New backplane pinout to accomodate 4 -wide star connections Use 4 routing layers =>

New backplane pinout to accomodate 4 -wide star connections Use 4 routing layers => 2 layers for interlock, 2 layers for monitor => for both cases have only I 2 C clocks on private layer (other 3 signals on other layer) PCB board stack: top layer : monitor routes SDA, INT, O inner 1 : GND plane inner 2 : monitor SCK inner 3 : VCC 1 plane inner 4 : VCC 2 plane (probably same voltage as VCC 1) inner 5 : interlock SCK inner 6 : GND plane bottom : interlock SDA, INT, O NOTE: no crosstalk problem : clocks and signals on separate planes 2 options for the monitor and interlock card backplane connectors: q 160 -pin connector => simple pin assignments : 1 row on the connector reaches one I/O card ü 96 -pin connector => more complex pin assignments : 4 rows reach 3 I/O cards; but OK 2021 -03 -03 ITk interlock meeting 2

SCK 19 SDA 19 SCK 18 Interlock backplane routing concept 4 -planes 4 -routing

SCK 19 SDA 19 SCK 18 Interlock backplane routing concept 4 -planes 4 -routing layers SCK 3 SCK 2 1 INT 19 O 19 4 SCK 17 21 21 SCK 2 SCK 19 24 25 28 2021 -03 -03 24 SCK 1 MON POS 1 4 POS 17 POS 18 ITk interlock meeting POS 19 ITL POS 20 3

From pin assignment spread sheet draft Option: Move lines 1 to 24 => 2

From pin assignment spread sheet draft Option: Move lines 1 to 24 => 2 to 25 Move line 25 to line 1 Option: Move lines 1 to 4 => 2 to 5 Move line 5 to line 1 Bus lines still available 2021 -03 -03 ITk interlock meeting 4

Crate power supply Estimate of module current consumption: T 2 I 16 channels of

Crate power supply Estimate of module current consumption: T 2 I 16 channels of buffer amps i. e. OPA 4317 (quad) : depends upon load resistance << 80 m. A. 32 channels of discriminators very low 16 channels of ADC 3 m. A port expanders (no optos) < 5 m. A total < 100 m. A Interlock driver cards for 36 interlocks (max value) typical 2 ma. Opto isolators 75 ma. worst case 8 ma. Opto isolators 300 ma. Þ Allow for 18 worst case I/O modules : 5. 4 A (typical 1. 5 A) Þ For monitor and interlock FPGA s : 2. 0 A Þ With safety factor of 2 : 14. 8 A Þ Acceptable crate power supply : 10 to 20 A. 5 VDC or 7. 5 VDC Example: MSP-100 -5 medical supply : 5 V 17 A US$ 63. 00 (also available at 7. 5 V 13 A) 2021 -03 -03 ITk interlock meeting 5

Preliminary cost estimates of crate components per crate (CAD$, taxes not included) Prototype Pre-prototype

Preliminary cost estimates of crate components per crate (CAD$, taxes not included) Prototype Pre-prototype quantities (2 crates) quantities (20) Production quantities (70) Backplane PCB, 4 -layers 62 mils $193 $57 $37 8 -layers 93 mils $356 $99 $67 Sub-rack, 3 U 84 HP, 295 mm, basic $149 $149 card guides 160 mm. $ 35 $ 35 Connectors, 30 and 96 pins $129 $ 81 FASTON tabs and sockets $ 7 $ 4. 50 Power wiring $ 10 $ 10. Power supply $ 85 $ 71. Power inlet, fused $ 5 $ 4 power cable $ 9 $ 7 Miscelaneous fasteners $ 10 TOTAL, 4 -layer option $632. 00 $408. 50 8 -layer option $795 $438. 50 2021 -03 -03 ITk interlock meeting 6

Backplane view from front of crate (Altium) 2021 -03 -03 ITk interlock meeting 7

Backplane view from front of crate (Altium) 2021 -03 -03 ITk interlock meeting 7

Crate view with custom backplane (Altium) 2021 -03 -03 ITk interlock meeting 8

Crate view with custom backplane (Altium) 2021 -03 -03 ITk interlock meeting 8

SPARE slides 2021 -03 -03 ITk interlock meeting 9

SPARE slides 2021 -03 -03 ITk interlock meeting 9

Backplane concerns Star traces spacing: 18 X 3 traces in 2. 5 inches Centerline

Backplane concerns Star traces spacing: 18 X 3 traces in 2. 5 inches Centerline spacing: 2. 5 /55 = 45. 45 mils With 7 mil tracks (38. 45 mils between traces) Trace length : 20 inches CROSSTALK table PCB Rise time Layer thickness 10 ns 20 ns 50 ns 100 ns 200 ns 60 mils 0. 72 0. 47 2 rows supply (other planes) 18 rows star routes 6 rows empty 10 rows => 0. 9” 0. 23 20 mils . 226 . 147 . 073 10 mils . 068 . 044 . 022 Space available for star routes: (2+18+6 -1) X 0. 1 = 2. 5 inches -A cross-talk <=. 05 is acceptable. Need: 10 mils or less layer thickness. 4 -layer with a properly specified pad stack -7 mils lines will have characteristic impedance of ~82 ohms. -The rise-time is dependant upon the pull-up resistors for open collector sources 2021 -03 -03 ITk interlock meeting 10

Interlock crate status Ø Backplane connectors selected: DIN 96 -pin for Monitor and Interlock

Interlock crate status Ø Backplane connectors selected: DIN 96 -pin for Monitor and Interlock modules DIN 30 -pin for I/O modules Ø Backplane topology defined: Separate routing layer for Monitor and interlock Power and ground planes I 2 C Star connections from Monitor or Interlock module to I/O modules Bussed power distribution (single voltage for hot swapping) Ø Connectors pin assignments complete Ø Mechanical components options for the crate selected (sub rack, card guides …) Ø PCB design under way (connector placement, mounting holes, schematics. ) Ø Selection of power supply modules candidates 2021 -03 -03 ITk interlock meeting 11