	PAVIRO - Introduction Security Systems 1 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as ST-CO/MKA 1. 22 | 13/03/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction PAVIRO – A Public Address and Voice Evacuation System with Professional Sound Quality Flexibility right from the start Security Systems 2 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction PAVIRO In this module we will introduce the PAVIRO - Public Address and Voice Alarm System. Security Systems 3 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Module Objectives After completing this module, you will be able to: Give an overview of the PAVIRO system components Understand the signal flow between the system components Understand different topologies Setup a basic system Understand the use of the available system configuration software Security Systems 4 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Overview PAVIRO consists of 7 main hardware components. The 4 most important are: PVA-4 CR 12 - PAVIRO controller PVA-4 R 24 - PAVIRO router PVA-2 P 500 - PAVIRO amplifier PVA-15 CST - PAVIRO call station Security Systems 5 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Overview Designing a system starts with a controller, an amplifier and a call station. This is the most basic installation supporting up to 12 zones or up to 6 zones A/B wiring with a maximum 1000 Watt loudspeaker load in total. Security Systems 6 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Overview It can easily be expanded with more call stations, call station extensions, routers and amplifiers. Security Systems 7 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Overview Each router will add 24 zones to the system. A maximum of 20 routers may be connected to 1 system adding up to 480 Zones. Together with the 12 zones of the controller makes a maximum of 492 zones per system. Security Systems 8 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Signal Flow Amplifier In the following schematics we will give you an overview of the audio signal flow between the system components. The audio signal is distributed from the controller to an amplifier. Internal Router Controller From the amplifier to the internal router of the controller. Or to a router. Security Systems 9 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Signal Flow - Controller We will now take a closer look at each component. call stations Starting with the controller where we can see the following external audio inputs: Mic /Line Aux Call stations - 4 inputs Microphone / Line - 2 inputs Auxiliary - 2 inputs Controller Security Systems 10 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Signal Flow - Controller The controller has an internal 2 channel message manager plus 2 Alarm- and 2 chime generators. call stations 1 2 3 4 DSP matrix Mic /Line Audio 4 audio Channels channels Aux Message Manager Alarm 1 Alarm 2 Chime 1 Chime 2 Controller The digital signal processing (DSP) matrix will distribute all audio signals to 4 balanced analog audio channel outputs at line level. These audio channels are used as audio input for the amplifiers. Security Systems 11 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Signal Flow - Amplifier 1 Audio 2 Channels 3 4 Inside the amplifier the 4 audio channels from the controller are distributed by 4 -in-1 routers. Line level Σ CH 1 router 4 -in-1 1 70 V / 100 V There are 2 class D amplifiers of 500 W in each unit. L 1 Σ CH 2 router 4 -in-1 Each amplifier has 2 local inputs which can be used instead of audio input 4. 2 L 2 Amplifier 70 V / 100 V The output of the amplifiers are either 70 V or 100 V. The 70 V and 100 V signals are used as input signal for router clusters. Security Systems 12 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Signal Flow - Controller 70 V / 100 V A 1 A 2 Internal Router 2 -in-6 router Spare Each controller and router has per router cluster of 6 zones, 2 amplifier inputs and 1 spare amplifier input. 1 2 3 4 5 6 Controller Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 In this schematic we connect the 2 outputs of 1 amplifier to amplifier input A (1 and 2) of the controller. The internal 2 -in-6 router cluster will distribute the 2 amplifier input signals to 6 loudspeaker outputs. Security Systems 13 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Signal Flow 1 -in-N Topology – 6 Zones Amplifier call stations 1 DSP matrix Mic /Line 4 Σ CH 1 router 4 -in-1 1 CH 2 router 4 -in-1 2 L 1 Aux Message Manager Alarm 1 Alarm 2 Chime 1 Chime 2 Σ L 2 A 1 2 -in-6 router In this schematic we can see the total signal flow from the controller via the 4 audio channels to the amplifier. The amplified signal (70 - or 100 V) goes back to one of the amplifier inputs of the controller. In this case amplifier input A 1. Controller Security Systems 14 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Signal Flow 1 -in-N Topology – 6 Zones Amplifier call stations 1 DSP matrix Mic /Line Σ 4 CH 1 router 4 -in-1 1 CH 2 router 4 -in-1 2 L 1 Aux Message Manager Alarm 1 Alarm 2 Chime 1 Chime 2 Σ L 2 A 1 1 2 2 -in-6 router 3 4 5 6 Controller Zone 1 Zone 2 The internal 2 -in-6 router cluster of the controller distributes the amplifier input signal A 1 to 6 loudspeaker outputs with a maximum loudspeaker load of 500 Watt in total. This is what we call a 1 -in-N topology. Zone 3 Zone 4 Zone 5 Zone 6 Note: when a call is made to one zone there will be no audio in the other zones. This means that when e. g. music was playing it will be lost. Security Systems 15 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Signal Flow 1 -in-N Topology – 12 Zones Amplifier call stations 1 DSP matrix Mic /Line Σ 4 CH 1 router 4 -in-1 1 CH 2 router 4 -in-1 2 L 1 Aux Message Manager Alarm 1 Alarm 2 Chime 1 Chime 2 Σ L 2 A 1 1 2 -in-6 router 2 6 3 2 -in-6 router 4 7 5 6 12 Zone 1 Zone 2 Zone 6 B 2 Zone 3 Zone 4 Zone 5 Zone 7 Zone 6 Zone 12 The controller has 2 internal 2 -in-6 router clusters (A and B) each with 6 loudspeaker outputs. By connecting the amplifier also to amplifier input B of the controller the total amount of loudspeaker outputs will be 12 with a maximum loudspeaker load of 1000 Watt in total. Controller Security Systems 16 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Signal Flow Call / Program Topology – 6 Zones Amplifier call stations 1 DSP matrix Mic /Line Σ 4 CH 1 router 4 -in-1 1 CH 2 router 4 -in-1 2 L 1 Aux Message Manager Alarm 1 Alarm 2 Chime 1 Chime 2 Σ L 2 A 1 1 2 -in-6 router 6 7 12 Controller Zone 1 Zone 6 Zone 7 Zone 12 By connecting an amplifier to both amplifier inputs of one 2 -in-N router cluster a Call / Program topology can be created. In this example we connect the amplifier outputs to amplifier input A 1 and A 2 of the controller. The total amount of loudspeaker outputs will be 6 with a maximum loudspeaker load of 500 Watt in total. Security Systems 17 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Signal Flow Call / Program Topology – 6 Zones Amplifier call stations 1 DSP matrix Mic /Line Σ 4 CH 1 router 4 -in-1 1 CH 2 router 4 -in-1 2 L 1 Aux Message Manager Alarm 1 Alarm 2 Chime 1 Chime 2 Σ L 2 A 1 1 2 -in-6 router 6 7 12 Zone 1 Zone 6 Zone 7 Zone 12 In a Call / Program topology it is possible to make a call to one zone while audio is still present in the other zones. This means that when e. g. music was playing it will not be lost. More system topologies are explained in the PAVIRO L 2 web based training. Controller Security Systems 18 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Components - Controller We will now take a closer look at each system component individually. The heart of the system is the controller PVA-4 CR 12. It includes DSP and distributes 4 audio channels simultaneously. The controller has an internal router which allows you to connect up to 12 zones. Security Systems 19 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Components - Amplifier A basic system consists of a controller, an amplifier and a call station. There is 1 amplifier model available, PVA-2 P 500. This is a 2 x 500 W class-D amplifier. The output of the amplifier is either 70 V or 100 V. Security Systems 20 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Components - Routers are available for larger systems with more than 12 zones. The router PVA-4 R 24 is a device which supports 24 loudspeaker zones. It is structured into four 2 -in-6 relay clusters. Maximum 20 routers (480 zones) Maximum of 492 zones in total Security Systems 21 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Components – Call Station The system allows up to 16 call stations PVA-15 CST to be connected to a single PAVIRO controller Security Systems 22 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Components – Call Station Extension Up to 5 call station extensions PVA-20 CSE can be connected to each call station. Security Systems 23 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Components – Call Station Kit The PVA-CSK call station kit allows you to create your own customized call station. Security Systems 24 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Components – End Of Line Supervision Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 1 2 It is possible to supervise the loudspeaker lines in 2 ways: 1. impedance measurement 2. End Of Line supervision (EOL) For EOL supervision there are 2 options: • 1 PLN-1 EOL board 2 PVA-1 WEOL board 1. Security Systems 25 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Components – End Of Line Supervision First option is the PLN-1 EOL board as shown here. Note that from the output of this EOL board 2 wires have to be connected to a PVA‑ 4 CR 12 controller- or PVA‑ 4 R 24 router control input. For more details about EOL supervision please check the Loudspeaker Line Supervision training module. Security Systems 26 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Components – End Of Line Supervision The second option is the PVA-1 WEOL board. Note that this board requires a ground connection. The PVA-1 WEOL completes the family of products. Security Systems 27 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Easy System Setup Controller 1 7 4 2 5 3 6 Amplifier 1 To illustrate an easy system setup we show you how to connect an amplifier to a controller step by step: 2 4 5 • 1 • 2 • 3 • 4 • 5 • 6 • 7 Power connections CAN BUS Ethernet (PC connection) 4 audio channels Amplifier (100 V / 70 V) Loudspeakers Call Station Security Systems 28 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Configuration Configuring a system is easily done with the PAVIRO Configuration Wizard configuration software. The wizard guides you through the system setup step by step. This can be done off line on a PC without any connection to the PAVIRO system. Once the configuration is ready it can be saved as an “IRIS-Net Project File”. Security Systems 29 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Configuration Controller The project file can be opened by the IRIS-Net graphical user interface software. Connecting the controller via the Ethernet interface allows the controller to communicate with a PC. Once connected, the configuration can be uploaded via the IRIS-Net software. IRIS-Net not only allows easy configuration, but it also allows you to operate and monitor the entire system. Security Systems 30 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Configuration Advanced configuration of the whole system is done by IRIS-Net PC software. It also enables the overall configuration of the controller to be performed off-line using a PC (i. e. without establishing a connection between the PC and controller). Security Systems 31 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Configuration The configuration can then be transferred by establishing a connection between the PC and controller via Ethernet. Security Systems 32 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction System Configuration In addition to configurations, IRIS-Net can also be used for comprehensive checking and monitoring of a system. For more details on using IRIS-Net please check the corresponding training module. Security Systems 33 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Summary To summarize, there are 7 main hardware products available in the PAVIRO product family: PVA-4 CR 12 - PAVIRO controller PVA-4 R 24 - PAVIRO router PVA-2 P 500 Security Systems 34 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. - PAVIRO amplifier
 
	PAVIRO - Introduction Summary PVA-15 CST - PAVIRO call station PVA-20 CSE - PAVIRO call station extension PVA-CSK - PAVIRO call station Kit PVA-1 WEOL - PAVIRO Wireless End Of Line board Security Systems 35 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Summary System size Basic system: 1 controller 1 amplifier 1 call station Up to 12 zones Security Systems 36 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Summary System size Large system: 1 controller Up to 20 routers Up to 50 amplifiers Up to 16 call stations Up to 5 call station extensions per call station Up to 492 zones Security Systems 37 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Summary Zone 1 Loudspeaker line supervision: Zone 2 impedance measurement End Of Line supervision (EOL) Zone 3 Zone 4 Zone 5 Zone 6 EOL supervision: • 1 • 2 1 PLN-1 EOL board PVA-1 WEOL board 2 Security Systems 38 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Summary Easy configuration with the PAVIRO Configuration Wizard. IRIS-Net: Required for system configuration Optional for system operation and monitoring Security Systems 39 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Summary You have now reached the end of the introduction to the PAVIRO – Public Address and Voice Alarm System. You should now be able to: Give an overview of the PAVIRO system components Understand the signal flow between the system components Understand different topologies Setup a basic system Understand the use of the available system configuration software Security Systems 40 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction Module Test Once you have passed the following test, you can continue with the next training module. Learnt Knowledge Module Test Information about the test: Multiple choice test with 10 questions More than 1 answer can be correct You have to achieve at least 80% to pass the test Good luck! Security Systems 41 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
 
	PAVIRO - Introduction PAVIRO Congratulations! You have now successfully completed the training module “PAVIRO – Introduction“. If you want to learn more about the PAVIRO system please check the following training modules: PAVIRO – Controller PVA-4 CR 12 PAVIRO – Amplifier PVA-2 P 500 PAVIRO – Router PVA-4 R 24 PAVIRO – Call Station PVA-15 CST PAVIRO – Loudspeaker Line Supervision Security Systems 42 ST-CO/MKA 1. 22 | 06/07/2015 | © Robert Bosch Gmb. H 2015. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.