PACKAGED AIR COOLED FREE COOLING CHILLER New YSFC

  • Slides: 50
Download presentation
PACKAGED AIR COOLED FREE COOLING CHILLER New YSFC 200 - 1700 k. W 14

PACKAGED AIR COOLED FREE COOLING CHILLER New YSFC 200 - 1700 k. W 14 Models York Screw Free Cooling APPLIED CHILLER PRODUCTS

Packaged Air Cooled Free Cooling APPLIED CHILLER PRODUCTS Market Introduction

Packaged Air Cooled Free Cooling APPLIED CHILLER PRODUCTS Market Introduction

What is a Free Cooling? Free Cooling has become an established technology recognised throughout

What is a Free Cooling? Free Cooling has become an established technology recognised throughout Eastern and Northern Europe by End Users, Architects & Building Services Engineers. Reducing Global Energy Consumption and CO 2 emissions is a Clients key driver for his Buildings & Cooling Processes, reducing operating costs and environmental impact. Free Cooling Chiller offers a sustainable alternative, to reduce electrical energy consumption during “winter” ambient periods. The Free Cooling concept switches off compressors when operating conditions allow, to utilise Natural Cooling provided from Low Ambient Air passing across a finned coil containing the process liquid. Client’s consider this as an attractive solution. Ideal applications benefit from having a high 24/7 base load and operate with elevated system return liquid temperatures typically above 15ºC and where the ambient is predicted to be below 5ºC many operating hours each year. APPLIED CHILLER PRODUCTS

Market Requirements For Free Cooling Chiller’s. Our survey revealed this technology is increasing in

Market Requirements For Free Cooling Chiller’s. Our survey revealed this technology is increasing in demand by many users. Although a niche Air Cooled Chiller variant, specifications for such products in most European regions is rapidly increasing and the JCI Sales Teams request the ability to support this technology alternative with their Clients. There a number of various applications in which our traditional Clients are currently specifying and Installing such products: Locations, Long Cold Winters, Northern Latitudes or Eastern Europe, High Altitude. 24/7 Chiller Operating Applications Data Centres, Switch Rooms and Industrial Processes. Chilled Beam and Medium Temperature Air Conditioning. Theatres, Cinemas and Night-Clubs. Hospital Operating Theatres. As Free Cooling is seen as a progressive “Green” product solution. APPLIED CHILLER PRODUCTS

Sales Forecasts & Market Assessment • The Free Cooling project investigated the potential for

Sales Forecasts & Market Assessment • The Free Cooling project investigated the potential for JCI Systems to offer Packaged Air Cooled Free Cooling Chillers, following requests originating mainly from Central and Eastern Europe. • Initial forecast reviews for 2008 indicated a likely requirement for 40 units. • 2010 Product AOP review • Following PS&S review of the European market indicates there is a wide range of clients applying the principals of Free Cooling to their processes. We have concluded that there is a legitimate market for this product variation as the vast majority of Chiller manufactures offer such products. Unfortunately there are no official statistics to support sales volumes to this market. However have seen many enquires for multiple units. (One project for 18 x 750 kw units which we are specified. ) • It is Product Managements assessment that this market has the ability (in normal market conditions) to generate higher volumes than indicated and we believe we have identified a product to meet this demand. APPLIED CHILLER PRODUCTS (April 09) revised this forecast downward to 26 units

Alternative Approaches To Free Cooling Chillers? There are 4 design variations for Free Cooling

Alternative Approaches To Free Cooling Chillers? There are 4 design variations for Free Cooling Systems applied packaged Air Cooled Chillers available in Europe’s market. to 1) Stand Alone Dry Air Cooler. Technically the best solution. Most efficient and flexible option, high installation costs. JCI current solution. 2) Built-in separate Dry Air Cooler. Exclusive applications. Good efficiency levels and often with very high levels of specification, but greater foot print and high cost. 3) Thermosyphen system. Carrier’s Approach. 4) Utilises refrigerant circuitry, has low capital cost and low efficiency. 5) Only two modes of operation restricting mid season application. 4) Dual Function - Free Cooling and Condenser Coil. Commercial. 5) Compact Price competitive solution preferred by European MAC team as a product gap filler. 6) JCI new YSFC solution. APPLIED CHILLER PRODUCTS

Why JCI chose to use an OEM Supplier? Review of the alternative design concepts

Why JCI chose to use an OEM Supplier? Review of the alternative design concepts determined this technology could not be simply applied to our current Product range. The stand alone dry air cooler is the most obvious Energy efficient solution. JCI has been successful in winning such projects. Many Clients now requesting packaged units to reduce installation costs and space. The built-in Dry Air Cooler & Thermosyphen systems both require major equipment redesign. The Dual Function coil block requires less modification to the existing product’s. Adding the additional coils into the current condenser design the unit’s width would Increase, prohibiting JCI from loading units into containers for Global shipment’s. APPLIED CHILLER PRODUCTS

JCI Selected OEM Supplier Following an extensive Market Review we identify the alternative market

JCI Selected OEM Supplier Following an extensive Market Review we identify the alternative market suppliers and product solutions. We finalised an OEM agreement with an Italian producer specialising in the process cooling market for a Unique Branded JCI Design Dual Function - Free Cooling / Condenser Coil A reciprocal agreement exists that if either JCI or Hitema’s existing distributors has a product specified the other party should not chase down the order. No other Hitema product may be ordered from them without Product Management Authorisation APPLIED CHILLER PRODUCTS

Packaged Air Cooled Free Cooling APPLIED CHILLER PRODUCTS Application

Packaged Air Cooled Free Cooling APPLIED CHILLER PRODUCTS Application

Product Selection and Application The YSFC is not seen as a replacement for the

Product Selection and Application The YSFC is not seen as a replacement for the YCIV. Both models have their unique benefits for the client. You select which one is best. YCIV • High Summer efficiency 3. 2 EER. • High 4 ESEER mid season performance. • Continuous VSD Cooling for extended low ambient efficiencies throughout the year. APPLIED CHILLER PRODUCTS YSFC • Lower Summer efficiency EER 2. 6 • 3. 7 ESEER performance • 100% Free Cooling EER 26 At an ambient approximately 16 C below the return chilled liquid temperature there is no Mechanical Cooling required.

Free Cooling Chiller Operating Modes Free Cooling units operate in 3 modes. • Mechanical

Free Cooling Chiller Operating Modes Free Cooling units operate in 3 modes. • Mechanical Cooling Chiller operates in refrigerating mode in summer ambient conditions. • Partial Free & Mechanical Cooling (excluding Thermosyphen system) Where Free Cooling works in series (up-stream) of Mechanical Cooling to reduce compressor load when lower ambient temperatures allow. • Total Free Cooling (Condenser fans running) When the ambient air is cool enough to reject the full heat load from the system. APPLIED CHILLER PRODUCTS

YSFC Free Cooling Chiller Operation During Summer Ambients the unit operates as a typical

YSFC Free Cooling Chiller Operation During Summer Ambients the unit operates as a typical chiller, albeit at a reduced efficiency level. This is due to the additional coil rows required for the Free Cooling circuit placed in front of the condenser. As the ambient falls 6°C below the return system liquid temperature. • The 3 -way valve redirects the flow through to the Free Cooling Coil in series with the evaporator enabling the partial Free Cooling / Mechanical Refrigeration mode. • To maximise unit efficiency each circuit is unloaded and disabled in sequence as the ambient falls. • Whilst a refrigerant circuit is operating the fans continue to maintain the minimum condensing pressure. • As each refrigerant circuit stops, fan control changes to maintain leaving liquid temperature. Winter Ambients, where full free cooling is achieved (without mechanical cooling) the leaving chilled liquid temperature is maintained at the desired temperature by fan control. APPLIED CHILLER PRODUCTS

YSFC Product Schematic Standard Mechanical Chiller Compressor Flow Temp Stat Evaporator EEV Controller Ambient

YSFC Product Schematic Standard Mechanical Chiller Compressor Flow Temp Stat Evaporator EEV Controller Ambient Stat APPLIED CHILLER PRODUCTS Fans Condenser

YSFC Product Schematic Free Cooling Chiller in Mechanical Cooling Mode Compressor Flow Temp Stat

YSFC Product Schematic Free Cooling Chiller in Mechanical Cooling Mode Compressor Flow Temp Stat Evaporator Free Cooling Valve Inlet Temp Stat EEV p. C 03 Controller Ambient Stat Fans Condenser Free Cooling APPLIED CHILLER PRODUCTS When Ambient is Grater than 6°C below the Return Liquid Temperature

YSFC Product Schematic Partial Free & Mechanical Cooling Compressor Flow Temp Stat Evaporator Free

YSFC Product Schematic Partial Free & Mechanical Cooling Compressor Flow Temp Stat Evaporator Free Cooling Valve Inlet Temp Stat EEV p. C 03 Controller Ambient Stat Fans Condenser Free Cooling APPLIED CHILLER PRODUCTS When Ambient is 6°C below the Return Liquid Temperature

YSFC Product Schematic Partial Free & Mechanical Cooling Compressor Flow Temp Stat Evaporator Free

YSFC Product Schematic Partial Free & Mechanical Cooling Compressor Flow Temp Stat Evaporator Free Cooling Valve Inlet Temp Stat p. C 03 Controller Ambient Stat Free Cooling Fans Condenser Free Cooling Condenser APPLIED CHILLER PRODUCTS Condenser Coil Block Profile EEV

YSFC Product Schematic Free Cooling Mode Compressor Flow Temp Stat Evaporator Free Cooling Valve

YSFC Product Schematic Free Cooling Mode Compressor Flow Temp Stat Evaporator Free Cooling Valve Inlet Temp Stat EEV p. C 03 Controller Ambient Stat Free Cooling Fans Condenser Free Cooling Condenser APPLIED CHILLER PRODUCTS When Ambient is low enough to satisfy system cooling demand

YSFC Free Cooling m. W Hours operation Data based on YSFC 850 SB 860

YSFC Free Cooling m. W Hours operation Data based on YSFC 850 SB 860 k. W. Constant load 365 Day 24/7. 24 hr Average Daily Temperature. 15 – 7 Chilled Glycol split. Partial Free Cooling enabled @ 9°C Ambient (6°C below EWT. ). Full Free Cooling -2°C Ambient. This graph shows the potential to save energy as a % comparing the YFSC modes either operating thought the year in Mechanical Cooling or Partial / Total Free Cooling. APPLIED CHILLER PRODUCTS

EER Comparison JCI Chillers Based upon 100% Cooling load (850 k. W) and 5°C

EER Comparison JCI Chillers Based upon 100% Cooling load (850 k. W) and 5°C ambient steps APPLIED CHILLER PRODUCTS

Packaged Air Cooled Free Cooling APPLIED CHILLER PRODUCTS YSFC The Product

Packaged Air Cooled Free Cooling APPLIED CHILLER PRODUCTS YSFC The Product

Introducing the new YSFC Range Two circuit models e d ui o f In

Introducing the new YSFC Range Two circuit models e d ui o f In n O P ly s a le APPLIED CHILLER PRODUCTS R e G. g n E o t r e ef

Introducing the new YSFC Range 2 & 4 circuit models e d ui o

Introducing the new YSFC Range 2 & 4 circuit models e d ui o f In n O P ly s a le APPLIED CHILLER PRODUCTS R e G. g n E o t r e ef

YSFC Standard Features • R 407 c standard options exist via SQ for R

YSFC Standard Features • R 407 c standard options exist via SQ for R 134 a. • • Light grey RAL 7035 polyester epoxy powder paint. • • Two or four fixed speed step control part wind Hermitic Screw Compressor(s) optional Open or Closed transition Star Delta Starters. Carel microprocessor controller including specific Free Cooling software. Electronic Expansion Valves (increased performance in partial mechanical / free cooling mode). • Axial speed controlled condenser fans various options for differing control and drive(s). • Aluminium Fin & Copper Tube Condenser / Free Cooling Ambient Coil’s options for alternative materials / coatings. Shell & Tube Direct Expansion Evaporator 19 mm closed cell insulation. PN 16 inlet manifold and outlet evap. stub for Chilled Liquid flange connections. 6 Bar Three Way Free Cooling Mixing Valve, Heater and Auto Daily Rotation. EPDM Flexible reinforced helix wire compound rubber Hydraulic Tubes. • • APPLIED CHILLER PRODUCTS

YSFC Component Selection When the Clients design characteristics are finalised component selection is then

YSFC Component Selection When the Clients design characteristics are finalised component selection is then Optimised for the specific project design. Design Cooling Capacity Condensing Requirement & Free Cooling load Condensing duty & Sound performance APPLIED CHILLER PRODUCTS We use simulator software, to confirm the dimensions compressor’s of evaporator condenser coil and fans

YSFC Unit Construction - Mount Components After selecting the components a study final of

YSFC Unit Construction - Mount Components After selecting the components a study final of the optimum layout for the base. 3 WAY VALVE TANK (Option) EVAPORATOR COMPRESSORS SUPPLEMENTARY PANEL (Option) APPLIED CHILLER PRODUCTS HYDRAULIC PIPING (Manifold) Inlet Outlet PUMP (Option)

YSFC Unit Construction - The Condenser Module Coils and Fans are selected initially from

YSFC Unit Construction - The Condenser Module Coils and Fans are selected initially from the standard unit design configuration. Cost Performance and Sound Optimisation. JCI Offer Special Quotation variations on Coil lengths, Coil Rows, Fin Pitch, and Fan Performance to meet Project requirements. APPLIED CHILLER PRODUCTS

YSFC Unit Construction - Final Assembly Condenser module With the mechanical component location finalised,

YSFC Unit Construction - Final Assembly Condenser module With the mechanical component location finalised, the Control panel is positioned Control Panel Base The 3 D module is complete and the 2 D drawings are produced automatically for production. APPLIED CHILLER PRODUCTS

YSFC Product, Wiring, Pressure / Instrument Drawings are issued for Client Approval before production

YSFC Product, Wiring, Pressure / Instrument Drawings are issued for Client Approval before production release and lead time conformation. APPLIED CHILLER PRODUCTS

Components Around the YSFC Optional Pump’s and Acoustic Compressor Enclosure Dual relief (option) 3

Components Around the YSFC Optional Pump’s and Acoustic Compressor Enclosure Dual relief (option) 3 Way Valve and Hydraulic pipe connections from manifold to Free Cooling Coils APPLIED CHILLER PRODUCTS

Components Around the YSFC APPLIED CHILLER PRODUCTS

Components Around the YSFC APPLIED CHILLER PRODUCTS

YSFC Product Options and Accessories. Enhanced Free Cooling Performance. The Base unit configuration of

YSFC Product Options and Accessories. Enhanced Free Cooling Performance. The Base unit configuration of unit size and performance has been selected to offer a competitive all round package. For specific applications where the Designer’s requirement is to the potential Free Cooling Performance, the factory can alternatives through the Special Quotation procedure. increase offer Potential variations include: • Reduced Fin Pitch (additional Fins to the Coils). • Increased Air Flow Fans. • Extended Coil length with additional Fans. Building Chilled Liquid Glycol Free option available as SQ Option (Limiting the Glycol circulation loop within the unit). Ideal for use in moderate climates where the ambient falls below zero for only a small number of hours a year. APPLIED CHILLER PRODUCTS

YSFC Product Options and Accessories. 1. 01 1. 02 SQ 1. 03 1. 04

YSFC Product Options and Accessories. 1. 01 1. 02 SQ 1. 03 1. 04 1. 05 1. 06 2. - 2. 06 2. 14 -15 2. 16 3. 01 3. 02 4. 01 -4. 09 4. 02 4. 03 4. 04 4. 05 4. 06 -7 -8 Std SQ Low Noise (Compressor Enclosure). Super Low Noise (Compressor boxes and reduced sound fans). Extend coils + extra modifications to achieve minimal possible sound. Unit Wire Enclosure (Lower Section). Epoxy Coated Ambient Coil. Rubber type anti-vibration mounts. Spring Anti-vibration mounts. Hydronic pump options (see next slides) Pressure Regulation Valve (between 3 -way-valve and Evaporator). Double evaporator insulation 38 mm – Evaporator heater mat. Y mechanical water filter (supplied lose) Compressor Suction Valves. Dual relief change over valves. Star Delta compressor motor starters (Open & Closed Transition) Compressor remote run monitoring contactors Compressor rephasing Main – Auxiliary Panel Heaters for ≤-10°C ambient. Individual fan fuses. Serial card BACNET MODBUS (RS 485) or Echelon. Carrel controller languages, English, French, German, Italian, Spanish. Glycol Free Process System. APPLIED CHILLER PRODUCTS

YSFC Product Hydraulic Pump Options. Single pump 2. 5 bar head option with internal

YSFC Product Hydraulic Pump Options. Single pump 2. 5 bar head option with internal wiring to panel mounted contactors Optional Acoustic boxes for Either Compressors and or Pumps for Low noise versions. Dual pump 2. 5 bar head option with internal wiring to panel mounted contactors Additional Dual Pump Electronic Management Controls. APPLIED CHILLER PRODUCTS

YSFC Product Hydraulic Pump Options. Dual VSD pump option with internal wiring to a

YSFC Product Hydraulic Pump Options. Dual VSD pump option with internal wiring to a panel mounted Single Inverter. With electronic pump Management Controls. Storage Weir Tank. Various additional options Dependant on requirement. Internal constant speed circulation Pump. Optional Acoustic boxes available for Compressor’s and or Pumps, Low noise version. APPLIED CHILLER PRODUCTS

YSFC End-of-line functional run test After assembly the chiller is run tested at prevailing

YSFC End-of-line functional run test After assembly the chiller is run tested at prevailing ambient conditions to verify the Mechanical cooling operation and Safety sequences. (Larger capacity units tests are performed separately on individual circuits. ) Controlled ambient testing is not available at the Factory. APPLIED CHILLER PRODUCTS

YSFC Recorded Test Data AIR FLOW WATER FLOW APPLIED CHILLER PRODUCTS AIR FLOW ELECTRICAL

YSFC Recorded Test Data AIR FLOW WATER FLOW APPLIED CHILLER PRODUCTS AIR FLOW ELECTRICAL POWER

YSFC System Hydraulic Calculations Caution when calculating the chilled liquid pressure drop. In mechanical

YSFC System Hydraulic Calculations Caution when calculating the chilled liquid pressure drop. In mechanical cooling mode the total pressure drop calculation is the 3 way valve and interconnecting Hydraulic pipes + Evaporator. In partial or total Free Cooling modes the pressure drop calculation is the 3 way valve, distribution header, interconnecting hydraulic pipes + Free Cooling Coil + Evaporator. There is obviously a difference in system resistance between the two modes. Discuss this with the client and introduce the option of a pressure regulating valve to equalise the system pressure drop for each mode. This is installed in the Hydraulic pipe between the 3 -way-valve and Evaporator. System Working Pressure. Due to the limitation of the three way valve and Hydraulic pipes the chilled liquid static system pressure is limited to 6 Bar. APPLIED CHILLER PRODUCTS

YSFC Documentation and selection process. The engineering guide allows for manual selection for both

YSFC Documentation and selection process. The engineering guide allows for manual selection for both the Mechanical and Free Cooling Modes. As the free cooling chiller application is more suited to specific regions we plan not translate Documents unit specific requests are received. A selection program is in development and will be distributed Q 4 2009. In the interim period please submit SQ for electronic selections. We will have to pay the software house an operator licence of € 80 for each user. Please email R Smeed to confirm your licence requirement. Pricing is a manual operation using the Master List Price, That will be included in the intranet price pages, with the Multiplier distributed to the Sales Managers as usual. The OEM supplier is happy to work on special applications and options. Please submit a detailed SQ request for review & potential quote. APPLIED CHILLER PRODUCTS

YSFC Intranet information 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.

YSFC Intranet information 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. APPLIED CHILLER PRODUCTS Single Page Product Information Sheet. Engineering Guide. Installation Commissioning Operation and Maintenance Manuel. PCO 3 Controller Operators Manuel. MLP Price Pages and Words. SQ Process flow. Order Process flow Factory Order Form Factory Collections Form Warranty Process flow Warranty Standard Hours List. Typical Wiring Diagrams Standard unit with available options (pdf). Typical Product Drawings (pdf) Launch Presentation (ppt)

Packaged Air Cooled Free Cooling APPLIED CHILLER PRODUCTS Competition

Packaged Air Cooled Free Cooling APPLIED CHILLER PRODUCTS Competition

YSFC Free Cooling Chiller Competition Stand Alone Dry Air Cooler. With thought all Packaged

YSFC Free Cooling Chiller Competition Stand Alone Dry Air Cooler. With thought all Packaged Air Cooled Chillers and Dry Air Cooler manufactures can provide the solution. Thermosyphen system. Carrier. Built-in separate Dry Air Cooler. Cosfi, Liebert Hiross, MTA, Uniflar. Dual Function - Free Cooling and Condenser Coil. ACM, Aermec, Airwell, Blue Box, Ciat, Clivet, Climaveneta, Emicom, Euroklimat, Daikin-Mc. Quay, Geoclima, Galletti, Lennox, Matri Clima, Rhoss, RC, Trane, Venco. APPLIED CHILLER PRODUCTS

YSFC Free Cooling Chiller Competition Geo. Clima, Emicon, Cosfi, Uniflair, YSFC, Climaveneta. APPLIED CHILLER

YSFC Free Cooling Chiller Competition Geo. Clima, Emicon, Cosfi, Uniflair, YSFC, Climaveneta. APPLIED CHILLER PRODUCTS

YSFC Free Cooling Chiller Competition Geo. Clima, Emicon, Cosfi, Uniflair, YSFC, Climaveneta. APPLIED CHILLER

YSFC Free Cooling Chiller Competition Geo. Clima, Emicon, Cosfi, Uniflair, YSFC, Climaveneta. APPLIED CHILLER PRODUCTS

YSFC Free Cooling Chiller Competition Geo. Clima, Emicon, Cosfi, Uniflair, YSFC, Climaveneta. APPLIED CHILLER

YSFC Free Cooling Chiller Competition Geo. Clima, Emicon, Cosfi, Uniflair, YSFC, Climaveneta. APPLIED CHILLER PRODUCTS

Packaged Air Cooled Free Cooling APPLIED CHILLER PRODUCTS Servicing Renewal Parts Contacts

Packaged Air Cooled Free Cooling APPLIED CHILLER PRODUCTS Servicing Renewal Parts Contacts

YSFC JCI Products and Service Departments have experience of many shared Component suppliers The

YSFC JCI Products and Service Departments have experience of many shared Component suppliers The Design of the YSFC has many similarities to our own YAES – YCAS and YLCS models. Using many common components that our Service Engineers and Renewal Parts Group are familiar with their availability and use. For example: Hanbell Compressors, Ziehl Fans, pumps, Alfa-Laval or Heatcraft Evaporator’s Plus many common refrigeration, electrical components. New components include The Carel PCO 3 controller with the Free Cooling Software. Hydronic system and Three way Valve. APPLIED CHILLER PRODUCTS

YSFC Service Training and Replacement Parts. Service Training A Service Trainer Course will be

YSFC Service Training and Replacement Parts. Service Training A Service Trainer Course will be organised at the Factory near Venice. During Q 4 FY 2009 The course will consist of: - • Product Overview (General Refrigeration system) • Theory of operation of the Free Cooling System. • Detail review of the PCO 3 Carrel controller and software. • Review end of line test and the Commissioning procedures. Replacement Parts • Must be purchased through JCI Renewal Parts Organisation who will have access to Hitema’s detailed bills of material’s for each product supplied. • Please ensure Model Number & Serial Number is given along with details of the Components requested. APPLIED CHILLER PRODUCTS

YSFC JCI-Hitema Contract Special Variations Drawing Approvals • Upon receipt of order the Factory

YSFC JCI-Hitema Contract Special Variations Drawing Approvals • Upon receipt of order the Factory will review the unit configuration and produce project specific physical & electrical drawings. • These will require Client approval before components purchase and manufacture commences. (Early reply would be required to ensure shortest possible lead times. ) Typical lead times 6 – 8 weeks after drawing approvals. Email communication of documentation and approvals is to be co-ordinated through Customer Services Group in Basildon. Commissioning registration • To initiate the warranty coverage the unit commissioning Completion date must be registered with the Basildon Customer Services team along with a copy of completed commissioning log report. • Specified system fill / commissioning procedures must be followed • Hitema reserves the right to request that any failed component be returned for analysis. • An agreed standard hours and labour rates repair times for replacement of faulty items. Warranty • In line with the current European standard policy of 18 months from factory collection. • All parts are with a full 18 month warranty with the exemption of the liquid Pump options. APPLIED CHILLER PRODUCTS

YSFC Communications Product Process JCI Sales and the Product Supply & Sourcing will jointly

YSFC Communications Product Process JCI Sales and the Product Supply & Sourcing will jointly work with Hitema. Responsibilities are as follows. • Product Supply & Sourcing. Product Manager Roger. J. Smeed@JCI. com 00441268246198. Account management, Maintain documentation and price list, Product Training, Product Management and application and special quotation support. • Factory will provide Engineering Support Through The Existing SQ System. Review requests for Special Quotation's. Specific product Technical / Engineering support. Product Manager Roger. J. Smeed@JCI. com 00441268246198. • Order Entry & Processing and Commissioning registration and Warranty management. Centralised through Customer Services Basildon. Orderentry CG-EUR-Basildon@jci. com 00441268246266. • After Sales Technical Operation support. Tim. Jennings@jci. com 00447976196714. • Renewal Parts hvacparts. cg-eur@jci. com 0044126824600. APPLIED CHILLER PRODUCTS

Have Your Say Any Questions? Have Confidence in Free Cooling and our New YSFC.

Have Your Say Any Questions? Have Confidence in Free Cooling and our New YSFC. Thank you. APPLIED CHILLER PRODUCTS