Indoor Power Conditioning Voltage Regulator Three Phase 10 – 250 k. VA

Indoor Power Conditioning Voltage Regulator Three Phase 10 – 250 k. VA

What is the Piranha? It is a three phase Power Conditioning Voltage Regulator. The

What is the Piranha? It is a three phase Power Conditioning Voltage Regulator. The Piranha offers exceptional reliability with a Mean Time Between Failure greater than 200, 000 hours in worst case conditions and Mean Time To Repair of less than 2 hours. The front access control makes it easy to maintain and ensures maximum up time. The Piranha from DSPM “Takes a Bite Out of Power Problems” It is available in power levels of 10, 20, 30, 50, 75, 100, 125, 150 and 250 k. VA

What makes the Piranha different? • Display monitor keeps you in control 24/7. •

What makes the Piranha different? • Display monitor keeps you in control 24/7. • Dependable DSP/PWM technology for unsurpassed reliability. • Economical for the lowest overall cost for your light safety, with an Energy Star Rating. • High efficiency of >96%. • A reliability of over 200, 000 hours. • Comes standard with a main input breaker. • Easy front access. • With a proven non-linear load capability. • Regulation bypass switch that enables the unit. • Input and output filters. • 5 Year power train warranty • Listed UL 1950

Specifications *Standard Power Levels. . . 10, 20, 30, 50, 75, 100, 125, 150,

Specifications *Standard Power Levels. . . 10, 20, 30, 50, 75, 100, 125, 150, 250 k. VA *Input Voltage. . . . 208, 240 or 480 VAC *Input Voltage Range. . . . +10%, -15% Power Factor. . . . 0. 95 *Frequency Range. . . . . 50, 60 or 400 Hz *Output Voltage. . . 120/240, 208 Y/120 or 480 Y/277 VAC *Output Voltage Regulation. . . ± 1% Typical, ± 2% Max Response Time. . . 1 cycle correction with standard regulation Harmonic Distortion. . . . <1% added Common Mode. . . . -152 d. B Normal Mode. . . . -60 d. B (0. 1 Hz to 1 m. Hz) Overload (Inrush). . . 200% of full load for 10 seconds Transformer. . . . Shielded, isolation transformer or copper wound, buck-boost transformer Efficiency. . . . . ≥ 96% at full loads; 98. 5% at light loads Load Power Factor. . . . . 0. 3 leading or lagging to unity Audible Noise. . . . <58 d. B measured on Response Curve “A” Safety Agencies. . . Listed to UL standard 1950 Operating Temperature. . . 0º to 40ºC (32º to 104ºF) Storage Temperature. . . . -20º to 60ºC (-4º to 140ºF) Humidity. . . . . 0 - 95%, Non-condensing *Consult factory for others. Specifications subject to change without notice.

System Drawing: Specification Chart:

System Drawing: Specification Chart:

Brochure For your convenience you can download the brochure with all the information about

Brochure For your convenience you can download the brochure with all the information about our Piranha from our website: www. dspmanufacturing. com

Data Sheet For your convenience you can download the data sheet with all the

Data Sheet For your convenience you can download the data sheet with all the information along with how to order our Piranha from our website: www. dspmanufacturing. com

Other Downloads For your convenience you can also download the technical specification, manual, field

Other Downloads For your convenience you can also download the technical specification, manual, field service documents, and white papers for the Piranha from our website: www. dspmanufacturing. com

If you have any other questions or would like more information Call 1. 877.

If you have any other questions or would like more information Call 1. 877. DSPM. POWER 1. 877. 377. 6769 Thank You! 089 -0030 -01