HEATING COOLING WATER HEATING PRODUCTS 2015 Commercial Products

  • Slides: 38
Download presentation
HEATING, COOLING & WATER HEATING PRODUCTS 2015 Commercial Products

HEATING, COOLING & WATER HEATING PRODUCTS 2015 Commercial Products

Commercial - Terminology Commercial General Terminology 3 Phase AHRI Package Units (RTU) Package Gas

Commercial - Terminology Commercial General Terminology 3 Phase AHRI Package Units (RTU) Package Gas Electric Package Air Conditioner Package Heat Pump Split System Split Air Conditioner Split Heat Pump Air Handler Furnace Coil Accessory Roof Curb Adapter Economizer Fresh Air Damper Controls DDC BMS, EMS, BAS Bacnet, Lon. Works, Modbus Commercial Component Terminology Compressor Indoor Fan Motor Indoor Fan Blower Sheaves/Pulleys Outdoor Fan Motor Outdoor Fan Indoor Coil Outdoor Coil Refrigerant Control – TXV Controls Capacitor Transformer Microprocessor Control Contactor Heat Exchanger Inducer Gas Valve Igniter Flame Sense Burner Cabinet Commercial Application Terminology Equipment Schedule Airflow Supply/Return/Fresh/Mixed Air CFM Capacity(Total, Latent, Sensible) Tonnage BTU Efficiency (SEER, IEER) Voltage MCA Gas Heat Electric Heat Hot Gas Reheat Cooling Load/Heat Load Occupied/Unoccupied Static (external) Temperature (Dry bulb, Wet bulb) Entering/Leaving Conditions Ambient Humidity Building Type Ask yourself if you have a general understanding of Terminology?

Efficiency Terminology • SEER – is the ratio of cooling in British thermal unit

Efficiency Terminology • SEER – is the ratio of cooling in British thermal unit (BTU) to the energy consumed in watt-hours during a typical cooling season. – < 65 K BTUH • EER – Same as SEER at a single point – 95/80/67 – >65 K BTUH • IEER

Commercial – Government Regulation Note: Applies to Single-Phase Models Only

Commercial – Government Regulation Note: Applies to Single-Phase Models Only

Points of Interest – Micro Channel • Used on RKKL/RLKL and RKRL/RLRL models •

Points of Interest – Micro Channel • Used on RKKL/RLKL and RKRL/RLRL models • Replaces conventional condenser design • All aluminum design • 25 year proven automotive application • Benefits • Superior heat transfer in smaller size • Up to 50% less refrigerant • All Aluminum design: durable surface, resists damage, easy to recycle • Weighs less

Tube & Fin versus Micro Channel Tubes Mechanically Connected to Fins • Tube is

Tube & Fin versus Micro Channel Tubes Mechanically Connected to Fins • Tube is expanded into fin • Less thermal efficiency vs. brazed Tubes Metallurgic ally Bonded to Fins • Entire assembly brazed in furnace • Superior thermal efficiency Tube & Fin Design MCHX Design

Tube & Fin versus Micro Channel • Thin tubes • Less obstruction To Airflow

Tube & Fin versus Micro Channel • Thin tubes • Less obstruction To Airflow • Less Fan power • Improved energy Efficiency Airflow • Internally webbed • Tubes • Improved Strength • Increased surface area • Improved Thermal efficiency • Larger Tubes • More obstruction To airflow • More fan power • Less energy efficiency Refrigerant Flow Tube & Fin Design MCHX Design

Micro-Channel Coils Cleaning • Water • p. H Neutral Cleaner • High Pressure Washer

Micro-Channel Coils Cleaning • Water • p. H Neutral Cleaner • High Pressure Washer • Not more than 900 psi • At least 12” from coil • < 45⁰ Angle Tech Tip: Use of alkaline or acid based cleaners may have an adverse impact on the coil coating.

Micro-Channel Coils Repair • Leak – Fin Pack • Kit PD 875491 • Leak

Micro-Channel Coils Repair • Leak – Fin Pack • Kit PD 875491 • Leak – Other Locations • Replace Coil Assembly • Copper Stub Tubes Provided • No Brazing Aluminum

Micro-Channel Key Advantages • • Competitive performance Resistant to formicary corrosion Improved design and

Micro-Channel Key Advantages • • Competitive performance Resistant to formicary corrosion Improved design and reliability • Fewer braze joints than before, which lowers the opportunities for leaks Less tube rubbing • No capillary tube connections on the coil, lowering the possibility of leaks due to tubes rubbing together Less Refrigerant required for service • New models up to 55% less refrigerant than current models Less weight • Up to 10% lighter than current models Simplified replacements • Same footprint as current product line Easy on your pocket – no change in price from current line

Product Depth – Up to 3 Tiers/12 Families to Fit All Commercial Needs Commercial

Product Depth – Up to 3 Tiers/12 Families to Fit All Commercial Needs Commercial Series – Tier 1 • • Up to 13 EER Package Gas Electric and Package Air Conditioners with Clear Control and VFD Standard Clear Control, ¼ turn fasteners and hinged access, TXV 5 Year Compressor, 1 Year Parts Warranty Commercial Series – Tier 2 • • • Up to 11. 2 EER Package Gas Electric, Package Air Conditioners, Package Heat Pumps, Condenser, Heat Pumps, Air Handlers Standard ¼ turn fasteners and hinge access, TXV Reheat, Clear Control, VFD available factory options 5 Year Compressor, 1 Year Parts Warranty Commercial Series – Tier 3 • • Up to 11. 2 Package Gas Electric, Package Air Conditioners, Package Heat Pumps Fixed access and fixed refrigerant control 5 Year Compressor, 1 Year Parts Warranty

Competitor Overview: Product Positioning

Competitor Overview: Product Positioning

Commercial Package Selling Points Complete Commercial Package and Split Line 3 to 6 ton;

Commercial Package Selling Points Complete Commercial Package and Split Line 3 to 6 ton; PGE, PAC 6 to 12 ½ ton; PGE, PAC 15 to 25 ton; PGE, PAC 3 to 15 ton; PHP 3 to 20 ton; Split AC 3 to 10 ton; Split HP Market Share: 4 year history of year over year Market Share increase Right product, Right price, Right distribution Reliability: National recognized quality leader Efficiency: 2 Levels of efficiency: 13 and 14 SEER or 11. 2 and 13 EER Capacity: Strong nominal capacities 3 thru 25 tons Cabinet Size: Competitive size and weights Price: Competitive price in each category

Res / Light Comm Platform Package Gas Electric RGEA 13 13 SEER (1 PH)

Res / Light Comm Platform Package Gas Electric RGEA 13 13 SEER (1 PH) RGEA 14 14 SEER RGEA 15 15 SEER RGEA 16 16 SEER Package Air Conditioners RACA 13 13 SEER (1 PH) RACA 14 14 SEER RACA 15 15 SEER Cooling Capacities PGE and PAC: 6 Capacities (2 - 5 Ton) PHP: 5 Capacities (2 – 4 Ton) Heating Capacities Gas Heat Inputs (40 -100 Kbtuh) Electric Heat Inputs (5 -15 Kw) Voltages 208/230 Volt Single & Three Phase 460 Volt Three Phase Cabinet Sizes 47 5/8 x 50 7/8 x 35 5/16 (Wx. Lx. H) 47 5/8 x 50 7/8 x 41 (Wx. Lx. H) Package Heat Pumps RQNL 13 SEER (1 PH) RQPL 14 SEER RQPW 14 SEER Standard Features 100% Scroll Louver Coil Protection Powder Coat Paint High and Low Pressure External Gauge Ports Convertible Airflow

Product Positioning Matrix Res / Light Comm Platform Rheem Carrier Trane York Goodman TIER

Product Positioning Matrix Res / Light Comm Platform Rheem Carrier Trane York Goodman TIER 1 Prestige Series RGEA 16 2, 3, 4 and 5 Ton Up to +16 SEER Up to +12 EER 10 Yr. comp. 10 Yr. Parts L. L. Heat Exchanger Infinity 48 VG/50 VR (-A) 16 SEER 2 -5 Ton 10 Yr. Comp 5 Yr. Parts L. L. on S. S. XL 16 C 4 YCZ/4 WCZ 16 SEER 3, 4, 5 Ton 10 Yr. Comp 5 Yr. Parts 20 Yr. Heat Exchanger Affinity DNX/DEX/BHX: Up to 16. 5 SEER Up to 12 EER 2 -4 ton 10 Yr. Comp 5 Yr. Parts 20 Yr. Heat Exchanger GPG 1515 M/GPH 15 M Up to 15 SEER 2 to 5 ton 10 Yr. Parts Not Available TIER 2 Classic Series RGEA 15/RACA 15 RRPL/RSPL/RQPL 15 SEER Up to 12 EER 2 -5 Tons 10 Yr. Comp 10 Yr. Part L. L. on S. S. Classic Series RGEA 14/RACA 14/ RQPL – 14 SEER RGEA 13/RACA 13/ RQNL - 13 SEER (1 ph) 2 -5 Ton 10 Yr. Comp 10 Yr. Parts 20 Yr. Heat Exchanger L. L. on S. S. Comfort 48 VL/50 VT (-A) 14 SEER 48 ES/50 EZ (-A) 13 SEER (1 PH) 2 -5 Ton 10 Yr. Comp 5 Yr. Parts XL 14 C 4 YCY/4 TCY/4 WCY 14 SEER XL 13 C/XB 13 C 4 YCC/4 TCC/4 WCC 13 SEER (1 PH) 2 -5 Ton 10 Yr. Comp 5 Yr. Parts 20 Yr. Heat Exchanger Affinity DNQ/DEQ/DNY/BHQ: 14 SEER DNZ/DEEZ/BHZ: R 410 A 13 SEER 2 -5 Ton 10 Yr. Comp 5 Yr. Parts 20 Yr. Heat Exchanger GPG 14 M/GPC 14 M/ GPH 14 M 14 SEER GPG 13 M/GPC 13 M/ GPH 13 M 13 SEER 2 -5 Ton 10 Yr. Parts TIER 3

Commercial Package Platform Package Gas Electric RKNN – 13 SEER (R 410 A) RKPN

Commercial Package Platform Package Gas Electric RKNN – 13 SEER (R 410 A) RKPN – 14 SEER (R 410 A) RKQN – 15 SEER (R 410 A) Package Air Conditioners RLNN – 13 SEER (R 410 A) RLPN – 14 SEER (R 410 A) RLQN – 15 SEER (R 410 A) Cooling Capacities 4 Capacities (3 – 5 Ton) Heating Capacities Heat Inputs (80 - 135 Kbtuh) Heat Inputs (5 – 20 Kw) Voltages 208/230 Volt Single & Three Phase 460 Volt Three Phase Cabinet Size 48 1/8 x 76 1/4 x 35 (Wx. Lx. H) Standard Features 100% Scroll Louver Coil Protection* Powder Coat Paint Direct or Belt Drive High and Low Pressure External Gauge Ports Convertible Airflow Factory Options Package Heat Pumps RJNL – 13 SEER (R 410 A) RJPL – 14 SEER (R 410 A)

ID Coil Comparison New Micro Channel Evaporator • • • Micro Channel is an

ID Coil Comparison New Micro Channel Evaporator • • • Micro Channel is an ALL Aluminum design TXV feeds into 3/8” line Circulating inside manifolds Old Cu tube/Al fin Evaporator • • • Formicary corrosion attacks copper TXV feeds into distributors that may rub other tubes Circulating on outside of coil

OD Coil Comparison Old Cu tube/Al fin Condenser Multiple braze joints Opportunities for leaks

OD Coil Comparison Old Cu tube/Al fin Condenser Multiple braze joints Opportunities for leaks New Micro Channel Condenser Only 2 braze joints Lower opportunities for leaks

Less Charge/Less Weight Cu tube/Al fin Evaporator Cu tube/Al fin Condenser RKNL (3 ton)

Less Charge/Less Weight Cu tube/Al fin Evaporator Cu tube/Al fin Condenser RKNL (3 ton) RKNN (3 ton) Micro-Channel Evaporator RKNL (4 ton) RKNN (4 ton) Micro-Channel Condenser RKNL (5 ton) RKNN (5 ton) R 410 A lbs. 6. 0 3. 4 10. 3 4. 3 9. 2 3. 9 Cond. lbs. 34 20. 5 66. 5 23 Evap. lbs. 24. 5 23 36 24 36 27

Same Footprint/Same Accessories Options Current Models New Models Notes: Ø No change to footprint

Same Footprint/Same Accessories Options Current Models New Models Notes: Ø No change to footprint or cabinet Ø Accessories will remain the same as current for the new product, except: • • Economizers with updated communicating controls and smoke detection • From W 7415 to New Jade Control with low leak air foil blade Hail Guard (3 ton only) – new micro-channel coil is smaller, requiring only a 2 sided hail guard

Curb Adapters Carrier/Bryant/ICP to Rheem Roofcurb Adapter - RXRX-EACC 35 Packaged G/E 48 DJ*004

Curb Adapters Carrier/Bryant/ICP to Rheem Roofcurb Adapter - RXRX-EACC 35 Packaged G/E 48 DJ*004 - 007 48 GJ*006 48 HE*003 - 006 48 HJ*004 - 007 48 HM*007 48 LJ*004 - 007 48 TC*004 - 007 48 TF-004 - 007 48 TJ*004 - 007 48 TM*004 - 007 Carrier Models Packaged AC 50 DJ 004 - 007 50 GJ 006 50 HE 003 - 006 50 HJ 004 - 007 50 HM 007 50 LJ 004 - 007 50 TC 004 - 007 50 TFF 004 - 007 50 TJ 004 - 007 50 TM 004 - 007 Packaged G/E PGE 036 – 072 PGH 036 – 072 PGS 072 RGS 036 – 072 ICP Models Packaged AC PAE 036 – 072 PAH 036 – 072 PAS 072 RAS 036 - 072 Packaged HP 50 QJ 004 -006 50 HEQ 003 - 006 50 HJQ 004 - 007 50 LJQ 004 - 006 50 TCQ 004 - 007 50 TFQ 004 - 007 50 TJQ 004 - 007 Packaged HP PHE 072 PHH 036 – 072 PHS 072 RHS 036 – 072 Packaged G/E 581 A*V 036 – 072 581 B*V 036 – 072 580 C*V 036 – 072 580 D*V 036 – 072 580 F*V 036 -072 580 J*04 - 07 Bryant Models Packaged AC 551 A*X 036 – 072 551 B*X 036 – 072 558 C*X 036 – 0720 558 D*X 036 – 072 558 F*X 036 – 072 558 J*04 – 07 Packaged HP 549 B*X 036 – 072 548 C*X 036 – 060 548 D*X 036 – 072 548 F*X 036 – 072 548 J*04 – 07

Curb Adapters Trane to Rheem Roofcurb Adapter – RXRX-EACT 35 Packaged G/E YCD-036, 037,

Curb Adapters Trane to Rheem Roofcurb Adapter – RXRX-EACT 35 Packaged G/E YCD-036, 037, 048, 049, 060 Packaged AC TCD-036, 037, 048, 049, 060 Packaged HP WCD-036, 037, 048, 049, 060

Competitor Overview: Product Positioning Rheem Carrier TIER 3 York Energence LGH###S/LCH###S 3 -5 ton

Competitor Overview: Product Positioning Rheem Carrier TIER 3 York Energence LGH###S/LCH###S 3 -5 ton 17 SEER Up to 12. 8 EER Warranty: 5 yr comp. /1 yr parts TIER 1 TIER 2 Lennox Trane Precedent YHC/THC 3 -5 Ton 17 SEER Warranty: 5 yr comp. /1 yr parts Commercial Series RKQN/RLQN (15 SEER) RKPN/RLPN/RJPL (14 SEER) 3 -5 ton Up to 12. 25 EER Warranty: 5 yr comp. /1 yr parts Weather Master 48 HC/50 HC 3 -5 ton Up to 15. 6 SEER Up to 13 EER Warranty: 5 yr comp. /1 yr parts Energence LGH###S/LCH###S 3 -5 ton 15 SEER Up to 12. 5 EER Warranty: 5 yr comp. /1 yr parts Predator ZH/ZJ 3 to 5 ton 14/15 SEER 11. 8/12. 2 EER Warranty: 5 yr comp. /1 yr parts Precedent YHC/THC 3 -5 ton 15 SEER Warranty: 5 yr comp. /1 yr parts Commercial Series RKNN/RLNN/RJNL 3 -5 ton 13 SEER Warranty: 5 yr comp. /1 yr parts Weather. Maker 48 TC/50 TCQ 3 -5 ton Up to 13 SEER Warranty: 5 yr comp. /1 yr parts Landmark KGA/KCA/KHA 3 -6 ton Up to 13 SEER Warranty: 5 yr comp. /1 yr parts Sunline Magnum ZJ/ZR/ZF: 3 -5 ton 13 SEER Up to 11 EER Warranty: 5 yr comp. /1 yr parts Precedent YSC/TSC/WSC 3 -5 ton 13 SEER Warranty: 5 yr comp. /1 yr parts

Commercial Package Platform Package Gas Electric RKKL – 11. 2 EER (R 410 A)

Commercial Package Platform Package Gas Electric RKKL – 11. 2 EER (R 410 A) RKNL – 11. 2 EER (R 410 A) RKRL – Up To 13 EER (2011) Package Air Conditioners Package Heat Pumps RLKL – 11. 2 EER (R 410 A) RLNL – 11. 2 EER (R 410 A) RLRL – Up to 13 EER (2011) Standard Features 100% Scroll Louver Coil Protection* External Gauge Ports Powder Coat Paint Convertible Airflow Belt Drive Factory Options RJNL – 11 EER (R 410 A) Cooling Capacities RKRL/RLRL 2 Capacities (7 ½ and 10) RKNL/RLNL 5 Capacities (6 – 12 ½ Ton) RKKL/RLKL 4 Capacities (6, 7 ½, 10, 12 ½ Ton) Heating Capacities Gas Heat Inputs (150 – 250 Kbtuh) Electric Heat Inputs (10 – 50 Kw) Voltages 208 / 230 Volt Three Phase 460 Volt Three Phase Cabinet Sizes 58 ¾ x 93 11/16 x 44 (Wx. Lx. H)

Competitor Overview: Product Positioning Rheem TIER 1 Commercial Series RKRL/RLRL R 410 A 7.

Competitor Overview: Product Positioning Rheem TIER 1 Commercial Series RKRL/RLRL R 410 A 7. 5, 10 ton Up to 13 EER Up to 15. 8 IEER Warranty: 5 yr comp. /1 yr parts TIER 2 Commercial Series RKNL/RLNL/RJNL R 410 A 6 to 12 ½ ton Up to 11. 5 EER Up to 13 IEER Warranty: 5 yr comp. /1 yr parts TIER 3 Commercial Series RKKL/RLKL R 410 A 6, 7. 5, 10, 12. 5 ton Up to 11. 2 EER Up to 12. 2 IEER Warranty: 5 yr comp. /1 yr parts Carrier Weather. Master 48 HC/50 HC R 410 A 6 to 12 /12 ton Up to 12. 2 EER Up to 13. 9 IEER Warranty: 5 yr. comp. /1 yr parts Weather. Maker 48 TC/50 TC R 410 A 6 to 12 ½ ton Up to 11. 5 EER Up to 12. 2 IPLV Warranty: 5 yr comp. /1 yr parts Lennox York Trane Energence LGH/LCH R 410 A 7 ½ to 12 ½ Up to 12 EER Up to 13 IEER Warranty: 5 yr comp. /1 yr parts Predator ZJ R 410 A 7 ½ to 12 1/2 Up to 12. 2 EER Up to 14. 9 IEER Warranty: 5 yr comp. /1 yr parts Precedent YHC/THC R 410 A 6 to 10 ton Up to 13 EER Warranty: 5 yr comp. /1 yr parts L Series LGA/LCA/LHA R 410 A 7 ½ to 12 1/2 ton Up to 11. 0 EER Up to 11. 2 IEER Warranty: 5 yr comp. /1 yr parts Predator ZH/XP: R 410 A 6 ½ to 121/2 ton Up to 11. 5 EER Up to 14. 1 IPLV Warranty: 5 yr comp. /1 yr parts Precedent YSC/TSC/WSC R 410 A 7 1/2 to 10 ton (two stage) Up to 11. 2 EER Up to 12. 5 IPLV Warranty: 5 yr comp. /1 yr parts Land. Mark KGA/KCA/KHA R 410 A 7 ½ to 12 1/2 ton Up to 11. 0 EER Up to 11. 2 IEER Warranty: 5 yr comp. /1 yr parts Predator ZF/ZR R 410 A 6 ½ to 12 /12 ton Up to 11. 2 EER Up to 13 IEER Warranty: 5 yr comp. /1 yr parts Precedent YSC/TSC/WSC R 410 A 6 to 10 ton Up to 11. 2 EER Up to 12. 5 IPLV Warranty: 5 yr comp. /1 yr parts

Product Overview Package Gas Electric Package Air Conditioners RKKL – 10/11 EER (R 410

Product Overview Package Gas Electric Package Air Conditioners RKKL – 10/11 EER (R 410 A) RKNL – 10/11 EER (R 410 A) RKRL – Up To 12 EER (2011) RLKL – 10/11 EER (R 410 A) RLNL – 10/11 EER (R 410 A) RLRL – Up To 12 EER (2011) Standard Features 100% Scroll Louver Coil Protection* External Gauge Ports Powder Coat Paint Convertible Airflow Belt Drive Factory Options Package Heat Pumps RJNL – 10. 6 EER (R 410 A) Cooling Capacities RKRL/RLRL 2 Capacities (15 and 20 Ton) RKNL/RLNL 4 Capacities (15, 17 ½, 20, 25 Ton) RKKL/RLKL 2 Capacities (15 and 20 Ton) Heating Capacities Gas Heat Inputs (250 – 400 Kbtuh) Electric Heat Inputs (20 – 75 Kw) Voltage 208 / 230 Volt Three Phase Cabinet Size 58 ¾ x 146 x 50 (Wx. Lx. H) 58 ¾ x 122 x 50 (Wx. Lx. H)

Competitor Overview: Product Positioning Rheem TIER 1 TIER 2 TIER 3 Commercial Series RKRL/RLRL

Competitor Overview: Product Positioning Rheem TIER 1 TIER 2 TIER 3 Commercial Series RKRL/RLRL R 410 A 15 to 20 ton Up to 12. 0 EER Up to 14. 6 IEER Warranty: 5 yr comp. /1 yr parts Carrier Weather. Master 48 HC/50 HC R 410 A 15 to 25 ton Up to 12 EER Up to 13. 8 IEER Warranty: 5 yr comp. /1 yr parts Commercial Series RKNL/RLNL R 410 A 15 to 25 ton Up to 11. 1 EER Up to 13. 4 IEER Warranty: 5 yr comp. /1 yr parts Commercial Series RKKL/RLKL (1 Q 11) R 410 A 15 & 20 ton Up to 11 EER Up to 11. 1 IEER Warranty: 5 yr comp. /1 yr parts Weather. Maker 48 TC/50 TC R 410 A 15 to 25 ton Up to 10. 8 EER Up to 11. 8 IPLV Warranty: 5 yr comp. /1 yr parts Lennox York Energence LGH/LCH R 410 A 13 to 25 ton Up to 12. 0 EER Up to 13 IEER Warranty: 5 yr comp. /1 yr parts Sunline Magnum ZJ R 410 A 15 to 25 ton Up to 12. 4 EER Up to 13. 9 IPLV Warranty: 5 yr comp. /1 yr parts L SERIES LGA/LCA/LHA R 410 A 15 to 25 ton Up to 11. 0 EER Up to 11. 2 IEER Warranty: 5 yr comp. /1 yr parts Sunline Magnum ZF R 410 A 15 to 25 ton Up to 11. 0 EER Up to 12. 9 IPLV Warranty: 5 yr comp. /1 yr parts Land. Mark KGA/KCA/KHA R 410 A 15 to 25 ton Up to 11. 0 EER Up to 11. 2 IEER Warranty: 5 yr comp. /1 yr parts Trane Voyager YC*/TC* (odd numbers) R 410 A 15 to 25 ton Up to 12. 00 EER Warranty: 5 yr comp. /1 yr parts Voyager YC*/TC*/WC* R 410 A 12 ½ to 25 ton Up to 11. 00 EER Up to 12. 61 IPLV Warranty: 5 yr comp. /1 yr parts

RKKL / RLKL vs. RKNL / RLNL RKKL / RLKL – – – –

RKKL / RLKL vs. RKNL / RLNL RKKL / RLKL – – – – 1 st cool / 2 st heat Fixed Panels Fixed orifice Micro channel cond Slide out filters Slide out drain Slide out blower RKNL / RLNL 7. 5 & 10 Ton – – – – RKKL / RLKL – – – – 2 st cool / 2 st heat Fixed Panels Fixed orifice Micro channel cond Slide out filters Slide out drain Slide out blower 2 st cool / 2 st heat Hinged Panels TXV Cu / Al cond Slide out filters Slide out drain Slide out blower RKNL / RLNL 15 & 20 Ton – – – – 2 st cool / 2 st heat Hinged Panels TXV Cu / Al cond Slide out filters Slide out drain Slide out blower

Competitive Landscape Model Cooling Performance EER AHRI Rated CFM AHRI Net Cooling Capacity Btu

Competitive Landscape Model Cooling Performance EER AHRI Rated CFM AHRI Net Cooling Capacity Btu IEER/IEER with VFD Compressor No. /Type Refrigerant Control Weights Net Weight Dimensions Height Width Length Model Cooling Performance EER AHRI Rated CFM AHRI Net Cooling Capacity Btu IEER Compressor No. /Type Refrigerant Control Weights Net Weight Dimensions Height Width Length Rheem RKRL-C 090 Carrier 48 HC 08 Trane YHC 092 Lennox LGH 092 York ZJ 090 13. 0 2, 600 92, 000 14/15. 8 12. 0 not avail. 89, 000 13/13. 8 12. 6 2, 625 89, 000 15 12. 5 2, 800 90, 000 12. 9/14 12. 0 2, 400 90, 000 13. 1/- 2/Scrolls TXV 2/Recips. TXV 1, 093 925 1, 026 1, 168 1, 050 44. 0 58. 8 93. 7 49. 4 59. 5 88. 1 50. 9 63. 1 99. 7 46. 9 60. 1 101. 3 50. 8 59. 0 89. 0 Rheem RKRL-C 120 Carrier 48 HC 012 Trane YHC 120 Lennox LGH 120 York ZJ 120 12. 5 3, 575 120, 000 13. 8/15. 6 12. 0 not avail. 115, 000 12/12. 4 12. 5 3, 500 113, 000 14/14. 5 12. 0 3, 300 118, 000 13/13. 8 12. 0 3400 120000 12. 2/- 2/Scrolls TXV 2/Scrolls TXV 1, 242 1, 099 1, 369 1, 210 1, 070 50. 0 58. 8 93. 7 49. 4 59. 5 88. 1 50. 9 63. 1 99. 7 46. 9 60. 1 101. 3 50. 8 59. 0 89. 0 Model Cooling Performance EER AHRI Rated CFM AHRI Net Cooling Capacity Btu IEER Compressor No. /Type Refrigerant Control Weights Net Weight Dimensions Height Width Length Rheem RKRL-C 180 Carrier 48 HC 017 Trane YC*181 Lennox LGH 180 York ZJ 180 12. 2 5, 500 174, 000 13. 2/15 12. 0 not avail. 174, 000 13/13. 5 12. 0 5, 300 172, 000 13. 3/14. 2 12. 0 5, 250 172, 000 13/13. 7 12. 4 6, 000 178, 500 14/- 2/Scrolls TXV 2/Scrolls Fixed 3/Scrolls TXV 4/Scrolls TXV 2, 147 1, 829 2, 203 2, 220 2, 609 57. 0 85. 9 125. 1 49. 4 86. 4 127. 9 64. 1 84. 1 121. 7 55. 0 91. 0 133. 0 52. 6 92. 0 180. 6 Rheem RKRL-C 240 Carrier 48 HC 024 Trane YC*241 Lennox LGH 240 York ZJ 240 12. 0 7, 375 232, 000 13. 2/15 12. 0 not avail. 236, 000 13. 2/13. 8 11. 0 7, 000 242, 000 11. 7/13. 1 12. 0 6, 400 230, 000 13. 2/14. 5 11. 5 6, 200 235, 000 13/- 2/Scrolls TXV 4/Scrolls TXV 2, 251 2, 247 2, 129 2, 430 2, 697 57. 0 85. 9 152. 1 57. 4 86. 4 141. 5 64. 1 84. 1 121. 7 55. 0 91. 0 133. 0 52. 6 92. 0 180. 6

Commercial Split System Platform Cooling Capacities 6 Capacities (6 1/2 -20 Ton) Heating Capacities

Commercial Split System Platform Cooling Capacities 6 Capacities (6 1/2 -20 Ton) Heating Capacities Heat Inputs (20 – 75 Kw) Voltages 208/230 Volt Three Phase 460 Volt Three Phase Cabinet Size 31 x 43 x 33 (Wx. Lx. H) 38 3/8 x 60 1/2 x 44 3/4 (Wx. Lx. H) 38 3/8 x 83 7/8 x 44 3/4 (Wx. Lx. H) Condensing Units RAWE/RAWL/RHGL – Up to 11. 2 EER (R 410 A) Standard Features 100% Scroll Louver Coil Protection External Gauge Ports Powder Coat Paint Low Ambient High and Low Pressure Service Valves

Commercial Split System Platform Heat Pump and Air Handlers Units RPWL/RHGM – 11. 0

Commercial Split System Platform Heat Pump and Air Handlers Units RPWL/RHGM – 11. 0 EER (R 410 A) Cooling Capacities 2 Capacities (7 ½ & 10 Ton) Heating Capacities Heat Inputs (20 – 75 Kw) Voltages 208/230 Volt Three Phase 460 Volt Three Phase Cabinet Size 31 1/8 x 42 11/16 x 48 13/16 (Wx. Lx. H) 38 3/8 x 60 1/2 x 44 3/4 (Wx. Lx. H) Standard Features 100% Scroll Louver Coil Protection External Gauge Ports Powder Coat Paint Low Ambient High and Low Pressure

Competitor Overview: Product Positioning Rheem TIER 1 Commercial Series RAWL match w/ RHGL R

Competitor Overview: Product Positioning Rheem TIER 1 Commercial Series RAWL match w/ RHGL R 410 A 6 to 20 ton Up to 11. 2 EER Warranty: 5 yr comp. /1 yr parts Rheem TIER 1 Commercial Series RPWL match w/ RHGM R 410 A 7 ½ and 10 ton 11. 2 EER Warranty: 5 yr comp. /1 yr parts Carrier Gemini 38 AUZ match w/ 40 RU R 410 A 6 to 20 ton Up to 11. 2 EER Warranty: 5 yr comp. /1 yr parts Carrier Gemini 38 AQUZ match w/ 40 RU R 410 A 6 to 20 ton Up to 11. 2 EER Warranty: 5 yr comp. /1 yr parts Lennox T-Class TSA match w/ TAA R 410 A 6 to 20 ton Up to 11. 2 EER Warranty: 5 yr comp. /1 yr parts Lennox T-Class TPA match with TAA R 410 A 7 ½ and 10 ton Up to 11. 0 EER Warranty: 5 yr comp. /1 yr parts York Predator YC/YD match w/ NC/ND R 410 A 6 to 20 ton Up to 11. 2 EER Warranty: 5 yr comp. /1 yr parts York Predator PC/PD match w/ NC/ND R 410 A 6 to 20 ton Up to 11. 2 EER Warranty: 5 yr comp. /1 yr parts Trane Odyssey TTA match w/ TWE R 410 A 6 to 20 ton Up to 11. 2 EER Warranty: 5 yr comp. /1 yr parts Trane Odyssey TWA match w/ TWE R 410 A 6 to 20 ton Up to 11. 2 EER Warranty: 5 yr comp. /1 yr parts

Points of Interest – Classic RTU • Meets federal minimum efficiency (ASHRAE 90. 1

Points of Interest – Classic RTU • Meets federal minimum efficiency (ASHRAE 90. 1 -2010) 7 ½ and 10 ton • Micro Channel coil technology uses up to 50% less refrigerant than conventional coils • Mechanically fastened access panels • Fixed restriction refrigerant control 15 to 20 ton

Points of Interest – Classic Plus RTU • Meets federal minimum efficiency (ASHRAE 90.

Points of Interest – Classic Plus RTU • Meets federal minimum efficiency (ASHRAE 90. 1 -2010) • Clear Control (DDC) standard and can easily be expanded to third party building management systems. 7 ½ to 12 ½ ton • Optional VFD technology for supply fans further enhances energy savings. • Optional Humidi. Dry • ¼ turn fasteners and hinges 15 to 25 ton • TXV refrigerant control

Points of Interest – Prestige RTU 7 ½ and 10 ton 15 to 20

Points of Interest – Prestige RTU 7 ½ and 10 ton 15 to 20 ton • Exceed federal minimum efficiency (ASHRAE 90. 1 -2010) by up to 15%. • Exceed Energy Star requirements by 10%. • Meets Consortium of Energy Efficiency (CEE) unitary air conditioning Tier 2 specification. • Clear Control (DDC) standard and can easily be expanded to third party building management systems. • Micro Channel coil technology uses up to 50% less refrigerant than conventional coils. • Optional VFD technology for supply fans further enhances energy savings.

Commercial Prestige RTU - Product Offering • Commercial Prestige Package Gas Electrics unit model

Commercial Prestige RTU - Product Offering • Commercial Prestige Package Gas Electrics unit model number is RKRL-C. • Commercial Prestige Package Air Conditioners units model number is RLRL-C. • All Prestige Units are two stage cooling with CLEARControl™. • Model number with VFD are RKRL-H or RLRL-H. • Factory options available (see specification). 7 ½ and 10 ton 15 to 20 ton

Competitive Landscape Rheem’s Commercial Prestige Rooftop: • • • Has some of the industry

Competitive Landscape Rheem’s Commercial Prestige Rooftop: • • • Has some of the industry highest EER’s and IEER’s. Has some of the industry highest capacities. Efficiencies are achieved without sacrificing airflow or capacity. Capacity and efficiencies achieved with 50% less refrigerant. Competitive weights and cabinet size.

HEATING, COOLING & WATER HEATING PRODUCTS 2015 Commercial Products

HEATING, COOLING & WATER HEATING PRODUCTS 2015 Commercial Products