Lange LDO Sensor What does LDO means Luminescence

  • Slides: 21
Download presentation
Lange LDO™ Sensor What does LDO means? Luminescence Dissolved Oxygen an optical and unique

Lange LDO™ Sensor What does LDO means? Luminescence Dissolved Oxygen an optical and unique way (patent pending) of measuring Dissolved Oxygen eliminates nearly all disadvantages of traditional electro chemical DO measurement

Lange LDO™ Sensor How does it look like? Sensor cap Sensor body Luminophor Photo

Lange LDO™ Sensor How does it look like? Sensor cap Sensor body Luminophor Photo diode red LED blue LED

Lange LDO™ Sensor How does it works? Sensor • The sensorcap is coated with

Lange LDO™ Sensor How does it works? Sensor • The sensorcap is coated with a luminescent polymer. Sensorcap • For the measurement the blue LED emits a pulse of light. • This passes through the transparent carrier material and transfers part of its radiation energy to this material. • Electrons from the luminophore are in this way raised from their initial energy state to a higher energy level. Luminescence indicatormolekules

Lange LDO™ Sensor How does it works? Sensor • The electrons return to the

Lange LDO™ Sensor How does it works? Sensor • The electrons return to the initial state via a number of intermediate levels (within ms) Sensorcap • The energy difference is emitted as a red radiation. • This light is detected by a photo diode. Luminescence indicatormolekules

Lange LDO™ Sensor How does it works? Sensor Membrane Photodiode LE D Incident blue

Lange LDO™ Sensor How does it works? Sensor Membrane Photodiode LE D Incident blue light Emitted red light Sensor cap with O 2 selective fluorescing molecules The intensity of the residual red light is proportional to oxygen concentration Oxygen from sample

Lange LDO™ Sensor How does it works? - If oxygen molecules are now in

Lange LDO™ Sensor How does it works? - If oxygen molecules are now in contact with the luminophore, - these are able to absorb the energy of the electrons in higher energy levels - and make it possible for the electrons to return to their initial state without the emission of radiation. - increasing oxygen concentration results in - a reduction of the intensity of the red radiation emitted. - this causes vibrations in the luminophore, result in electrons leaving the higher energy level more quickly -The lifetime of the red radiation emitted is thus shortened.

Lange LDO™ Sensor How does it works? • Both aspects are covered by the

Lange LDO™ Sensor How does it works? • Both aspects are covered by the term quenching. • Their effects are shown next page: the pulse of light sent out by the blue LED at time t=0 is incident on the luminophore that then emits red light immediately afterwards. • Maximum intensity (Imax) and the decay time for the red radiation are dependent on the surrounding oxygen concentration (the decay time t is defined here are the time between excitation and reduction in the red radiation to 1/e times the maximum intensity). Intensity curve for blue radiation producing excitation and red radiation emitted. To determine the oxygen concentration the life t of the red radiation is analysed. In this way the oxygen measurement is reduced to a purely physical measurement of the time.

Lange LDO™ Sensor How does it works? Normed Intensity Exitation puls Sensor Emisson profiles

Lange LDO™ Sensor How does it works? Normed Intensity Exitation puls Sensor Emisson profiles t 1 t 2 LE without O 2 with O 2 D Photo Diode LE D Sensor cap Time [µs] Oxygen Luminophor

Lange LDO™ Sensor How does it works? The LDO technology reduces the oxygen measurement

Lange LDO™ Sensor How does it works? The LDO technology reduces the oxygen measurement to a pure time measuement - the „Lifetime of Luminescense“

Lange LDO™ Sensor How does it works? A red LED is also present in

Lange LDO™ Sensor How does it works? A red LED is also present in the sensor The red LED acts as an internal standard (or reference) for a comparison to the red light given off by the luminescent coating. Between flashes of the blue LED a red LED of known intensity is flashed on the sensor element. Sensor cap LE D Photo Diode LE D

Customer benefits Lange LDO™

Customer benefits Lange LDO™

Key features of Lange LDO™ Sales arguments for Lange LDO™ l No calibration required

Key features of Lange LDO™ Sales arguments for Lange LDO™ l No calibration required l Without interference's l Stable measurement results l No more poisoning of the sensor l Independent from flow rate l Reduced cleaning frequency l Low maintenance efforts l Short response time l No polarisation time l Two year warranty on sensor cap

No calibration required Sales arguments for Lange LDO™ Background: - Lange LDO™ sensor is

No calibration required Sales arguments for Lange LDO™ Background: - Lange LDO™ sensor is very stable as it does not change it’s relevant characteristics ! - No anode to consume and no electrolyte to deplete extremely stable measurements - Adjustment of the whole optics due to an internal standard (red LED) - Each Lange LDO™ sensor cap is factory calibrated With Lange LDO™ the customer has not to calibrate his DO system anymore!

Stable measurement results Sales arguments for Lange LDO™ Background: - Lange LDO™ technology means

Stable measurement results Sales arguments for Lange LDO™ Background: - Lange LDO™ technology means no chemical inter action between the sample and the sensor element - Constant adjustment of all optical parts due to an internal standard (red LED) With Lange LDO™ the DO measurement results are stable over a longer period of time and thus more reliable

Independent from flow rate Sales arguments for Lange LDO™ Background: - Electro chemical DO

Independent from flow rate Sales arguments for Lange LDO™ Background: - Electro chemical DO meters consume Oxygen during the measurement Constant need for fresh sample and therefore a min. flow rate required - Lange LDO™ doesn’t consume DO. It requires the presence of a representative DO concentration at the sensor element only No flow rate required

Reduced cleaning frequency Sales arguments for Lange LDO™ Background: - No DO consumption during

Reduced cleaning frequency Sales arguments for Lange LDO™ Background: - No DO consumption during the measurement - DO has not to diffuse through a membrane - DO must only be in contact with the luminescent coating on the sensor cap Dirt has not the same negative influence with the optical method as with the conventional DO sensors

Low maintenance efforts Sales arguments for Lange LDO™ Background: -No membrane to replace -No

Low maintenance efforts Sales arguments for Lange LDO™ Background: -No membrane to replace -No more stretching of Teflon (very old procedure) and worrying about air bubbles -No electrolyte to foul or poison -No H 2 S poisoning of the electrolyte -No more punctured membranes -No more electrolyte depletion -No anode or cathode -No more coating of electrodes -No cleaning of anodes Only a sensor cap has to be exchanged once every two years : screw on / screw off

Without interference's Sales arguments for Lange LDO™ Background: - The Lange LDO™ principle is

Without interference's Sales arguments for Lange LDO™ Background: - The Lange LDO™ principle is selective to oxygen only. No interference with p. H swings, waste water chemicals or heavy metals like open galvanic cells Lange LDO™ is superior compared to (self cleaning) open galvanic DO cells as there are no interference’s

No more poisoning of the sensor Sales arguments for Lange LDO™ Background: - Lange

No more poisoning of the sensor Sales arguments for Lange LDO™ Background: - Lange LDO™ principle is not based on a chemical inter action between the sample and the sensor element - Lange LDO™ has been tested to a broad range of other chemicals. The sensor element is not affected by these (see data sheet) Lange LDO™ can measure reliable even in difficult applications

Short response time Sales arguments for Lange LDO™ Background: - With the optical measuring

Short response time Sales arguments for Lange LDO™ Background: - With the optical measuring principle DO only has to be present in front of the sensor element and not to diffuse through a thick (50 µm) Teflon membrane. Short response time can be programmed (t 90 < 30 s) for high dynamic processes

No polarization time Sales arguments for Lange LDO™ Background: - Lange LDO™ is based

No polarization time Sales arguments for Lange LDO™ Background: - Lange LDO™ is based on a new, optical technology. This technology does not need any “warm-up”. It is ready for use immediately. Switch the instrument on and start measuring!