NATS 101 Lecture 9 Atmospheric Moisture

NATS 101 Lecture 9 Atmospheric Moisture

Hydrological Cycle Ultimate source of all fresh water 15% 50% 85% 50% Ahrens Fig.

Hydrological Cycle Ultimate source of all fresh water 15% 50% 85% 50% Ahrens Fig. 4. 1 85% of water vapor in atmosphere evaporates from oceans. About 50% of precipitation that falls over land is runoff, and the other 50% is transpired/evaporated. Water vapor molecules reside in atmosphere for one week.

Humid Air • Humid air is a mixture of molecules that make up dry

Humid Air • Humid air is a mixture of molecules that make up dry air (mostly N 2 and O 2) and lighter water vapor (H 2 O) molecules. • Each type of molecule contributes a fraction of total air pressure, or a partial pressure, proportional to the number molecules per unit volume. The partial pressure of water vapor is termed the vapor pressure.

Saturation Vapor Pressure • The partial vapor pressure at which the rate of evaporation

Saturation Vapor Pressure • The partial vapor pressure at which the rate of evaporation equals the rate of condensation in a closed system is called the saturation vapor pressure or SVP. The SVP effectively denotes the maximum water vapor that air the can “hold”. • SVP depends strongly on temperature. • Vapor pressure and SVP provide a measure of the actual water vapor content and the air’s potential capacity, respectively.

Williams p 62 dry E>C saturated E=C warmed. E >C cooled E<C SVP depends

Williams p 62 dry E>C saturated E=C warmed. E >C cooled E<C SVP depends on temperature. As temperature increases, more molecules are energetic enough to escape into the air. Concept applies to an ice surface. SVP over ice is lower because water molecules are bonded more tightly to ice. For the temperatures of interest, some water molecules are energetic enough to escape into atmosphere and SVP>0.

SVP and Temperature SVP nearly doubles with a 10 o. C warming SVP and

SVP and Temperature SVP nearly doubles with a 10 o. C warming SVP and T Graph Supercooled water droplets can exist to temps of -40 o. C For temps below 0 o. C, SVP runs 10%-30% lower over ice Ahrens Fig. 4. 5

Relative Humidity Air with a RH=100% is said to be saturated RH depends on

Relative Humidity Air with a RH=100% is said to be saturated RH depends on air temperature (SVP). RH changes by either changing air’s water vapor content or the air’s temperature.

Relative Humidity Ahrens Fig. 4. 6 The RH for constant water vapor content can

Relative Humidity Ahrens Fig. 4. 6 The RH for constant water vapor content can fluctuate greatly during the course of the day solely from the temperature changes

Relative Humidity (Ahrens, Appendix B) Consider air that is saturated at 0 o. C

Relative Humidity (Ahrens, Appendix B) Consider air that is saturated at 0 o. C Temp VP SVP RH 0 o. C 6 mb 100% o 10 C 6 mb 12 mb 50% 20 o. C 6 mb 23 mb 28% 30 o. C 6 mb 42 mb 14% 40 o. C 6 mb 68 mb 9%

Other Measures of Humidity

Other Measures of Humidity

Dew Point • DP-temperature to which air must be cooled at constant pressure to

Dew Point • DP-temperature to which air must be cooled at constant pressure to become saturated. Higher DP Higher water vapor content. • DP is a good indicator of the actual water vapor content since air pressures vary very little along the earth’s surface. • DP is plotted on surface weather maps. • DP depression (Temp-DP) is plotted aloft.

Arizona Dew Point Ranges Vapor Pressure 24 mb 12 mb 6 mb 3 mb

Arizona Dew Point Ranges Vapor Pressure 24 mb 12 mb 6 mb 3 mb Dew Point o 20 C 10 o. C o 0 C -10 o. C

Wet Bulb Temperature Wet Bulb Temp -Lowest temp to which air can be cooled

Wet Bulb Temperature Wet Bulb Temp -Lowest temp to which air can be cooled by evaporation of water into it. Warmer than dew point since moisture is being added to air which raises dew point. Measured with sling psychrometer. wet bulb dry thermometer Ahrens, Fig 4. 9

Wet Bulb Temperature (Ahrens, Appendix D) Wet bulb temperature lies about 30% of the

Wet Bulb Temperature (Ahrens, Appendix D) Wet bulb temperature lies about 30% of the way from the dew point to the temperature Application-Wet bulb temp gives maximum possible efficiency for a swamp cooler Month MAX Dew P Wet Bulb June 100 o. F 37 o. F 65 o. F o o o July 100 F 63 F 75 F

Heat Index Tucson Record MAX July MAX June MAX Humidity reduces the rate at

Heat Index Tucson Record MAX July MAX June MAX Humidity reduces the rate at which sweat evaporates. Thus, the cooling rate is lowered. Rocky Pt Summer Ahrens, Fig 4. 8

Humid Air is Less Dense Williams, p 72

Humid Air is Less Dense Williams, p 72

0. 5% lighter Williams, p 72

0. 5% lighter Williams, p 72

Summary: Moisture • Water vapor comes from the evaporation of sea water and resides

Summary: Moisture • Water vapor comes from the evaporation of sea water and resides in atmo. for ~1 week. • Air has a saturation level for water vapor • Saturation level depends on air temperature • Humid air is less dense than dry air • Water vapor content can be quantified by RH, dew point temp, wet bulb temp

Assignment for Next Lecture • Topic - Cloud and Fog Formation • Reading -

Assignment for Next Lecture • Topic - Cloud and Fog Formation • Reading - Ahrens pages 89 -96 • Problems - 4. 3, 4. 14, 4. 15