take out lid of the needle set. Removal is vice-versa. Guide Change 1. Key tap of Guide push into the device hole. 2. Lock the Guide by turning into arrow direction. Battery Change 1. Remove battery cover into below direction. 2. Put the battery like picture. 1. Clear the lock by turning the Guide with arrow direction. 2. Remove the Guide with arrow direction like the picture.

Change Jelly Puff. 1. 2. 3. 4. 5. Take out Jelly puff first. Put

Change Jelly Puff. 1. 2. 3. 4. 5. Take out Jelly puff first. Put into new Jelly Puff on the latex puff. Push and put locking loop of jelly puff set fitting with the direction. Lock the needle set into the arrow direction. Removal of the jelly puff is vice-versa. Detaching contaminated Puff. Detach contaminated puff out of the plate. Stich new Puff. 1. Prepare refillable puff & both sides sticker. 2. Paste the sticker on the plate fitting in circle hole. 3. Stick the refillable puff on the sticker. 4. Rub & Press by fingers to check.

Warranty on this product is from this written warranty card. For more details, refer

Warranty on this product is from this written warranty card. For more details, refer to the compensation criteria for consumers. This is followed by company policy only on the replaced product. No responsibility of repair, replacement, and refund until the defective product was returned. Original product is only for A/S, but not for the imitation. (Cautious on the imitation) Guidelines on Compensation for Consumer Damage Within warranty After the warranty A/S처리 Type of damage Failure in performance or When a major repair is required within ten days from the date of purchase Product will be replaced Or refund When a major repair on components is required within one month from the date of purchase Product will be replaced When a major repair is required within one month from the exchanged product. Product will be replaced Or refund Impossible to exchange. functions occurring Defect naturally during normal use Repairable Free service Pay for the repair failure arising from the same defect In case that the company lost the product consumer requests to repair. Impossible to repair Refund Up to three mechanical failures resulting from the same defect, at the 3 th Up to various mechanical failures resulting from the same defect, at the 5 th failure arising from the same defect - or Replaced after pay. Product will be replaced Or refund To be refund by calculating depreciation with 10% increase. In case that there are no spare parts in the company within retention (Max: Purchasing Cost) period. To be replaced or Replaced after calculating depreciation In case that there are spare parts, but in case of impossible of repair. -In case of functional break down caused by consumer’s abuse Consumer’s mishandling failure(fall, shock, breakage, hard movement) or damage by improper use. ) -Breakdown or defect by consumer’s fault or on purpose. -Breakdown or defect from repairing or remodeling by consumer or unauthorized service center -Breakdown or defect from using unauthorized spare parts, consumables, options, etc. 2)Others, -In case of defect by natural disaster (fire, immersion in water, earthquake, etc. ) -In case of consumable’s expire. -In case of outside cause. ※ Components and consumables except for the main body are provided by other warranty period. Pay for the repair

Manufacturer & Sales: Mcure. Co. , Ltd. mcure@mcure. co. kr Medical Complex 4 -203,

Manufacturer & Sales: Mcure. Co. , Ltd. mcure@mcure. co. kr Medical Complex 4 -203, Taejang 2 dong 1720 -26, Wonju, Kangwondo, KOREA. Tel: +82 -33 -734 -5970 *Mcure is selling all the consumable & disposable. Spec RPM: 4700/min. Using Time: 4 Hr continuous. Needle Depth: 0. 25 mm Using time: 3 Hr Recharging Time 3 Hr Battery: AAA Alkaline 1. 5 V 2 pcs. Needle Pin: 20 pin Replace Alarm Time: When LED on power button is blinking. Size: Handpiece- 47. 9 mm * 130 mm* 45. 3 mm Puff- 33 mm(Dim) * 27 mm(H) Manufacturing Date: Manufacturing No. :