MV Capacitor units Advanced Power Quality training session

  • Slides: 49
Download presentation
MV Capacitor units Advanced Power Quality training session Presented by: Thierry LE GUILLOU Confidential

MV Capacitor units Advanced Power Quality training session Presented by: Thierry LE GUILLOU Confidential Property of Schneider Electric

The different types of MV Capacitor units Confidential Property of Schneider Electric | Page

The different types of MV Capacitor units Confidential Property of Schneider Electric | Page 2

MV Capacitors evolution Capacitors PLASTIVAR Impregnated paper With PCB Volume PCB = 7 à

MV Capacitors evolution Capacitors PLASTIVAR Impregnated paper With PCB Volume PCB = 7 à 20 litres 1950 1969 BIOVAR 1978 PROPIVAR NG PROPIVAR 1985 1997 2012

PROPIVAR NG - Technology Confidential Property of Schneider Electric | Page 4

PROPIVAR NG - Technology Confidential Property of Schneider Electric | Page 4

MV Capacitor technology Electrodes Dielectric Aluminium foil 1 Polypropylene 2 layers pp 1+pp 2

MV Capacitor technology Electrodes Dielectric Aluminium foil 1 Polypropylene 2 layers pp 1+pp 2 Polypropylene 2 layers pp 3+pp 4 Aluminium foil 2

MV Capacitor technology Propivar NG 1 1 Bushings: Porcelain > Insulated bushings compliant to

MV Capacitor technology Propivar NG 1 1 Bushings: Porcelain > Insulated bushings compliant to IEC 60137 2 Capacitor element: Electrodes: Folded Aluminium foil Dielectric: Polypropylene film > Lower electrical stresses > Minimized partial discharges 3 Internal connections: Large cross section > Low watt losses > Long lifetime 4 Dielectric fluid: Jarylec C 101 > Bio-degradable non-PCB fluid > High insulation strenght 5 Container (Grey, RAL 7038): Stainless steel blasted surface and paint (one layer of two-component 2 3 4 5 paint, plus one layer of hydro paint) > Low dielectric losses > Long lifetime > Fully TIG welded > High protection against corrosion and harsh climatic conditions

PROPIVAR NG - Ranges Confidential Property of Schneider Electric | Page 7

PROPIVAR NG - Ranges Confidential Property of Schneider Electric | Page 7

PROPIVAR NG Capacitor units Single phase unit Three phase unit Double phase unit

PROPIVAR NG Capacitor units Single phase unit Three phase unit Double phase unit

PROPIVAR NG Capacitor units Single phase unit Three phase unit Double phase unit

PROPIVAR NG Capacitor units Single phase unit Three phase unit Double phase unit

Unbalance protection L 1 L 2 L 3 L 1 x x N 2

Unbalance protection L 1 L 2 L 3 L 1 x x N 2 N 1 In > Single phase unit

Unbalance protection L 1 L 2 L 3 N 1 L 1 N 2

Unbalance protection L 1 L 2 L 3 N 1 L 1 N 2 x x x N 2 N 1 In > Double phase unit

PROPIVAR NG range – Single phase units Technology: Location: Reactive power: Operating frequency: Capacitor

PROPIVAR NG range – Single phase units Technology: Location: Reactive power: Operating frequency: Capacitor voltage range: All film capacitors Outdoor or indoor Up to 1000 kvar 50 Hz and 60 Hz 1 -17. 3 k. V (for network from 2. 4 to 34. 5 k. V when used in star connection) Current: Low losses Internal fuses Discharge resistors: Max. 160 A < 0. 2 W/kvar Built-in, standard residual voltage 75 V - 10 min. (option for 50 V - 5 min. ) Dielectric: Dielectric Fluid: Bushings: Terminals: Mounting brackets: Temperature range: Polypropylene film Jarylec C 101 2 in porcelain (1 on request) M 16 x 20 One per side -25°C to +50°C (-40°C to +55°C on request)

PROPIVAR NG range – Three phase units Technology: Internal delta connection Location: Reactive power:

PROPIVAR NG range – Three phase units Technology: Internal delta connection Location: Reactive power: Operating frequency: Capacitor voltage range: Current: Low losses Discharge resistors: All film capacitors Outdoor or Indoor Up to 600 kvar 50 Hz and 60 Hz 1 -12 k. V Max. 160 A < 0. 2 W/kvar Built-in, standard residual voltage 75 V - 10 min. (option for 50 V - 5 min. ) Dielectric: Dielectric Fluid: Bushings: Terminals: Mounting brackets: Temperature range: Polypropylene film Jarylec C 101 3 in porcelain M 16 x 20 One per side -25°C to +50°C (-40°C to +55°C on request)

PROPIVAR NG range – Double phase units Technology: All film capacitors 2 x single-phase

PROPIVAR NG range – Double phase units Technology: All film capacitors 2 x single-phase capacitors internal assembly Location: Outdoor or Indoor Reactive power: Up to 800 kvar = 2 x 400 kvar Operating frequency: 50 Hz and 60 Hz Capacitor voltage range: 1 -9 k. V (for network from 3, 3 to 15 k. V when used in star connection) Current: Max. 160 A Low losses < 0. 2 W/kvar Internal fuses Discharge resistors: Built-in, standard residual voltage 75 V - 10 min. (option for 50 V - 5 min. ) Dielectric: Dielectric Fluid: : Bushings: Terminals: Mounting brackets: Temperature range: Polypropylene film Jarylec C 101 3 in porcelain M 16 x 20 One per side -25°C to +50°C (-40°C to +55°C on request)

PROPIVAR NG - Internal fuses Confidential Property of Schneider Electric | Page 15

PROPIVAR NG - Internal fuses Confidential Property of Schneider Electric | Page 15

Protection with internal fuse For single-phase and double-phase capacitors only Capacitor WITH internal fuse

Protection with internal fuse For single-phase and double-phase capacitors only Capacitor WITH internal fuse > Immediate disconnection of the element short-circuited > Material and maintenance cost reduction > Capacitor can stay in service (lifetime increased) > Continuity of service ensured Capacitor WITHOUT internal fuse > > After the first failure, rapid failure of other elements Operation of external fuse Capacitor must be replaced Capacitor bank out of service > Possibility to program site maintenance High availability High reliability Low operation cost Reduced availability Higher operation cost

PROPIVAR NG range – Internal fuses Capacitor WITH internal fuses [Single-phase and double-phase only]

PROPIVAR NG range – Internal fuses Capacitor WITH internal fuses [Single-phase and double-phase only] Before failure Discharge of energy in parallel on the element that failed Low over-voltage – 1. 07 Un: > Immediate disconnection of the element short-circuited > Capacitor stay in service > After operation of the fuse Continuity of service ensured > Material and maintenance cost reduction

PROPIVAR NG range – No internal fuses Capacitor WITHOUT internal fuses After failure of

PROPIVAR NG range – No internal fuses Capacitor WITHOUT internal fuses After failure of one element Before failure High over-voltage – 1. 33 Un: > Rapid failure of other elements > Operation of external fuse > Capacitor must be replaced > Capacitor bank out of service

Unbalance protection • Made by mean of 1 CT + relay x x x

Unbalance protection • Made by mean of 1 CT + relay x x x In > • NB : Overload and short-circuit protection must also be ensured at the feeder level.

MV Capacitor units - Manufacturing Confidential Property of Schneider Electric | Page 20

MV Capacitor units - Manufacturing Confidential Property of Schneider Electric | Page 20

Power Quality factory in France Paris Geneva Pringy

Power Quality factory in France Paris Geneva Pringy

Manufacturing process • Brand new manufacturing line • Based on Lean Manufacturing rules and

Manufacturing process • Brand new manufacturing line • Based on Lean Manufacturing rules and 40 years experience • Controlled atmosphere (dust, humidity, temperature) manufacturing line according to ISO 14644 -1 Class level 8 • New automatic TIG welding cell to guarantee welding quality • Advanced impregnation process • 100% of the products are inspected by our quality department Winding machine Raw boxes Assembly line Welding machine

Propivar NG range: Key value "Safety" [ Fully compliant with standards ] • Propivar

Propivar NG range: Key value "Safety" [ Fully compliant with standards ] • Propivar NG capacitor fully complies with… • IEC 60871 -1, -2, and -4 • NEMA CP-1 • AS 2897 • Others standards on request

Propivar NG range: Key value "Reliability" [ 100% factory tested ] • Propivar NG

Propivar NG range: Key value "Reliability" [ 100% factory tested ] • Propivar NG capacitors are tested as per IEC 60871 standard requirements: • Capacitance measurement • Losses angle (tg ) measurement • Sealing test • Test of Internal discharge device • Voltage test between terminals • Current test between terminals and the case Propivar NG capacitors standard documents: • Routine test certificates (French / English) and User manual (French / English) Extremely high reliability

Propivar NG range: Key value "Green" [ Environmental safe ] • Non-PCB dielectric fluid,

Propivar NG range: Key value "Green" [ Environmental safe ] • Non-PCB dielectric fluid, with no impact on environment (biodegradable). • Propivar NG complies with ROHS directive, and complies with in REACH. • Schneider Electric PROPIVAR NG capacitors manufacturing plant is certified ISO 14001 (environment).

Quizz Confidential Property of Schneider Electric | Page 26

Quizz Confidential Property of Schneider Electric | Page 26

True/False PROPIVAR NG means PROPIVAR “Natural Gas”? E U R T FAL SE

True/False PROPIVAR NG means PROPIVAR “Natural Gas”? E U R T FAL SE

True/False No, NG means “New Generation? FAL SE

True/False No, NG means “New Generation? FAL SE

True/False PROPIVAR NG capacitor units have epoxy type bushings? E U R T FAL

True/False PROPIVAR NG capacitor units have epoxy type bushings? E U R T FAL SE

True/False No, PROPIVAR NG capacitor units have porcelain type bushings FAL SE

True/False No, PROPIVAR NG capacitor units have porcelain type bushings FAL SE

True/False PROPIVAR NG dielectric liquid is PCB free? E U R T FAL SE

True/False PROPIVAR NG dielectric liquid is PCB free? E U R T FAL SE

True/False Yes, PROPIVAR NG dielectric liquid is PCB free. E U R T

True/False Yes, PROPIVAR NG dielectric liquid is PCB free. E U R T

True/False To build a double star connection we need at least 6 single phase

True/False To build a double star connection we need at least 6 single phase units? E U R T FAL SE

True/False Yes, to build a double star connection we need at least 6 single

True/False Yes, to build a double star connection we need at least 6 single phase units. We can also use 9, 12, 15, … and more single phase units E U R T

True/False We can connect 6 three-phase delta connected capacitors in parallel? E U R

True/False We can connect 6 three-phase delta connected capacitors in parallel? E U R T FAL SE

True/False No, we limit to 3 the number of three-phase delta capacitors in parallel.

True/False No, we limit to 3 the number of three-phase delta capacitors in parallel. FAL SE

True/False We can have internal fuses in 3–phase delta connected capacitor units? E U

True/False We can have internal fuses in 3–phase delta connected capacitor units? E U R T FAL SE

True/False No, internal fuses is only applicable to single or double phase capacitor units?

True/False No, internal fuses is only applicable to single or double phase capacitor units? FAL SE

True/False IEC 60871 - Part 2 refers to environmental conditions for MV capacitors? E

True/False IEC 60871 - Part 2 refers to environmental conditions for MV capacitors? E U R T FAL SE

True/False No, IEC 60871 - Part 2 is related to special ageing test. PROPIVAR

True/False No, IEC 60871 - Part 2 is related to special ageing test. PROPIVAR NG complies with this standard. FAL SE

True/False 3 phase, delta connected capacitors must be protected by HRC fuses? E U

True/False 3 phase, delta connected capacitors must be protected by HRC fuses? E U R T FAL SE

True/False Yes, 3 phase, delta connected capacitors must be protected by HRC fuses. The

True/False Yes, 3 phase, delta connected capacitors must be protected by HRC fuses. The bank must also have an upstream protection against overvoltage and overcurrent? E U R T

True/False Single phase PROPIVAR NG capacitor units can be used in HV banks (220

True/False Single phase PROPIVAR NG capacitor units can be used in HV banks (220 k. V for example) E U R T FAL SE

True/False Yes, we connect several single phase PROPIVAR NG capacitor units for HV applications

True/False Yes, we connect several single phase PROPIVAR NG capacitor units for HV applications E U R T

True/False Three phase PROPIVAR NG capacitor units can be used in HV banks (220

True/False Three phase PROPIVAR NG capacitor units can be used in HV banks (220 k. V for example) E U R T FAL SE

True/False No, we cannot connect three phase units in series … FAL SE

True/False No, we cannot connect three phase units in series … FAL SE

True/False Double phase PROPIVAR NG capacitor units can be used in HV banks (220

True/False Double phase PROPIVAR NG capacitor units can be used in HV banks (220 k. V for example) E U R T FAL SE

True/False No, we cannot connect double phase units in series … FAL SE

True/False No, we cannot connect double phase units in series … FAL SE