Neutral Kaon Mass Measurement with CMD-2 Detector Alexander Zaytsev http: //cmd. inp. nsk. su/~azaitsev Novosibirsk, Budker INP SB RAS On behalf of CMD 2 Collaboration http: //cmd. inp. nsk. su DAFNE 2004 @ Frascati, Italy
VEPP-2 M Collider at Budker INP (Novosibirsk) VEPP-2 M average beam energy was calibrated using resonant depolarization technique
CMD-2 General Purpose Detector at VEPP-2 M Collider
Review of M(KS) Measurement Techniques Absolute pion momentum calibration technique: Critical pion opening angle technique: Full kaon decay reconstruction technique: and also could be represented by with CMD-2 choice
Systematic Effects and Corrections to Visible Mass Values (Initial State Radiation) Radiative Correction applied to compensate C. M. energy shift caused by ISR w RC (ISR) Nonlinearity Correction applied to take into account finite angular and momentum resolution effects w NC Bin-by-detector Electron-positron beams Energy Spread correction applied to Bin take into account initial particles energy distribution in w ES VEPP-2 M storage ring Charged pions energy losses (d. E/dx) in CMD-2 detector w DE Event-bymaterial (vacuum tube & DC) compensation Event. Compensate CMD-2 detector Magnetic Field experimentally measured nonunformity w MF (Final State Radiation) Radiative Correction applied to w RC (FSR) compensate reconstructed kaon mass shift caused by FSR Average value only A number of other negligibly small corrections w…