OIL CHIP DETECTOR HOUSING Capstone Team Honeywell July

  • Slides: 15
Download presentation
OIL CHIP DETECTOR HOUSING Capstone Team Honeywell July 24, 2019 Test Readiness Review Honeywell

OIL CHIP DETECTOR HOUSING Capstone Team Honeywell July 24, 2019 Test Readiness Review Honeywell Internal

Test Overview • Funding • TRR Purpose • Test Purpose & Requirements • Risk

Test Overview • Funding • TRR Purpose • Test Purpose & Requirements • Risk & Mitigation • Unit Under Test (UUT) • Testing Schedule and Status of Engine • Test Procedure • Instrumentation • Facility Control System Safety • Testing Protocols • Problem Reporting • Deliverables • Action Items 2 Honeywell Internal HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 2

Funding • Funding provided by Honeywell 3 HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or

Funding • Funding provided by Honeywell 3 HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 3

Readiness Review Purpose • Introduce and provide information on: - OCDH Background - Testing

Readiness Review Purpose • Introduce and provide information on: - OCDH Background - Testing Systems - Facility Requirements - Safety Systems - Schedule - Deliverables 4 HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 4

Testing Purpose & Requirements Pertaining to: • • • Shock and Vibration Pressure Flow

Testing Purpose & Requirements Pertaining to: • • • Shock and Vibration Pressure Flow Temperature / Fire. Proofing Weight / Size In order to satisfy: • • 5 Cycle Durability System Safety against overpressure OCD sensor environment System safety against Fire / Leaks HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 5

Risk Mitigation Two-piece housing design for greater manipulation of interior and exterior dimensions At

Risk Mitigation Two-piece housing design for greater manipulation of interior and exterior dimensions At least 0. 2 -inch-thick walls to allow a burst pressure of 20, 000 psig 304 Stainless steel chosen for durability and corrosion resistance Fireproof gasket material, that will be shield by the stainless-steel lid Altogether risk of structural failure is low due 6 HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 6

Unit Under Test • One unit provided by NAU Capstone Team - Housing, main

Unit Under Test • One unit provided by NAU Capstone Team - Housing, main body - Housing, Lid - Gasket - 3 x 304 M 10 socket cap screws 7 HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 7

Testing Schedule Testing to be completed on-site at Honeywell Testing will be completed at

Testing Schedule Testing to be completed on-site at Honeywell Testing will be completed at a future date TBD 8 HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 8

Testing Procedure • See accompanying document - F 1901 -0001 Benchtop Testing Procedure for

Testing Procedure • See accompanying document - F 1901 -0001 Benchtop Testing Procedure for the Oil Chip Detector Housing 9 HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 9

Instrumentation Digital Scale Calipers General Oil compatible pump Flow Related Dial Pressure Gauge Data

Instrumentation Digital Scale Calipers General Oil compatible pump Flow Related Dial Pressure Gauge Data Acquisition System Transducer Specialized Vibration Testing Table Also referenced in F 1901 -0001 10 HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 10

Facility Control System Safety FIRE EXTINGUISHER 11 SPLASH / BURST SHIELD HONEYWELL - CONFIDENTIAL

Facility Control System Safety FIRE EXTINGUISHER 11 SPLASH / BURST SHIELD HONEYWELL - CONFIDENTIAL SOLVENT / OIL DISPOSAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 11

Testing Protocol PPE 12 Fixture Priming Testing Procedure HONEYWELL - CONFIDENTIAL Requiremen t Validation

Testing Protocol PPE 12 Fixture Priming Testing Procedure HONEYWELL - CONFIDENTIAL Requiremen t Validation Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. Clean Up / Disposal File Number 12

Problem Reporting All problems will be documented during the tests Problems will be compiled

Problem Reporting All problems will be documented during the tests Problems will be compiled into a full report The report will be used to correct any problems found during testing 13 HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 13

Deliverables • Test Procedures Document • Problems During Test Document 14 HONEYWELL - CONFIDENTIAL

Deliverables • Test Procedures Document • Problems During Test Document 14 HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 14

Action Items • Assemble a Flow Testing Fixture (Document F 19010001) • Data Collection

Action Items • Assemble a Flow Testing Fixture (Document F 19010001) • Data Collection 15 HONEYWELL - CONFIDENTIAL Honeywell Confidential. Use or disclosure of information on this page is subject to the restrictions on the title page. File Number 15