HD SIGNAL CONDITIONER SERIES RTD TRANSMITTER MODEL HDRTD

  • Slides: 2
Download presentation
HD SIGNAL CONDITIONER SERIES RTD TRANSMITTER MODEL HD-RTD MODEL & SUFFIX CODE SELECTION MODEL

HD SIGNAL CONDITIONER SERIES RTD TRANSMITTER MODEL HD-RTD MODEL & SUFFIX CODE SELECTION MODEL HD-RTD ■ Input signal ■ Output 1 signal GENERAL SPECIFICATIONS Construction : plug-in Connection : M 3. 5 screw terminals Housing material : flame-resistant resin (black) Isolation : input to output to power (non-isolated between I/O) LCD meter : indicating input; 0. 1% increments Overrange output : approx. -10 - +120% at 1 - 5 V Front adjustments : zero and span ; 5% Burnout protection : upscale standard; downscale optional Linearization : standard ■ Output 2 signal Availability as Output 1 N: None ■ Display A: Percent B: Input signal C: Output signal O: Others N: None INPUT & OUTPUT • INPUT : 2 - or 3 -wire RTDs ■ Power X: 110 V AC Z: 24 V DC Maximum leadwire resistance : 200 per wire (3 -wire) Sensing current : 2 m. A (Pt) Temperature range Y: 220 V AC O: Others ORDERING INFORMATION Specify code number and variables. • Code number : ex) HD-RTD-4 AANY • Temperature range (e. g. 0 - 500℃) • Special input and output ranges : code: 0 A : -10 ~ 20 m. A V : 0 ~ 15 V 1

INSTALLATION ■ OUTPUT • DC Current : 0 - 20 m. A DC Power

INSTALLATION ■ OUTPUT • DC Current : 0 - 20 m. A DC Power input AC : rating 10%, 50/60 2 Hz, approx. 2 VA DC : rating 10% , or 85 - 150 V for 110 V rating (ripple 10% p-p max. ) approx. 2 W (80 m. A at 24 V) Operating temperature : -5 to +60℃ (23 to 140℉) Operating humidity : 30 to 90% RH (non-condensing) Mounting : surface or DIN rail Dimensions : W 50 H 80 D 123 mm See General Spec. Sheet Page B-1. Weight : Terminal assignment : See General Spec. Sheet Page B-1. Minimum span : 1 m. A Zero suppression/elevation : max. 1. 5 times span Load resistance Output Load Resistance 4 2 1 0 0 - 20 m. A 10 m. A 5 m. A 20 m. A 16 m. A 10 m. A 1 m. A : : : : 750 ( maximum) 1500 3000 750 900 15 k PERFORMANCE in percentage of span • DC Voltage : -10 - +12 V DC Minimum span : 5 m. V Zero suppression/elevation : max. 1. 5 times span Load resistance : output drive 10 m. A maximum; 5 m. A for negative voltage output; at 0. 5 V Output Load Resistance 0 0 0 1 - 10 m. V 100 m. V 1 V 10 V 5 V 5 V : : : Accuracy : 0. 2% Temp. coefficient : 0. 015%/℃ ( 0. 008%/℉) Ripple : 0. 25% p-p max. (100/120 Hz) Response time : 0. 4(400 ms) seconds (0 - 90%) approx. 25 milliseconds with option Burnout response : 10 seconds Line voltage effect : 0. 1% over voltage range Insulation resistance : 100 MΩ with 500 V DC Dielectric strength : 1500 V AC @1 minute (RB : input or output to power to ground) (RBS : input to output to power to ground) Common mode voltage : 30 V RMS (CSA) Surge withstand Voltage : 1. 2/50 sec, 5 KV (INPUT to OUTPUT to GROUND) 10 k ( minimum) 100 k 1000 500 SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM 2