PANFOCAL Visual Acuity A Practical Measure of Functional

  • Slides: 12
Download presentation
PAN-FOCAL Visual Acuity A Practical Measure of Functional Vision Milind Pande Andrew Bourne Emily

PAN-FOCAL Visual Acuity A Practical Measure of Functional Vision Milind Pande Andrew Bourne Emily Proudfoot Neha Vijh Vision Surgery & Research Centre East Yorkshire, United Kingdom Authors have no financial interest in the subject matter of this poster

Presbyopia IOL Mismatch • Patients: Can I – Drive – Use Desktop, Laptop, I

Presbyopia IOL Mismatch • Patients: Can I – Drive – Use Desktop, Laptop, I phone – Read books, newspapers, magazines, telephone directories – Read in bed etc. . • We measure – Photopic Distance, Near, rarely Intermediate UCVA • Inadequate data to answer patient questions • Mismatch of patient expectations and Presbyopia IOL performance leads to unhappy patients despite good UCVA

Current Measures of Functional Vision in Presbyopia IOLs • VA across the full focal

Current Measures of Functional Vision in Presbyopia IOLs • VA across the full focal range: Photopic and Mesopic Defocus Curves • Photopic and Mesopic Contrast sensitivity at distance, inter and near • Time Hungry and Cumbersome • Totally Impractical in Clinical settings ®

PAN-FOCAL VA • Developed as a practical clinical measure of VA across distances and

PAN-FOCAL VA • Developed as a practical clinical measure of VA across distances and illumination levels. • Consists of Binocular Snellens UCVA for – Photopic (330 Lux) Distance – Photopic (330 Lux) Intermediate @ 65 cm – Photopic (330 Lux) and Mesopic (100 Lux) Near @ 33 cm

PANFOCAL VA: VALIDATION METHODS • 16 patients, > 6 weeks post-op • • Multifocal

PANFOCAL VA: VALIDATION METHODS • 16 patients, > 6 weeks post-op • • Multifocal M&M 5 Bilateral same Multifocal 2 Accommodative 5 Monovision 4 • PANFOCAL VA measured • Patient Questionnaire • Objective Task Performance

OBJECTIVE ASSESSMENT INTERMEDIATE TASK PERFORMANCE DESKTOP & LAPTOP COMPUTING

OBJECTIVE ASSESSMENT INTERMEDIATE TASK PERFORMANCE DESKTOP & LAPTOP COMPUTING

OBJECTIVE ASSESSMENT NEAR TASK PERFORMANCE PHOTOPIC & MESOPIC Photopic: 330 Lux Mesopic: 100 Lux

OBJECTIVE ASSESSMENT NEAR TASK PERFORMANCE PHOTOPIC & MESOPIC Photopic: 330 Lux Mesopic: 100 Lux

PANFOCAL VA: Methods • Patients grouped by YES/NO responses to Questionnaire and Objective tasks

PANFOCAL VA: Methods • Patients grouped by YES/NO responses to Questionnaire and Objective tasks performance. • VA thresholds analysed in YES/NO groups using Fishers Exact Test • This gave us VA thresholds for each objective task and subjective questionnaire <= 12 NS: 0. 87 <= 9 NS: 0. 02

PANFOCAL VA: RESULTS

PANFOCAL VA: RESULTS

PANFOCAL VA: RESULTS • A single measure of Functional VA derived from PANFOCAL VA:

PANFOCAL VA: RESULTS • A single measure of Functional VA derived from PANFOCAL VA: Mean PANFOCAL VA • Tested in groups with and without total spectacle freedom and objective task performance <=9 0. 03 <=9 0. 007

CONCLUSIONS • PANFOCAL VA <=6/9 is consistent with complete spectacle freedom • PANFOCAL VA

CONCLUSIONS • PANFOCAL VA <=6/9 is consistent with complete spectacle freedom • PANFOCAL VA <=6/9 is consistent with successfully performing tasks like computing on desktop, laptop; reading newspapers, novels, magazines and telephone directories in mesopic and photopic conditions • Mean PANFOCAL VA of <=6/9 is consistent with spectacle freedom as well as all objective task performance Good measure of Functional Vision • PANFOCAL VA is an excellent practical clinical measure of visual function

All Presbyopia IOLs should have PANFOCAL VA measurements to help match IOLs to individual

All Presbyopia IOLs should have PANFOCAL VA measurements to help match IOLs to individual patient needs PANFOCAL VA is a tool to get 20/HAPPY PATIENTS