Power Logic PM 800 series Compact modular meters

  • Slides: 39
Download presentation
Power. Logic PM 800 series Compact, modular meters for feeders and critical loads

Power. Logic PM 800 series Compact, modular meters for feeders and critical loads

A Power. Logic system can help you… ● Improve energy efficiency and lower emissions

A Power. Logic system can help you… ● Improve energy efficiency and lower emissions ● Maximize the use of power distribution networks and reduce per-unit energy costs ● Improve overall power quality, reliability of equipment and processes Schneider Electric - Division - Name – Date 2

Power. Logic PM 800 series meters ● Affordable, compact and modularly flexible meters designed

Power. Logic PM 800 series meters ● Affordable, compact and modularly flexible meters designed for use on feeders and mains ● Install into new equipment or retrofit into existing installations ● Three models satisfy a range of applications Schneider Electric - Division - Name – Date 3

Part of a complete solution PM 800 series meters can be used for standalone

Part of a complete solution PM 800 series meters can be used for standalone panel instrumentation, or as a key component in a complete power monitoring and control solution that provides transparent access to all of your intelligent devices. Schneider Electric - Division - Name – Date Software - Power. Logic ION Enterprise -Power. Logic ION EEM - Power. Logic Power. View Data Communications - EGX 100/EGX 300 - Modems Energy and power quality meters and monitors Energy and power quality meters Other compatible devices Intelligent Devices - All Power. Logic meters - Low voltage breakers - Med voltage relays - Other Modbus devices Other compatible devices 4

Industries and applications Buildings Industry Energy & Infrastructure (includes utilities & critical power) Schneider

Industries and applications Buildings Industry Energy & Infrastructure (includes utilities & critical power) Schneider Electric - Division - Name – Date 5

Industries and applications – Energy savings ● Key applications: ● Energy sub-billing ● Electricity

Industries and applications – Energy savings ● Key applications: ● Energy sub-billing ● Electricity procurement optimization ● Power factor correction ● Peak demand reduction ● Energy cost recovery ● Energy cost allocation (including bill auditing) ● Substation automation (industrial) Schneider Electric - Division - Name – Date 6

Industries and applications Energy availability and reliability ● Key applications: ● Alarming and event

Industries and applications Energy availability and reliability ● Key applications: ● Alarming and event logging Harmonic filtering ● Energy usage analysis ● Energy asset optimization (by building, floor, zone, PDU, or rack) ● Power quality monitoring & reporting Schneider Electric - Division - Name – Date 7

Industries and applications Equipment optimization ● Balance loads plus reduce harmonics and other factors

Industries and applications Equipment optimization ● Balance loads plus reduce harmonics and other factors that cause heating and shorten equipment life ● Maximize existing capacity to avoid unnecessary capital purchases by understanding loading and identifying spare capacity on existing equipment Schneider Electric - Division - Name – Date 8

Summary of Key Features PM 810 with PM 810 Log PM 820 PM 850

Summary of Key Features PM 810 with PM 810 Log PM 820 PM 850 PM 870 Disturbance Detection n Advanced Waveform Capture n EN 50160 Evaluation n n Standard Waveform Capture n n Trending and Forecasting n n Custom Data Logging n n Size (kb) 80 80 800 Custom Logs 1 1 4 4 Billing Log n n Shift Energy Log n n n n 31 st 63 rd Alarm Log Individual Harmonics n Accuracy ANSI 12. 20 Class 0. 2 and IEC 62053 -22 Class 0. 5 S (all models) V, I, Energy, Demand, THD n n n Alarms, RS 485, Option Modules n n n Schneider Electric - Division - Name – Date 9

Recent enhancements ● Real energy accuracy ● ANSI 12. 20 Class 0. 2 compliant

Recent enhancements ● Real energy accuracy ● ANSI 12. 20 Class 0. 2 compliant ● IEC 62053 -22 Class 0. 5 S compliant ● Remote display ● Type 12 compliant with Gasket. The new gasket ships with mounting kit included when you order any remote display models ● When the gasket is not installed, the PM 8 remote display is Type 5 compliant ● Surge withstand compatibility ● IEEE C 37. 90. 1: 2002 compliant ● Surge immunity ● IEC 61000 -4 -12: 2006 compliant ● PM 850 and PM 870 include 4 configurable datalogs ● GPS time synchronization. Available for any input (including built-in digital input S 1) ● Power Quality Evaluation according to EN 50160/ITI(CBEMA) and SEMI F 47 power quality standards ● Input metering or WAGES support ● SNMP support with PM 8 ECC firmware version 2. 2300 Schneider Electric - Division - Name – Date 10

Part of a complete Power. Logic solution ● Integrate with Power. Logic ION Enterprise

Part of a complete Power. Logic solution ● Integrate with Power. Logic ION Enterprise ● Helps engineering and management personnel meet operational goals: ● Improve efficiency and cut energy-related costs ● Assure reliability and reduce downtime ● Optimise equipment utilisation and reduce the cost of operations Schneider Electric - Division - Name – Date 11

Physical Features Schneider Electric - Division - Name – Date 12

Physical Features Schneider Electric - Division - Name – Date 12

Physical features ● Maintenance and alarm icons — view alarm status at the meter

Physical features ● Maintenance and alarm icons — view alarm status at the meter ● Easy-to-read, backlit LCD display ● Anti-glare, scratch resistant ● Displays four values simultaneously; view three phases and neutral ● View summary screens and bar chart displays to see a snapshot of your system ● Intuitive, self-guiding menus are easy to use without training ● Multiple languages — supports English, French, Spanish, German and other* The power meter’s three display options—integral display, no display, or remote display—let you purchase only what you need. * additional languages: Portuguese and Russian. Schneider Electric - Division - Name – Date 13

Physical features (continued) ● KY Out/Digital IN ● Control voltage ● Voltage Inputs —

Physical features (continued) ● KY Out/Digital IN ● Control voltage ● Voltage Inputs — 600 VAC direct connect; eliminates the need for PTs in most cases ● Remote Display/Option Module connector ● Current inputs — rated at 15 A, able to withstand overcurrents from CTs ● RS-485 communications, configurable for 2 wire Modbus-RTU or -ASCII ● Communicate to Power. Logic software ● Integrate into BAS or SCADA systems ● Download firmware updates to keep upto-date with the latest features Schneider Electric - Division - Name – Date 14

Physical features (continued) ● Remote display option: ● Install the meter inside the low

Physical features (continued) ● Remote display option: ● Install the meter inside the low voltage cabinet when local regulations do not permit over 120 V on panel doors ● Can be used to configure meter when a permanent display is not required ● Provides an additional RS 232/485 communications port, configurable for 2 - or 4 -wire support ● Type 2 compliant with gasket Schneider Electric - Division - Name – Date The configurable communications port on the remote display lets you add the power meter to an existing 4 -wire RS-485 daisychain without a converter. 15

Physical features (continued) ● Compact design - 96 x 70 mm (depth inside panel

Physical features (continued) ● Compact design - 96 x 70 mm (depth inside panel with Modbus and 2 I/O) ● Shallow depth saves panel space ● Flush panel mount with a 92 x 92 mm cutout ● International standard design ● Retro-fit existing analog meters with 4” round cutouts — no mounting adapter required ● Din rail mounting w/o display ● Avoid voltage and current wires at panel door Schneider Electric - Division - Name – Date 16

PM 800 series meter Add-on I/O modules Schneider Electric - Division - Name –

PM 800 series meter Add-on I/O modules Schneider Electric - Division - Name – Date 17

Field-installable input & output modules ● Flexible I/O ● Monitor equipment status ● Monitor

Field-installable input & output modules ● Flexible I/O ● Monitor equipment status ● Monitor and enunciate critical alarm status ● Sync with Utility demand intervals ● Monitor other utilities (water, gas, etc. ) ● Standard I/O includes: ● 1 KY Digital output ● 1 Digital input ● Field-installable I/O option modules* ● Digital - 2 inputs and 2 outputs ● Digital - 6 inputs and 2 outputs ● Digital - 2 in and 2 out, Analog - 2 in and 2 out Schneider Electric - Division - Name – Date Two I/O modules can be installed on the back of the power meter. 18

PM 8 ECC PM 800 series Ethernet communications module Schneider Electric - Division -

PM 8 ECC PM 800 series Ethernet communications module Schneider Electric - Division - Name – Date 19

PM 8 ECC Power Status LED indicators for Ethernet communications Bias, Termination, & 2

PM 8 ECC Power Status LED indicators for Ethernet communications Bias, Termination, & 2 -wire / 4 -wire jumper switches LED indicators for serial communications 10/100 Base Tx RS 485 serial port Schneider Electric - Division - Name – Date 20

Features ● Provides direct Ethernet connectivity solution using an existing LAN/WAN network ● Offers

Features ● Provides direct Ethernet connectivity solution using an existing LAN/WAN network ● Offers a high-speed communication connection to increase system performance on alarms and data transfers ● Allows a wider range of connectivity options ● E-mail on alarm notification ● Field installable - no external power supply requirement ● Field downloadable firmware for easy upgrades ● Industrial operating temperature range (-25 to 70 o. C) ● Fully isolated communication ports ● TRE 1 (Transparent Ready Power Equipment – Level 1) compliant ● Advanced security (session based log-on, Modbus. TCP filtering) ● Configurable bias and termination for the RS 485 serial port ● Web browser based Diagnostics and Register Reader ● SNMP support for a private host PM 8 ECC MIB allowing the reading of Basic Metering Data, I/O Configuration and Status, Alarm Configuration and Status, plus SNMP Trap generation in response to any PM 8 on-board alarm. Schneider Electric - Division - Name – Date 21

Technical specifications ● 10/100 Base. Tx Ethernet ● Supported protocols: Modbus. TCP/IP, FTP, SNMP

Technical specifications ● 10/100 Base. Tx Ethernet ● Supported protocols: Modbus. TCP/IP, FTP, SNMP MIB 2, ARP, UDP, and HTTP, SMTP, SNTP ● LED indicators: Link, Tx, Rx, Link speed (10/100 differentiated by color) ● RS 485 serial port ● Baud rates from 2400 to 38. 4 k ● Full optical Isolation ● Serial protocols include: Modbus/RTU, , Power. Logic and Jbus ● Screw terminal connector for RS 485 ● Support for 2 -wire and 4 -wire daisy-chains ● Configurable bias and termination ● LED indicators: Tx, Rx Schneider Electric - Division - Name – Date 22

SNMP support ● Simple Network Management Protocol (SNMP) is a UDP-based network protocol. It

SNMP support ● Simple Network Management Protocol (SNMP) is a UDP-based network protocol. It is used mostly in network management systems to monitor network-attached devices for conditions that warrant administrative attention ● SNMP is typically supported in datacenters and systems that use Uninterruptible Power Supply (UPS). SNMP is the choice protocol for these system. As a result, the administrator of these facilities require information represented in this format. ● SNMP support for the PM 8 ECC (with firmware version 2. 300 or above) includes Traps are notifications sent from the SNMP Agent to the SNMP Manager. We use Traps within the SNMP protocol to send PM 8 Alarm notifications. Schneider Electric - Division - Name – Date 23

Installation Schneider Electric - Division - Name – Date 24

Installation Schneider Electric - Division - Name – Date 24

Designed with the panel builder in mind ● Single person installation ● Mounting resistance

Designed with the panel builder in mind ● Single person installation ● Mounting resistance nibs hold meter until the mounting clips are snapped into place ● No tools required to mount the meter ● Direct connection of Voltage Inputs ● Up to 600 Vac ● Wide range control power supply ● 115 – 415 Vac (15 v. A); 125 – 250 Vdc (10 watts) ● Reduces the number of models to order and stock Schneider Electric - Division - Name – Date 25

Real energy accuracy Schneider Electric - Division - Name – Date 26

Real energy accuracy Schneider Electric - Division - Name – Date 26

Power and accuracy ● One of the most powerful microprocessors in its class ●

Power and accuracy ● One of the most powerful microprocessors in its class ● 128 Samples/Cycle provides high accuracy and harmonic data ● Zero blind metering — no blind spots in data ● Meets ANSI C 12. 20 Class 0. 2 and IEC 62053 -22 Class 0. 5 S for Active Energy (all models) Schneider Electric - Division - Name – Date 27

Advanced features Schneider Electric - Division - Name – Date 28

Advanced features Schneider Electric - Division - Name – Date 28

Customizable alarming ● Factory configured alarms ● Detect circuit overloading before the breaker trips

Customizable alarming ● Factory configured alarms ● Detect circuit overloading before the breaker trips ● Quickly identify the source of a problem ● Create custom alarms (PM 820, PM 850, PM 870) ● Combine up to four alarms using Boolean logic (PM 850 and PM 870) ● Voltage/current disturbance alarms for sag/swell detection (PM 870) The power meter’s alarm summary can help identify persistent alarm conditions that need attention. Alarms, stored in power meter memory and viewed in Power. Logic software, provide early warning of potential problems. Schneider Electric - Division - Name – Date 29

Advanced logging ● Onboard memory for reliable collection of historical data: ● PM 850,

Advanced logging ● Onboard memory for reliable collection of historical data: ● PM 850, PM 870 - 800 k standard ● PM 810 with logging module, PM 820 - 80 k standard ● Factory default logging starts as soon as meter is powered up ● Benefits of onboard data logging: ● Reduce network traffic ● Prevent gaps in data due to network or computer downtime Logged data can be downloaded to Power. Logic software for use in historical reports for capacity planning, energy trending, and more. Schneider Electric - Division - Name – Date 30

Advanced logging (continued) ● On board data logs include: ● Min/Max log—min/max value for

Advanced logging (continued) ● On board data logs include: ● Min/Max log—min/max value for each quantity since last reset ● Custom data logs with up to 96 quantities each (One log – PM 820 and PM 810 with logging module; Three logs – PM 850, PM 870) ● Billing log and Shift Energy table Quantities Logged Minutes Days Months k. Wh IN Each 15 Min for 12 days 32 Days of Daily logs 2 years of monthly logs k. Wh OUT (1152 intervals) (32 intervals) (24 Intervals) k. VARh IN k. VARh Out k. VAh Total The power meter’s billing log can be uploaded and viewed in Power. Logic System Manager software. 52 days of storage for a single register quantity 48 days of a single energy value (4 registers) PF Total k. W Demand k. VAR Demand Notes • Quantities logged are default values and are user-definable. • Daily and monthly PF and demand values represent the last value of the day or month. Schneider Electric - Division - Name – Date 31

Advanced logging (continued) ● Shift energy log tracks energy usage and cost for up

Advanced logging (continued) ● Shift energy log tracks energy usage and cost for up to three, user-definable shifts ● Register-based data is accessible by building automation and SCADA software Schneider Electric - Division - Name – Date 32

Power quality monitoring ● Current and voltage individual harmonic magnitudes and angles to the

Power quality monitoring ● Current and voltage individual harmonic magnitudes and angles to the 31 st harmonic (PM 810 LOG, PM 820), or 63 rd harmonic (PM 850, PM 870) ● Total harmonic resolution to the 63 rd harmonic for RMS values Schneider Electric - Division - Name – Date 33

Power quality monitoring (continued) ● The power meter (PM 850, PM 870) measures power

Power quality monitoring (continued) ● The power meter (PM 850, PM 870) measures power quality according to the EN 50160/ITI(CBEMA) and SEMI F 47 Power Quality standards. ● The EN 50160 standard defines the voltage quality a customer can expect from the utility. The status (pass or fail) of each evaluation category can be viewed in ION- E tables. The power meter generates alarms when an area of evaluation is outside of the range of acceptable values. Schneider Electric - Division - Name – Date 34

Standard waveform capture (PM 850) ● Waveform Capture ● Manual or Alarm initiation ●

Standard waveform capture (PM 850) ● Waveform Capture ● Manual or Alarm initiation ● 128 samples/cycle, 3 cycles ● Waveforms give a graphical representation of what’s happening with your power during a particular moment. ● Quickly isolate potential power problems. ● Excellent for troubleshooting problems that occur continuously. Schneider Electric - Division - Name – Date 35

Disturbance detection and advanced waveform capture (PM 870) ● The PM 870 has the

Disturbance detection and advanced waveform capture (PM 870) ● The PM 870 has the ability to detect, alarm upon, and capture voltage and current sags and swells that can cause unwanted trips and process interruptions, damage motors and more. ● Twelve factory configured voltage disturbance (sag/swell) alarms provide warning and trigger a disturbance waveform capture. ● Disturbance alarms can be reconfigured for current sag and current swell using Power. Logic software. Voltage sags are often caused by heavy loads being started. The PM 870’s disturbance detection features can help isolate the source of troublesome sags and swells. Schneider Electric - Division - Name – Date 36

Disturbance detection and advanced waveform capture (continued) ● Advanced waveform capture (PM 870) provides

Disturbance detection and advanced waveform capture (continued) ● Advanced waveform capture (PM 870) provides a detailed picture of the disturbance event ● Configurable from 185 cycles on one channel at 16 samples/cycle up to 3 cycles on six channels at 128 samples/cycle Schneider Electric - Division - Name – Date Poor power quality can lead to costly downtime. A PM 870’s disturbance waveform capture can provide the information needed to diagnose an event. 37

Trending and forecasting (PM 850, PM 870) ● The power meter maintains onboard trends

Trending and forecasting (PM 850, PM 870) ● The power meter maintains onboard trends with historical values and forecast values to help predict future performance ● Min/Max and Average data available for minutes, hours, days and months ● Forecast for hours and days ● Hourly and weekly summaries ● Trend tables for typical values (e. g. Real Power, Current, Voltage) can be viewed in Power. Logic software The power meter’s onboard trend data with predicted values, can be viewed in Power. Logic software. Schneider Electric - Division - Name – Date ● Since trend data is register-based, it is accessible by building automation and SCADA software 38

For more detailed information on this product, or other products, services and solutions ●

For more detailed information on this product, or other products, services and solutions ● Ask your Schneider Electric representative ● Visit www. schneider-electric. com Schneider Electric - Division - Name – Date 41