Notes solid state vs gas detectors Silicon detector

  • Slides: 8
Download presentation
Notes solid state vs gas detectors Silicon detector ? GEM detector Scintillator detector Diamond

Notes solid state vs gas detectors Silicon detector ? GEM detector Scintillator detector Diamond detector Notes: solid state vs gas detectors Helium Replacement in Italy Frascati 2 -3 Dec 2013 P. Finocchiaro 1

materials for thermal neutron conversion: which one? 6 Li 10 B (0. 025) ≈

materials for thermal neutron conversion: which one? 6 Li 10 B (0. 025) ≈ 940 b available E 4. 78 Me. V 157 Gd (0. 025) ≈ 240 kb 113 Cd (0. 025) ≈ 20 kb (0. 025) ≈ 3840 b available E 2. 79 Me. V (and gamma rays) Notes: solid state vs gas detectors Helium Replacement in Italy large available E but in form of gamma rays: difficult neutron identification Frascati 2 -3 Dec 2013 P. Finocchiaro 2

materials for thermal neutron conversion: which one? 6 Li 10 B (0. 025) ≈

materials for thermal neutron conversion: which one? 6 Li 10 B (0. 025) ≈ 940 b available E 4. 78 Me. V (0. 025) ≈ 3840 b available E 2. 79 Me. V (and gamma rays) detection of 3 H and/or 4 He detection of 4 He (and 7 Li? ) lower kinetic energy ≈ 1 gamma ray /capture natural abundance: 7% vs 20% Notes: solid state vs gas detectors Helium Replacement in Italy Frascati 2 -3 Dec 2013 P. Finocchiaro 3

converter deposition technique solid state gas rough, simple, fast, cheap delicate, complex, slow, cost?

converter deposition technique solid state gas rough, simple, fast, cheap delicate, complex, slow, cost? substrate: glass, Al, C, . . . substrate: ceramic, . . . ? substrate thickness ≈ 1µm? substrate thickness ? adherence: not quite relevant adherence: mandatory Notes: solid state vs gas detectors Helium Replacement in Italy Frascati 2 -3 Dec 2013 P. Finocchiaro 4

converter thickness measurement solid state gas alpha source 4 He AFM? other? exploits the

converter thickness measurement solid state gas alpha source 4 He AFM? other? exploits the same detector additional equipment needed? rough, simple, fast, cheap delicate, complex, slow, cost? output in mg/cm 2 of converter output depends on chemistry? Notes: solid state vs gas detectors Helium Replacement in Italy Frascati 2 -3 Dec 2013 P. Finocchiaro 5

overall mechanical structure solid state gas robust, manageable delicate, bulky? little non-detector material? Notes:

overall mechanical structure solid state gas robust, manageable delicate, bulky? little non-detector material? Notes: solid state vs gas detectors Helium Replacement in Italy Frascati 2 -3 Dec 2013 P. Finocchiaro 6

operating features solid state gas vacuum compatible under vacuum? low voltage high voltage? very

operating features solid state gas vacuum compatible under vacuum? low voltage high voltage? very stable stability? closed sealed? easily assembled/disassembled needs gas flow? no physical/chemical agents on the converter sees gas, ions, electrical discharges Notes: solid state vs gas detectors Helium Replacement in Italy Frascati 2 -3 Dec 2013 P. Finocchiaro 7

conclusions? open discussion Notes: solid state vs gas detectors Helium Replacement in Italy Frascati

conclusions? open discussion Notes: solid state vs gas detectors Helium Replacement in Italy Frascati 2 -3 Dec 2013 P. Finocchiaro 8