Intelligent Battery Care Safety instructions Keepower chargers can
Intelligent Battery Care
Safety instructions. Keepower chargers can be used to charge lead-acid batteries only (wet, gel, AGM, Ca/Ca…) Don’t use them to Ni-Cd, Ni-MH, Li-Poly and other types of batteries.
Battery. Construction. Vent cap(+) Plates Negative Cell Positive (-)terminal
Battery. Construction. Cell.
Battery. Construction. Cell. Positive (+) plate E=2, 13 V/ Cell 6 cells=12. 78 V Negative (-) plate H 2 SO 4 H 2 O Pb. O 2 Pb Electrolyt gravity 1. 28 g/ cm 3
Battery. Cell. Discharging. Positive (+) plate Negative (-) plate H 2 SO 4 H 2 O Pb. O 2 Pb Pb. SO 4 Electrolyte gravity for battery 11. 8 V approx. 1. 1 g/ cm 3
Battery. Cell. Charging. Positive (+) plate Negative (-) plate H 2 SO 4 H 2 O Pb. O 2 Pb Pb. SO 4 Wet battery max. voltage 2. 4 V/cell or 14. 4 V/12 V battery while charging.
Battery. Parameters 1. Nominal voltage 2. Capacity 3. Battery type 4. Battery voltage while not used 5. Maximum voltage while charging 6. Maximum charging current 7. Electrolyte gravity
Battery. Parameters Nominal voltage [V] • 6 V (3 cels) • 12 V (6 cells) • 24 V (2 batteries 12 V conected parallely) Never use 12 V charger to charge 6 V or 24 V battery!
Battery. Parameters Capacity [Ah] Capacity says how much energy a battery can store. Charging current [A] depends on the battery capacity. Smaller batteries have to be charged with smaller charging currents.
Battery. Parameters Battery types • Wet- (flooded) battery- electrolyte flows freely throughout the battery cell • Gel- diluted sulfuric acid is solidyfied to gel state by adding gel agent e. g. silicon dioxide • • AGM- electrolyte is absorbed by glass mat separator placed between plates Ca/Ca - plates and grids contain calcium preventing quick selfdischarging and rising gas limit voltage
Battery. Parameters Battery voltage [V] while not used Measuring voltage on the battery while not used user can verify battery condition. 12 V battery voltage facts: • 11. 8 V –deeply discharged • 12. 0 V-discharged • 12. 2 V-low charged • 12. 4 V –medium charged • 12. 7 -fully charged
Battery. Parameters Battery voltage [V] while not used Measuring voltage on the battery while not used user can verify battery condition. Battery voltage for charge level % Battery voltage [V] 11. 99 & Below 12. 00 to 12. 19 12. 20 to 12. 39 12. 40 to 12. 59 12. 60 to 12. 74 12. 75 & Above Charge level % Empty 25 to 50 50 to 75 75 to 85 85 to 100 Note: The state of charge is an approximation. The relationship between state of charge and voltage vary by battery condition, battery age, temperature.
Battery. Parameters Maximum voltage [V] while charging Maximum voltage (gas limit) 1. 2. 3. 4. Wet (flooded) 14. 4 V Gel 14. 4 V AGM 14. 8 V Ca/Ca 15. 9 V All Keepower chargers finish charging at gas limit voltage automatically. Charging over the gas limit voltage can damage the battery. Overcharging is especially dangerous for the health of gel and AGM batteries. Overcharged battery produce oxygene and hydrogen giving a dangerous explosive mixture.
Battery. Parameters Maximum charging current [A] To prevent damage the battery should be charged with current [A] not exceeding maximum recomended current by the batteries producer. Usually the maximum charging current is bigger for a battery with a bigger capacity.
Battery. Parameters. Maximum charging current [A] Charging current can’t exceed „ 3 h” current. For 120 Ah we can calculate maximum charging current: 120 Ah: 3 h=40 A Using higher charging current we can destroy the battery (separators and plates) due to rising electrolyte temperature.
Battery. Parameters Electrolyte gravity In batteries with access to cells electrolyte gravity can be measured by aerometer. Result gives important information regarding battery condition. Fully charged battery has electrolyte gravity 1. 28 g/cm 3 (normal gravity). Not fully charged battery has lower gravity of electrolyte. Low gravity (lower than normal) - battery needs charging.
Battery. Parameters Electrolyte gravity Higher gravity (higher than normal)battery lost water by overcharging (gassing). The Battery can be sulfurized because of too high gravity of acid. Separators can be destroyed as well. Battery with low acidic gravity can freeze below zero. Battery case can be destroyed from inside by ice. A frozen battery won’t work or be charged.
Battery. Parameters Electrolyte gravity. Charge (power) level. Temperature. Electrolyt gravity [g/cm 3] for charge level % Charge level 100% 75% 50% 25% 0% Electrolyt gravity [g/cm 3] 1. 28 1. 23 1. 20 1. 15 1. 10 „Starting” battery capacity Temperature [o. C] Battery 100% charged Battery 50% charged Battery 25% charged 25 100% 65% 40% 0 46% 32% 21% -18 25% 9%
Battery. Parameters Electrolyte gravity. Temperature. Freezing point. Specific gravity of electrolyte/freezing point Electrolytic gravity [g/cm 3] 1. 26 1. 225 1. 20 1. 15 1. 10 1. 05 Freezing point [o. C] -59. 4 -37. 2 -27. 2 -15 -7. 8 -2. 8
Important things to remember when buying a charger Do you…. 1. Do you want to charge all lead-acid battery types (wet, gel, AGM etc. ) with one unit? 2. Do you want to charge 12 V or 24 V batteries using one device? 3. Do you want to save time leaving the charger connected to the battery unattended ? 4. Do you want to be able to charge deeply discharged batteries with voltage 0 V ?
Important things to remember when buying a charger Do you…. 8. Do you want to be able to „kick” sulfurizated battery to start receiving energy? 9. Do you want to be able to keep the voltage on your car while replacing the battery or without the engine running (dealer station)? 10. Do you want to verify battery condition with your charger? 11. Do you want to be environmental friendly using charger with high efficiency level?
Important things to remember when buying a charger Choosing chargers that can say YES to all points. ☺☺☺
Products review MICRO SMALL XL-CON MEDIUM LARGE XL-PRO
Products review. Pictures.
Products review. Technical data. Type Nominal battery voltage Max current Battery capacity Battery type Power Input voltage Input frequency IP Weight Micro 12 V 0. 8 A 1. 2 Ah to 32 Ah wet/gel/AGM 16 W 230 Vrms ± 10% 50 Hz ± 3 Hz IP 65 0. 45 kg Small 12 V 4 A/1 A 3 Ah to 80 Ah wet/gel/AGM 60 W 230 Vrms ± 10% 50 Hz ± 3 Hz IP 65 0. 5 kg Medium 12 V 8 A 20 Ah to 160 Ah wet/gel/AGM 150 W 230 Vrms ± 10% 50 Hz ± 3 Hz IP 65 0. 9 kg
Products review. Technical data. Type Nominal battery voltage Max current Battery capacity Battery type Power Input voltage Input frequency IP Weight Large 12 V 15 A 40 Ah to 300 Ah wet/gel/AGM 240 W 230 Vrms ± 10% 50 Hz ± 3 Hz IP 44 1 kg XL-con 12 V/24 V 30 A/15 A 90 Ah to 600 Ah wet/gel/AGM 525 W 230 Vrms ± 10% 50 Hz ± 3 Hz IP 44 1. 36 kg XL-pro 12 V/24 V 1 A- 30 A or 1 A-15 A step 1 A 3 Ah to 600 Ah wet/gel/AGM/Ca/Ca 525 W 230 Vrms ± 10% 50 Hz ± 3 Hz IP 44 1. 36 kg
Keepower charger set. Equipment. Keepower Micro set contains: Charger Battery clamps Motorbike cable Manual instruction
Keepower charger set. Equipment. Keepower Small set contains: Charger Battery clamps Cigarret adaptor Motorbike cable Manual instruction 17 languages
Keepower charger set. Equipment. Keepower Medium set contains: Charger Battery clamps Cigarret adaptor Motorbike cable Manual instruction 17 languages
Keepower charger set. Equipment. Keepower Large set contains: Charger Battery clamps Motorbike cable Manual instruction 17 languages
Keepower charger set. Equipment. Keepower XL-con set contains: Charger Manual instruction 17 languages
Keepower charger set. Equipment. Keepower XL-pro set contains: Charger Manual instruction 17 languages
Keepower. Connecting. Flash light The charger contains a flash light that can be used as a small working lamp when using the charger in a dark room. Flash ligh helps to recognize battery polarity and connect clamps.
Keepower. Connecting.
Tester. Battery tester section The battery must be at ambient temperature (20°C) and at least 4 hours in resting state (without charging any vehicle or intelligent battery care) to ensure that the displayed value is reliable.
Tester. Test results Discharged Full Low Medium Deeply discharged Battery can be charged in the normal No charging required. If battery needs to be quickly charged, charging mode. choose Intelligent boostcharge.
Tester. Test result XL-pro. Deep. There is no reason to charge. However a Discharged: Full: Medium: The battery can be charged with Low: Discharged The battery can be charged with in the battery: If battery symbol is flashing softcharge is activated Immediate charging is needed. Charging will small top-up charge can normally be added. proper (Wet, gel etc. ) charging mode. proper (Wet, Gel etc. ) charging mode. . automatically when charging starts. start with Softcharge.
Charging. To start charging plug connector to mains….
Charging. …. then select program To select charging program push selection button
Charging. Keepower Micro 0, 8 A [12 V] available programs Keepower Micro Charge battery in four step charging program. Program starts after connection to battery and power; yellow LED is on. Charger finishes charging automatically when voltage 14. 4 V is reached; green LED Fully charged is on.
Charging. Keepower Small 4 A/1 A [12 V] available programs Normal charging Cold Bike Boostcharging: charging mode: : is used on is the same as a “Normal Charging” but the is used when trying to repair deep -normal batteries (wet, open type), -current is limited to 1 A discharged batteries. when the battery is below -5 ºC -maintenance-free, gel and sealed battery -(only Keepower Small). Boost is indicated when Normal and for most AGM GEL batteries. with a gas limit at 14. 0 V in Bulk charging and The gas limit is 14. 4 V in Bulk charging and Cold LED on simultaneously. Boost is 14. 4 V in Aftercharge. 14. 8 V in Aftercharge. selected by pressing the selection button for 5 sec.
Charging. Keepower Medium 8 A [12 V] available programs Normal charging Supply Cold Boostcharging mode: Mode: : is used on The Supply mode is used as a power is used on is used when trying to repair deep discharged -normal batteries (wet, open type), supply e. g. when the car is in a -batteries. Boost is indicated when Normal and when the battery is below -5 ºC -maintenance-free, gel and sealed battery showroom and the cars facilities is used -Cold LED on simultaneously. Boost is selected and for most AGM batteries. with a gas limit at 14. 0 V in Bulk charging without the motor running. Is used to The gas limit is 14. 4 V in Bulk charging and by pressing the selection button for 5 sec. and 14. 4 V in Aftercharge. keep device’s memory contest when old 14. 8 V in Aftercharge. battery is replaced with new.
Charging. Keepower Large 15 A[12 V] available programs Normal charging Boost Supply Cold charging mode: Mode: : is used on is used when trying to repair deep The Supply mode is used as a power is used on -normal batteries (wet, open type), discharged batteries. supply e. g. when the car is in a -when the battery is below -5 ºC -maintenance-free, gel and sealed battery Boost is indicated when Normal and showroom and the cars facilities is used - and for most AGM batteries. with a gas limit at 14. 0 V in Bulk charging Cold LED on simultaneously. Boost is without the motor running. Is used to The gas limit is 14. 4 V in Bulk charging and 14. 4 V in Aftercharge. selected by pressing the selection keep device’s memory contest when old 14. 8 V in Aftercharge. button for 5 sec. battery is replaced with new.
Charging. Keepower XL-con 30 A[12 V] 15 A[24 V] available programs Supply Cold Boostcharging mode: Mode: : Normal charging The Supply mode is used as a power supply e. g. is used on is used when trying to repair deep is used on when the car is in a showroom and the cars --normal batteries (wet, open type), discharged batteries. when the battery is below -5 ºC facilities is used without the motor running. Is --maintenance-free, gel and sealed battery Boost is indicated when Normal and for most AGM batteries. used to keep device’s memory contest when The gas limit is Cold LED on simultaneously. Boost is The gas limit of old battery is replaced with new. 14. 4 V/ 12 V or 28. 8 V/24 V in Bulk mode and selected by pressing the selection 14. 0 V /12 V or 28. 0 V/24 V in Bulk mode and 14. 8 V/12 V or 29. 6 V/24 V in Aftercharge mode. button for 5 sec. 14. 4 V/12 V or 28. 8 V/24 V in Aftercharge mode
Keepower XL-pro. Selection of language.
Keepower XL-pro. Selection of language. Polski English Deutsch Nederlands Francais Dansk Deutsch Francais Espanol Polski Dansk Nederlands Francais Dansk Espanol Nederlands Polski Turning the charger on Making a selection Activate language selection Scrolling to select the language
Charging. Keepower XL-pro. Menu structure. Battery connected • Charge • Select [select nominal voltage] • 12 V • 24 V • Select [select capacity Ah] • minimum 3 Ah 1 A to >200 Ah 30 A [12 V mode] or • minimum 3 Ah 1 A to >100 Ah 15 A [24 V mode] • Select battery type • Wet • Gel • AGM • Calcium Start ? Start? Arrow Back is used for going back to the previous menu Arrow Up is used for moving the cursor up in the menu Arrow Down is used for moving the cursor down in the menu Select buttons Making a selection in the menu
Charging. Keepower XL-pro. Menu structure. Battery connected • Boost • Select [select nominal voltage] • 12 V • 24 V • Select [select capacity Ah] • minimum 3 Ah 1 A to >200 Ah 30 A [12 V mode] or • minimum 3 Ah 1 A to >100 Ah 15 A [24 V mode] • Select battery type • Wet • Gel • AGM • Calcium Start ? Start? Arrow Back is used for going back to the previous menu Arrow Up is used for moving the cursor up in the menu Arrow Down is used for moving the cursor down in the menu Select buttons Making a selection in the menu
Charging. Keepower XL-pro. Menu structure. Battery connected • Supply • Select [select nominal voltage] • 12 V • 24 V • Select [select maximum current] • 1 A to 30 A [12 V mode] or • 3 Ah 1 A to 100 Ah 15 A [24 V mode] Arrow Back is used for going back to the previous menu Arrow Up is used for moving the cursor up in the menu Arrow Down is used for moving the cursor down in the menu Select buttons Making a selection in the menu
Charging regime. Absorption Maintenance Aftercharge Bulk charging Desulfurization Test: Softcharge Absorption charges the battery up to Maintenance is intended to Aftercharge is used to charge the Bulk charging is used to charge Desulfurization is used for The test checks the battery for Softcharge is used for deeply 98 % of the full capacity. sustain 100 % battery output battery up to 100 % of the full the battery up to 85 % of the batteries which were out of use damages. discharged batteries. The over a long time. capacity. full capacity. for a longer period of time. battery is charged until ready Constant voltage charging is very The battery charger measures The voltage is raised by 0. 4 V If battery voltage drops down for bulk charging. recommended phase making that continuously the voltage. compared to Bulk charging. Constant current charging is a quick battery is damaged. cells are charged to the same level. If it falls below 12. 8 V for 12 V very efficient and safe charging Low current charging prevents battery or 25. 6 V for 24 V Low current Aftercharge phase mode. damages frequently caused by battery charging restarts. ensure that overcharging will not high current charging while Using this function battery can occur. Constant current charging in battery is deeply discharged. be maintained over long period compare to traditional e. g. 24 months. charging is c. a. twice effective. Current [A] Battery Voltage [V]
Charging regime. months weeks days
Usable tip. To charge the battery more than maximum capacity given in technical specification, after 18 h of charging, restart charger- press selector 3 times to choose program again (choose program once again in XL-pro).
Competitive advantage. Technology. Keepower has all standard and extra features -Keepower can charge all lead-acid batteries (wet, gel, AGM, etc. ). - Keepower protects car’s electronic system, DIN 40839. - Keepower has gas limit regulation – no need to attend the battery. - Keepower produce no sparks while in charging mode. - Keepower has protection against short circuit. - Keepower can keep voltage in instalation- has Supply mode. - Keepower can „kick” battery to start using Boost mode. - Keepower obtain IP 65 or 44.
Competitive advantage. Functional properties. 1. We can start charging at battery voltage down to 0 V 2. We indicate if a battery needs help-battery tester 3. We can help battery to start-intelligent boost 4. Intelligent boost adjusts to the condition of the battery 5. We follow the battery manufacturers recommandations 6. Our charger never gives up on at battery
Competitive advantage. Charging regime. Why is Keepower better than traditional chargers? After charging Keepower doesn’t automatically finish charging finish atomatica charging. lly. This No protects attending battery during Traditional Using low current charger while does uses charging not decreasing protect deeply charging battery discharged while current. battery This charging regime Keepower charges battery using optimal method ofdeeply charging: aginst charging overcharging. may cause overcharging (lose water) andvoltage. other Keepower discharged makes charging protects and deliver process battery big longer current against and at damages. ineffective. low battery constant current charging. Maximum, safe current value problems. isn’t exceeded, maximum energy is delivered.
Competitive advantage. Warranty. Why is Keepower better than other chargers? Inelco offers 24 months warranty for Keepower chargers.
Why buy a Keepower charger? 1. 8. Adjustable technology angle –deeply easy available todischarged mount for on everyone. wall. 11. 3. 4. 5. 6. 9. 7. 2. Advanced Highest Lowest Flashlight. Battery 12 V/24 V Patented Possible Uniquestandby tester efficiency design. to auto antihook revive inconsumption Keepower rate clamps. on the XL-con. on market the batteries. market. (92 -93%). 10. Charging mobile phones and I-pod’s through USB (Xl-con and Xl-pro).
Thank you for your attention !