ICASS Door Access System THE LEADING INNOVATOR OF

  • Slides: 26
Download presentation
I-CASS – Door Access System THE LEADING INNOVATOR OF SECURITY SYSTEM

I-CASS – Door Access System THE LEADING INNOVATOR OF SECURITY SYSTEM

Table Of Content 1. 2. 3. 4. 5. 6. 7. 8. Introduction to I-CASS.

Table Of Content 1. 2. 3. 4. 5. 6. 7. 8. Introduction to I-CASS. Comparison with K-series. System Component. System configuration. System Technology. I-Cass Features. Technical Specification. Precaution & Maintenance.

System Introduction(1) • Max. 32 doors access control system. • Categorized into 2/4/8/12/16/24/32 doors

System Introduction(1) • Max. 32 doors access control system. • Categorized into 2/4/8/12/16/24/32 doors version. • Combination of existing door access system, time attendance system, and alarm monitoring system. T-series K-series FEP : Multi-door interlocking features : Auxiliary Output relay based on defined transaction. : Supervised alarm input points.

System Introduction(2) § Integrated with S-series, K-series, T-series, Commando, Centurion and FEP alarm monitoring

System Introduction(2) § Integrated with S-series, K-series, T-series, Commando, Centurion and FEP alarm monitoring system design concept. § § § § Bring in wireless messaging technology. Short message service among very doors. Huge user and transaction storage capacity. High speed processing and respond time. Interactive blue light graphic LCD display Emergency over ride key( Electronic Key). Long reading range for proximity technology. Ready for mifare and wiegand 26/32 bits.

System Introduction(3) 1. People choose I-CASS for its flexibility usage in security access control

System Introduction(3) 1. People choose I-CASS for its flexibility usage in security access control and other relevant application such as: 1. Multi-door anti-pass back that handling max. 32 doors operation. 2. Multi-door interlocking features that only allow one door to grant access at a time. 3. Guard Tour application that enabling patrol guard perform checking duty. 4. Ethernet and GSM ready for internal and external communication. 5. Alarm break in protection. 6. Fire alarm emergency exist.

1. System Introduction(4) • Dual card entry mode and access counter mode for restricted

1. System Introduction(4) • Dual card entry mode and access counter mode for restricted access area. • CCTV and building automation integration. • 125 Khz and 13. 56 MHz proximity technology interfacing. • I-CASS is designed to meet customer application including – Door access control – Guard tour patrol – Time Attendance – Alarm monitoring – Car Parking control – Building automation – Fire alarm panel integration – CCTV integration – Smart. Card based solution

1. How security handled in ICASS? • • System wiring design Electronic key design

1. How security handled in ICASS? • • System wiring design Electronic key design Communication data protection Emergency event or alert Low power and main fail power detection Communication break down protection Watch dog for safe guard

1. Benefit of using I-CASS • To have more card user capacity in the

1. Benefit of using I-CASS • To have more card user capacity in the system. • To have a high speed and fast processing time for every operation. • To have a large door capacity controlled under one controller. • To have a alarm monitoring features at every door. • To have a guard tour features at every door. • To have SMS messaging service among door reader. • To have variety choice of operation mode at every door. • To have interactive graphic display on every door reader. • To have emergency over ride system • To have Ethernet ready capability

1. Comparison with existing controller(1) Feature/Spec. K-series I-CASS Interlocking No 5 door per group

1. Comparison with existing controller(1) Feature/Spec. K-series I-CASS Interlocking No 5 door per group (100 group) Anti-pass back Available among max. 8 Available among doors Max. 32 doors Dual card access No Available (100 match code) Access Counter No Available on every door setting Emergency Key override Tabular key lock Electronic key with 4 digits password. Display unit Normal dot matrix LCD Graphic LCD with blue backlit

1. Comparison with existing controller(2) Features/Spec. K-series I-CASS Ethernet No On board Ready GSM

1. Comparison with existing controller(2) Features/Spec. K-series I-CASS Ethernet No On board Ready GSM SMS No Ready Alarm monitoring Based on TTL input on every controller only 2 supervised sensor points on every door Fire alarm No Fire alarm for emergency door release Guard Tour No Available on every door ready as checking terminal. Auxiliary Output Available

1. Comparison with existing controller(3) Feature/Spec. K-series I-CASS Speed 8 Hz 24 MHz User

1. Comparison with existing controller(3) Feature/Spec. K-series I-CASS Speed 8 Hz 24 MHz User storage 5, 000 users 20, 000 users Transaction storage 2, 500 50, 000 users Door connection Max. 8 doors Max. 32 doors Processor 8 bits MCU 16 bits MCU RAM 128 K Byte 2 M byte

1. Comparison with existing controller(4) Feature/Spec. K-series I-CASS Short Messaging Service No Available among

1. Comparison with existing controller(4) Feature/Spec. K-series I-CASS Short Messaging Service No Available among door readers Door release time zone No Available on every door setting Lock out mode No Available on every door setting Emergency duress alarm Available General purpose relay output No Available on controller Software 32 bits Smart. Guard series software 32 bits Smart. Guard ICASS software

1. Level of Changes Existing System 19200 bps I-CASS System 1024 KB 8 6

1. Level of Changes Existing System 19200 bps I-CASS System 1024 KB 8 6 Mhz 2 Mhz 3 32 9600 bps 16 60% more 40% 128 KB Bus Onboard UART Frequency RAM Size Comm. Speed Over all Door Connection Features Comparison with Castle-S/K/T&Commando System

1. System Component(1) • • • I-CASS controller Smart. Box (Door Interface Unit) Door

1. System Component(1) • • • I-CASS controller Smart. Box (Door Interface Unit) Door Reader Electronic Key Power Supply PC interface (PCI) Smart. Guard I-CASS v 5. 6 Used as real time processing unit for all door event and alarm. As card user databases storage. As log transactions storage. Used for all the user setting. Responsible for all the communication bus polling.

1. System Component(2) Smart. Box-Door Interface Unit • Used to control the electronic door

1. System Component(2) Smart. Box-Door Interface Unit • Used to control the electronic door lock device, door contact and lock release button. • Used as reader interface communication gateway to controller. • Perform basic door controlling function during system controller breakdown.

1. System Component(3) I-CASS Reader Interface • Act as reader interface for proximity reader.

1. System Component(3) I-CASS Reader Interface • Act as reader interface for proximity reader. • Mifare® serial number interfacing. • Wiegand 26 bits interfacing. • Keypad and LCD interfacing. • Perform card number conversion. • Display informative message. • PIN generator • Alarm arming and disarming interface panel

1. System Component(4) Electronic Key • Connected to reader interface board • Used during

1. System Component(4) Electronic Key • Connected to reader interface board • Used during emergency breakdown to over-ride the door lock. • Security key is stored with a standard encryption technique. • 10 digits key with suitable password to release door lock.

1. System Component(5) PC Interface Unit (PCI) • Used as a gateway for controller

1. System Component(5) PC Interface Unit (PCI) • Used as a gateway for controller uplink and PC communication port. • Used as a signal converter for RS 232 to RS 485 communication. • Act as a software security key for software version determination.

1. System Component(6) Smart. Guard –ICASS v 5. 6 • 32 bits PC software.

1. System Component(6) Smart. Guard –ICASS v 5. 6 • 32 bits PC software. • Act as a interface software for data or user setting downloading machine. • Act as log transaction uploading software for data reporting purpose. • Time attendance report generation.

1. System Configuration(1) BUS 4 BUS 3 I-CASS Controller RS 485 RS 232 PC

1. System Configuration(1) BUS 4 BUS 3 I-CASS Controller RS 485 RS 232 PC I BUS 2 PC Interface I-Cass Software BUS 1 2 Wires Door Interface (1) Door Interface (2) Maximum 8 doors (expandable) Door Interface (3) Door Interface (4) Door Interface (5) Push Button In Reader Lock System E-Key RS 485 RS 232 E-Key Out Reader Magnetic Sensor

1. I-Cass Features Proximity Technology ABS Casing LCD Screen SMS Press Alarm Guard Tour

1. I-Cass Features Proximity Technology ABS Casing LCD Screen SMS Press Alarm Guard Tour Alarm Systems Time Attendance Polycarbonate Keypad Networking E - Key

1. Features Highlighted (1) • Enable Short Message Service (SMS) • Inbound System Preset

1. Features Highlighted (1) • Enable Short Message Service (SMS) • Inbound System Preset greetings or short messages SMS Employees • Outbound System Doors forced open or burglary SMS Owner Ø Storage Capacity: 100 users with 50 characters each user.

1. Features Highlighted (2) • Guard Tour Feature 1. Configuration Door 1 Time set

1. Features Highlighted (2) • Guard Tour Feature 1. Configuration Door 1 Time set : 10 mins Main Door 2 Door 3 Time set : 20 mins Back Off Door 2 “Beep” Door 3 2. He/She did not proceed to Door 2 Door 1 Time set : 10 mins Time set : 20 mins Back Main Off 3. He/She did not proceed to Door 3 Door 1 Main Time set : 10 mins Door 2 Back Time set : 20 mins Door 3 “Beep” Off

1. Features Highlighted (3) • Controller storage capacity : • Standard 20, 000 users.

1. Features Highlighted (3) • Controller storage capacity : • Standard 20, 000 users. • Expandable to 100, 000 users • Event Transaction Storage Capacity: • Maximum 30, 000 events • Multi door Anti-pass back. • Multi door Interlocking • On board alarm input and output point. • Dual Card Mode.

1. Features Highlighted (4) • • • Access Counter. Time Zone Control Door Release

1. Features Highlighted (4) • • • Access Counter. Time Zone Control Door Release Button 2 Holiday Groups @ 50 settings per group. Software Configurable to general purpose relay output. Enable to Interface with CIA 88 additional alarm input or output point. • Maximum 32 doors linkage per controller. • • • Keypad arming on every door. Controller backup. Electronic Key (E-Key) for emergency door release. Support K series feature. On board Ethernet. Graphic LCD.

1. ~ The End ~ ~ Thank you ~ Visit our website: www. castle.

1. ~ The End ~ ~ Thank you ~ Visit our website: www. castle. com. my for more information.