Liquid Dehydration System Oil and Gas 7 Technologyslid































- Slides: 31
Liquid Dehydration System Oil and Gas 7 Technologyslid. Program
Liquid Dehydration System Oil and Gas Technology Program
Wet Gas Enters the Absorption Tower Oil and Gas Technology Program
Lean Glycol Enters Tower Oil and Gas Technology Program
Glycol Drained Oil and Gas Technology Program
Glycol Pump – Regulates Flow rate Oil and Gas Technology Program
Glycol Preheat Oil and Gas Technology Program
Rich-Glycol Filter Pot Oil and Gas Technology Program
Glycol Separator Oil and Gas Technology Program
Glycol Heated in Reboiler Oil and Gas Technology Program
Reboiler Stripper Column Oil and Gas Technology Program
Lean Glycol Drains Oil and Gas Technology Program
Strainer Oil and Gas Technology Program
Cooling Coil Oil and Gas Technology Program
Normal Operator Activities • Monitor and record readings from gauges and from temperature indicators • Check differential pressure (∆P) at Filters • Check for leaks • Monitor and record pump rate • Make minor adjustments when necessary to level, temperature, or pressure controls • Monitor reboiler burner flame characteristics • Monitor and record gas rate • Monitor and record dry gas moisture content Oil and Gas Technology Program
Routine Maintenance • Changing filters • Repair or replace pumps • Pull, clean, adjust burner • Pull and clean fire tube • Replace temperature indicators and gauges • Repair and replace controller and control valves • Clean flame arrestors Oil and Gas Technology Program
Loss of Glycol: Malfunction #1 Blow-by in the Absorber Tower Oil and Gas Technology Program
Loss of Glycol: Malfunction #2 Cracked Fire Tube Oil and Gas Technology Program
Loss of Glycol: Malfunction #3 Pump Leaks Glycol Oil and Gas Technology Program
Loss of Glycol: Malfunction #4 Foaming Oil and Gas Technology Program
Glycol Contamination: Malfunction Filter Collapse Normal Operation Oil and Gas Technology Program Clogged Filter
Saddle Plugging: Malfunction Multiples of these are found in the stripper to aid contact between wet glycol and glycol saturated steam. One Saddle Oil and Gas Technology Program
Reboiler Burner Efficiency: Malfunction #1 Flame Arrestor Plugging Oil and Gas Technology Program
Reboiler Burner Efficiency: Malfunction #2 Burner Tip Plugging Oil and Gas Technology Program
Reboiler Burner Efficiency: Malfunction #3 Poor Fuel Quality Oil and Gas Technology Program
Reboiler Burner Efficiency: Malfunction #4 Misadjusted or Improperly Operating Fuel-Gas Regulator Oil and Gas Technology Program
Pressure Safety Systems: Safety Valves and Pilots Oil and Gas Technology Program
Temperature Safety Systems Temperature Sensors Oil and Gas Technology Program
Toxic Gasses: Benzene and H S 2 Oil and Gas Technology Program
Leaks Glycol Oil and Gas Technology Program
Hot Surfaces and Liquids Oil and Gas Technology Program