IHE Cardiology Technical Committee Profile update for DICOM

  • Slides: 7
Download presentation
IHE Cardiology – Technical Committee Profile update for DICOM WG 1 Nov. 4, 2009

IHE Cardiology – Technical Committee Profile update for DICOM WG 1 Nov. 4, 2009

IHE-C 2010 work overview • Update on IHE-C – Planning committee Chairs – Dr.

IHE-C 2010 work overview • Update on IHE-C – Planning committee Chairs – Dr. Alan Katz (ACC), Dr. David Slotwiner ( HRS) – Technical committee Chairs – Tom Dolan ( Philips) Antje Schroeder ( Siemens) • Profiles for 2011 Connectathon (PC voting rank) – – Cardiology Report Content (1) ECG Workflow (2) Image enabled office (3) EP-implant workflow (4) • White. Paper for 2010 delivery (5) • Key milestones – Public comment – April 26 2010 -June 1 2010 – Trial Implementation text – June 15 2010 – Connectathon – January 2011 12/7/2020 2 IHE Cardiology TC Meeting

Cardiology Report Content • Based on the ‘Health Policy Statement on Structured Reporting’ and

Cardiology Report Content • Based on the ‘Health Policy Statement on Structured Reporting’ and the associated ‘Key Data Element Definition for Cardiac Imaging’ from the ACC a standard template for Cardiac Imaging Reports should be developed • Key use case: • • • Existing Standards and Profiles • • Cardiac Referral Trigger for clinical decision support IHE Evidence Document and DICOM SR templates (Cath, Echo, Stress, …) XDS-MS for medical summaries for referral and consultation report content HL 7 CDA Basic Diagnostic Imaging Report Implementation guide Discussion • • • 12/7/2020 Close coordination with Radiology and PCC domain necessary Just Cardiac Imaging Report Has to be harmonized with the EHR lexicon work of the ACC Informatics Committee. 3 IHE Cardiology TC Meeting

Resting ECG Workflow • Define a profile similar to Scheduled Workflow to address patient

Resting ECG Workflow • Define a profile similar to Scheduled Workflow to address patient registration, ordering of a resting 12 lead ECG test, performing the test, reporting and storage of the ECG data in a standardized format • Key use case: • Similar workflows as described in scheduled workflow, but used for resting ECG • Existing Standards and Profiles • Based on actors and transactions of scheduled workflow. Intermittently connected acquisition device needs to be covered. • Discussion • Focus on resting ECG only • Which Dicom wave form standard to use • Access to demographics outside of “scheduled workflow” 12/7/2020 4 IHE Cardiology TC Meeting

Image Enabled Office • Address integration of medical imaging equipment into an office environment,

Image Enabled Office • Address integration of medical imaging equipment into an office environment, in order to fulfill the meaningful use criteria for image integration in 2015 • Key use case: • • Existing Standards and Profiles • • • Scheduling, Image acquisition, reporting, access to EMR, document exchange with referring physicians in an ambulatory cardiology office. IHE workflow profiles like ECHO, CATH, SWF, STRESS IHE Evidence Document and Key Image Note profiles IHE XDS, XDS-I, XDS-MS, PIX, PDQ profiles for cross enterprise sharing of information DICOM WADO Discussion • • 12/7/2020 Further clarification on scope needed Address ECG use in this context White paper or profile Since it is crucial for meaningful use criteria 2013/2015, it should be tested at Connectathon in 2011 5 IHE Cardiology TC Meeting

EP-implant Workflow • EP implant Lab is a multi-modality environment and uses equipment from

EP-implant Workflow • EP implant Lab is a multi-modality environment and uses equipment from multiple vendors, which up to now are mostly unconnected. Coordinating the different devices within the EP lab and the information exchange between them is the objective of this profile. • Key use case: • Information management and device coordination during device implantation in the EP Lab. • Existing Standards and Profiles • • IHE workflow profiles like CATH IHE Evidence Document IHE XDS-MS (medical summaries) IHE RID (Retrieve Information for Display) • Discussion • Workflow or Document exchange: It was decided that this would be a workflow profile • Scope boundary issues – might be necessary to split into two parts: Data exchange in EP lab and reporting 12/7/2020 6 IHE Cardiology TC Meeting

3 D/4 D Echo Workflow Whitepaper • Define clinical use case on storage and

3 D/4 D Echo Workflow Whitepaper • Define clinical use case on storage and display of 3 D Echocardiograms. This includes coordination with DICOM working groups to develop presentations states. • Key use case: • • • Exchange 3 D US data between Scanner, PACS and Post Processing workstation for image review and 3 D measurements Existing Standards and Profiles • DICOM Supplement 43 • IHE Echocardiography Workflow Discussion • Handling of the blending pipeline in order to adequately display the different data types • Lack of n. D presentation state object to represent derived views • Supplement 43 was only recently approved, nevertheless it would be good to start working on this right away. 12/7/2020 7 IHE Cardiology TC Meeting