Operational Modes Flash measurements injection extraction safe Injection

  • Slides: 8
Download presentation
Operational Modes • Flash measurements (injection, extraction, safe) • Injection Frames • Display frames

Operational Modes • Flash measurements (injection, extraction, safe) • Injection Frames • Display frames • Profile frames • User defined TBT measurements • Fast time plots Applies to: • 2. 5 MHz and 53 MHz • Intensity ranges • Bunch structures • Position and intensity data • State definitions and Data buffers Verified by_________ date

Protons for anti-proton stacking and fixed target Energy 8 to 120 Ge. V Bunch

Protons for anti-proton stacking and fixed target Energy 8 to 120 Ge. V Bunch RF 53 MHz Bunch structure 84 bunches/batch, up to 6 batches however spaced 30 bunches/batch may be used for Fixed Target Bunch length (at 95%) 6 ns (8 Ge. V) 1. 5 ns (150 Ge. V, after bunch rotation) Intensity/bunch 5 E 9 to 200 E 9 Applies to: • All operational modes Verified by_________ date

Proton transfers to the Tevatron (uncoalesced) Energy 8 to 150 Ge. V Bunch RF

Proton transfers to the Tevatron (uncoalesced) Energy 8 to 150 Ge. V Bunch RF 53 MHz Bunch structure 30 to 84 uncoalesced bunches Bunch length (at 95%) 6 ns (8 Ge. V) 2. 5 ns (150 Ge. V) Intensity/bun ch 10 E 9 to 100 E 9 Applies to: • All operational modes Verified by_________ date

Proton transfers for collider operation Energy 8 to 150 Ge. V Bunch RF 53

Proton transfers for collider operation Energy 8 to 150 Ge. V Bunch RF 53 MHz Bunch structure 5 -9 bunches, coalesced into one bunch at 150 Ge. V Bunch length (at 95%) 6 ns (8 Ge. V) 2. 5 ns (150 Ge. V uncoalesced) 10 ns (150 Ge. V coalesced) Intensity/bunch 30 E 9 to 100 E 9 (uncoalesced) 50 E 9 to 400 E 9 (coalesced) Applies to: • All operational modes Verified by_________ date

Anti-proton transfers from Accumulator/Recycler Ring Energy 8 to 27 Ge. V Bunch RF 2.

Anti-proton transfers from Accumulator/Recycler Ring Energy 8 to 27 Ge. V Bunch RF 2. 5 MHz Bunch structure 4 consecutive bunches Bunch length (at 95%) 100 -200 ns (8 Ge. V) Intensity/bunch 5 E 9 to 150 E 9 40 ns (27 Ge. V) Applies to: • All operational modes Verified by_________ date

Anti-proton transfers to the Tevatron Energy 8 to 150 Ge. V Bunch RF 53

Anti-proton transfers to the Tevatron Energy 8 to 150 Ge. V Bunch RF 53 MHz Bunch structure 4 consecutive groups, spaced by 400 ns, of typically 5 (up to 9) 53 MHz bunches, coalesced into a single bunch at 150 Ge. V Bunch length (at 8. 5 ns (8 Ge. V) 3. 5 ns (150 Ge. V uncoalesced) 10 ns (150 Ge. V coalesced) 95%) Intensity/bunch 5 E 9 (uncoalesced) 10 E 9 to 150 E 9 (coalesced) Applies to: • All operational modes Verified by_________ date

53 Mhz measurement Requirements Measurement specifications 53 MHz bunch structure Measurement range 25 mm,

53 Mhz measurement Requirements Measurement specifications 53 MHz bunch structure Measurement range 25 mm, 30 mm for large aperture BPMs Absolute position accuracy 1 mm + 5% of actual beam position Relative position accuracy (3 ) 5% of actual beam position Position resolution (3 ) 0. 05 mm (0. 1 mm) Position linearity within 1. 5% of the slope of the BPM response at the center of the BPM over 15 mm Long-term position stability 0. 2 mm Relative intensity accuracy 10% (20%) Measurement specifications for 53 MHz bunch structure, narrow bandwidth mode. Values in parenthesis are for high bandwidth mode, with single turn resolution. Because of the non-linearity intrinsic to the MI BPM pickups, this specification only applies when the beam is off center on only one of the planes . Applies to: • Flash, Display, and TBT modes (both flash and user defined). • Single coalesced bunch, short (7 bunch) batch, full batch, multibatch beam. Verified by_________ date

2. 5 Mhz Measurement Requirements Measurement specifications Anti-protons of nominal intensity (>20 E 9/bunch),

2. 5 Mhz Measurement Requirements Measurement specifications Anti-protons of nominal intensity (>20 E 9/bunch), 2. 5 MHz bunch structure Anti-protons at low intensity (<20 E 9/bunch), 2. 5 MHz bunch structure Measurement range 25 mm, 30 mm for large aperture BPMs Absolute position accuracy 1 mm + 10% of actual beam position 1 mm + 20% of actual beam position Relative position accuracy (3 ) 10% of actual beam position 20% of actual beam position Position resolution (3 ) 0. 3 mm (0. 5 mm) 0. 5 mm Long-term position stability 0. 5 mm N/A Relative intensity accuracy 20% (30%) 30% Measurement specifications for 2. 5 MHz bunch structure, narrow bandwidth mode. Values in parenthesis are for high bandwidth mode, with single turn resolution. Because of the non-linearity intrinsic to the MI BPM pickups, this specification only applies when the beam is off center on only one of the planes. Applies to: • Flash, Injection, Display, profile, and TBT modes (both flash and user defined) • 4 consecutive bunches. Verified by_________ date