Particle therapy masterclass THERAPY PLAN IN G FOR

  • Slides: 9
Download presentation
Particle therapy masterclass THERAPY PLAN IN G FOR LIVER AND HEAD_AND_NECK SA INT PETER

Particle therapy masterclass THERAPY PLAN IN G FOR LIVER AND HEAD_AND_NECK SA INT PETER SBUR G STATE UNIVERS ITY KAR INA K ORABELSHCHIKOVA & IVAN KA ZARIN ON BEHALF OF 13 PERSONS

TABLE OF CONTENT • ABSTRACT • C PHANTOM • LIVER • HEAD_AND_NECK • CONCLUSION

TABLE OF CONTENT • ABSTRACT • C PHANTOM • LIVER • HEAD_AND_NECK • CONCLUSION

ABSTRACT 1) possibility of destroying tumors with different particles (photons, protons and carbon ions)

ABSTRACT 1) possibility of destroying tumors with different particles (photons, protons and carbon ions) was tested for the Cphantom, liver and head_and_neck cases 2) the shape of tumors was studied and the optimal angles were selected with the account of the patient’s geometry 3) the absorbed dose in tumors and organs at risk was compared for different types of beam particles 4) the best result was obtained for protons and carbon ions

C PHANTOM - GAMMA C phantom is composed of the C-shaped target and cylindrical

C PHANTOM - GAMMA C phantom is composed of the C-shaped target and cylindrical core (organ at risk) The first choice of radiation type was photons It left us with the unsatisfactory results Here paste your C phantom CT scan with all beams that are applied

C PHANTOM - PROTONS The second choice of radiation type was protons Effect on

C PHANTOM - PROTONS The second choice of radiation type was protons Effect on the C-shape is similar to the gamma case Minimum dose on body and core was found

COMPARISON FOR PHOTON AND PROTON THERAPY FOR LIVER PHOTON THERAPY PROTON THERAPY CARBON THERAPY

COMPARISON FOR PHOTON AND PROTON THERAPY FOR LIVER PHOTON THERAPY PROTON THERAPY CARBON THERAPY 5 beams configuration for protons and carbons are much better than 5 beams of photons Carbon ions provide less irradiation before the target but leave some traces in the area behind the target

PROTON THERAPY FOR HEAD_AND_NECK 1) We were trying to find the optimal angle to

PROTON THERAPY FOR HEAD_AND_NECK 1) We were trying to find the optimal angle to minimize irradiation of the Paratoids 2) Single field of protons with the 180 degrees direction provides us with the reasonably good results

CONCLUSION The best result was obtained for protons and carbon ions

CONCLUSION The best result was obtained for protons and carbon ions

Thank you for your attention! Спасибо!

Thank you for your attention! Спасибо!