OEM range OEM Air curtain range Air curtain
- Slides: 27
OEM range
OEM Air curtain range
Air curtain range PL 3500 RAR 3500 PL 3200 C PL 2500 RAR 200 PL 2200 C PL 1508 PL 1006
Door heater – PL 1006 • Compact door heater, 3 k. W • Low sound level • Standard length of 0, 6 m • Integrated control (fan speed and heat output) • Wall or ceiling mounted • Clean and timeless design • Air inlet on top of the unit
Air curtain – PL 2200 C • For door heights up to 2, 2 m • 1, 0 m/1, 5 m/2, 0 m lengths • Ambient, water or electrical • Horizontal • Built-in control system with remote • Easy installation • Easy maintenance and service
Air curtain – PL 3200 C • For door heights up to 3, 2 m • 1, 0 m/1, 5 m/2, 0 m lengths • Ambient, water or electrical • Horizontal • Built-in control system with remote • Easy installation • Easy maintenance and service
Air curtain – PL 2500 • For door heights up to 2, 5 m • 1, 0 m/1, 5 m/2, 0 m lengths • Ambient, water or electrical • Horizontal • SIRe regulation • Easy installation • Easy maintenance and service
Air curtain – PL 3500 • For door heights up to 3, 5 m • 1, 0 m/1, 5 m/2, 0 m/2, 5 m lengths • Ambient, water or electrical • Horizontal or vertical • SIRe regulation • Easy installation • Easy maintenance and service
Air curtain for recessed installation – RAR 200 • For door heights up to 2, 5 m • 1, 0 m/1, 5 m/2, 0 m lengths • Ambient, water or electrical • 3 electrical models, convertible into 12 possibilities • Easy installation • Easy maintenance and service • Easy to paint in any RAL colour
Air curtain for recessed installation – RAR 3500 • For door heights up to 3, 5 m • 1, 0 m/1, 5 m/2, 0 m lengths • Ambient, water or electrical • Intelligent regulation • Easy installation • Easy maintenance and service • Easy to paint in any RAL colour
Air curtain range – control solutions
Air curtain range – control solutions PL 2200 C and PL 3200 C Included in delivery PL 2200 C/PL 3200 C electrical and water ambient • Control panel on unit, and/or remote • Air speed, heating step, and temperature setting • Door contact automation (accessory)
Air curtain range – accessories PL 2200 C and PL 3200 C PL 2200 C/PL 3200 C accessories water control
Air curtain range – control solutions PL 2500/PL 3500/RAR 3500; PLS Choose between two solution packages: Basic RAR 3500 PL 2500/PL 3500 Ma nu al o pe rat ion Au tom ati cm od e Fle xib le m od e Op en mo de Ca len da r fu nct ion Filt er ala Sim rm ple BM Sc on tro l Competent
Air curtain range – control solutions PL 2500/PL 3500/RAR 3500; PLS Basic Choose between two solution packages: RAR 3500 Ma nu al o pe rat ion Au tom ati cm od e Basic PL 2500/PL 3500 PLSUB 1
Air curtain range – control solutions PL 2500/PL 3500/RAR 3500; PLS Basic Manual operation • On/off • Fan speeds • Heating steps Automatic mode • On/off • Temperature control RAR 3500 PL 2500/PL 3500
Air curtain range – control solutions PL 2500/PL 3500/RAR 3500; PLS Competent Choose between two solution packages: RAR 3500 PL 2500/PL 3500 Ma nu al o pe rat ion Au tom ati cm od e Fle xib le m od e Op en mo de Ca len da r fu nct ion Filt er ala Sim rm ple BM Sc on tro l Competent PLSUA 1
Air curtain range – control solutions PL 2500/PL 3500/RAR 3500; PLS Competent Expert on your entrance – Flexible and Open mode • Open vs. flexible mode of the doorway • Reduces sound level Calendar function Presets as required • • • Preset factory settings – easy to get started Adapt to your needs Make sure system is used RAR 3500 PL 2500/PL 3500
Air curtain range – control solutions PL 2500/PL 3500/RAR 3500; PLS Competent BMS RAR 3500 • Control by 0 -10 V signals PL 2500/PL 3500 Filter alarm • Clean filter when needed
Air curtain range – control solutions PL 2500/PL 3500/RAR 3500; Water controls RAR 3500 PL 2500/PL 3500
Air curtain range – accessories PL 2500
Air curtain range – accessories PL 3500 accessories PL 3 JK, vertical kit
Air curtain range – accessories RAR 3500 and AR 200 accessories RAR 3500 RAR 200
Air curtain range – controls and accessories RAR 200 controls SBN, control box el. fan speed (2 steps) heat output (2 steps) SBON, control box wa/am fan speed (2 steps) TS 2, 2 -step room thermostat 2 -way control valve MDCN, door contact shut off valve TS 1, room thermostat bypass valve 3 -way control valve adjustment valve actuator
OEM Fan heaters range
Portable fan heater Fan heater M • 2/3/5/9/15 k. W • 230 V~/230 V 3~/400 V 3~ • IPX 4 • Semko approval
OEM range
- Air rifle backstop curtain
- Hubungan air dengan tanah
- Oem coatmeter
- Oem adaptation layer
- Oem grid control
- Oem digital audio amplifier
- Nastf oem
- Oem physique
- Axicons
- Konecranes spare parts
- Oem ndacc system
- Servomechanism examples
- What is oem unbundling
- Oem location
- Foliate linux
- Oem recommendations
- Oem solar linker
- Solid based rapid prototyping manufacturer
- Rok vs oem
- Oem fleet management
- Qlik sense oem
- Mit mas
- As compared to long-range forecasts, short-range forecasts
- What does bernoulli’s principle state?
- Retromylohyoid
- Gas curtain
- Gresiofluvin
- A 193 kg curtain needs to be raised